• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Detection of Biomolecules Using Volume-Amplified Magnetic Nanobeads

Zardán Gómez de la Torre, Teresa January 2012 (has links)
This thesis describes a new approach to biomolecular analysis, called the volume-amplified magnetic nanobead detection assay (VAM-DNA). It is a sensitive, specific magnetic bioassay that offers a potential platform for the development of low-cost, easy-to-use diagnostic devices. The VAM-NDA consists of three basic steps: biomolecular target recognition, enzymatic amplification of the probe-target complex using the rolling circle amplification (RCA) technique, and addition of target complementary probe-tagged magnetic nanobeads which exhibit Brownian relaxation behavior. Target detection is demonstrated by measuring the frequency-dependent complex magnetization of the magnetic beads. The binding of the RCA products (target DNA-sequence coils) to the bead surface causes a dramatic increase in the bead size, corresponding essentially to the size of the DNA coil (typically around one micrometer). This causes a decrease in the Brownian relaxation frequency, since it is inversely proportional to the hydrodynamic size of the beads. The concentration of the DNA coils is monitored by measuring the decrease in amplitude of the Brownian relaxation peaks of free beads. The parameters oligonucleotide surface coverage, bead concentration, bead size and RCA times were investigated in this thesis to characterize features of the assay. It was found that all of these parameters affect the outcome and efficiency of the assay. The possibility of implementing the assay on a portable, highly sensitive AC susceptometer platform was also investigated. The performance of the assay under these circumstances was compared with that using a superconducting quantum interference device (SQUID); the sensitivity of the assay was similar for both platforms. It is concluded that, the VAM-NDA opens up the possibility to perform biomolecular detection in point-of-care and outpatient settings on portable platforms similar to the one tested in this thesis. Finally, the VAM-NDA was used to detect Escherichia coli bacteria and the spores of Bacillus globigii, the non-pathogenic simulant of Bacillus anthracis. A limit of detection of at least 50 bacteria or spores was achieved. This shows that the assay has great potential for sensitive detection of biomolecules in both environmental and biomedical applications.
2

Molecular Diagnostics Using Volume-Amplified Magnetic Nanobeads : Towards the Development of a Novel Biosensor System

Strömberg, Mattias January 2009 (has links)
Micro- or nanometer sized magnetic particles (beads) currently have a vast range of life science applications in, for example, bioseparation techniques, cancer therapy, development of contrast agents and biosensing techniques. In the latter field, magnetic beads offer several unique advantages, including minimal background signals, physical and chemical stability and low manufacturing costs. Because of these properties, magnetic biosensing techniques are potential candidates for low-cost, easy-to-use molecular diagnostic devices. This doctoral thesis focuses mainly on the proof of principle and further development of a new magnetic biosensor platform for detection of DNA targets, a potential candidate for a new generation of low-cost, easy-to-use diagnostic devices: the Volume-Amplified Magnetic Nanobead Detection Assay (VAM-NDA). The VAM-NDA principle combines target recognition by padlock probe ligation followed by rolling circle amplification (RCA) of the reacted probes with changes in Brownian relaxation behaviour of magnetic nanobeads (typically ~100 nm in diameter) induced by a change in hydrodynamic bead volume. More specifically, the RCA products (coils, typically ~1 μm in diameter) are detected magnetically by adding magnetic beads tagged with detection probes complementary to part of the repeating RCA-coil sequence. Thus, depending on the target concentration, a certain quantity of beads binds to the coils by base-pair hybridisation (bead immobilisation), resulting in a dramatic bead volume increase, which is then detected by measuring the complex magnetisation spectrum. Use of a commercial SQUID magnetometer for measuring complex magnetisation resulted in a detection limit in the low pM range for DNA targets with excellent quantification accuracy. Simultaneous multiplexing was also evaluated. The stability and aging of typical commercial ferrofluids (suspensions of magnetic beads) were investigated by measuring the complex magnetisation of and interbead interactions in oligonucleotide-functionalised ferrofluids. In summary, the bead surface characteristics were found to have a strong impact on the measured dynamic magnetic properties.
3

The fabrication process of microfluidic devices integrating microcoils for trapping magnetic nano particles for biological applications / Procédé de fabrication de dispositifs microfluidiques intégrant des microbobines – Piégeage de nanoparticules magnétiques pour des applications en biologie

Cao, Hong Ha 21 July 2015 (has links)
Le but de cette étude est de concevoir, fabriquer et caractériser une puce microfluidique afin de mettre en oeuve la capture de nanoparticules magnétiques fonctionnalisées en vue de la reconnaissance d’anticorps spécifiques (couplage d’une très grande spécificité et sensibilité). Après avoir modélisé et simulé les performances de la microbobine intégrée dans le canal de la puce microfluidique en prenant soin de limiter la température du fluide à 37°C, la capture devant être effective, le microsystème est fabriqué en salle blanche en utilisant des procédés de fabrication collective. La fabrication du microdispositif en PDMS a aussi donné lieu à l’optimisation de procédés de modification de surface afin d’assurer la ré-utilisation du microdispositif (packaging réversible) et la limitation de l’adsorption non spécifique. L’immobilisation des anticorps su les billes (300 nm) a été menée à l’intérieur du canal en utilisant un protocole de type ELISA éprouvé. Le procédé a montré qu’il était également efficient pour cet environnement puisque nous avons pu mettre ne évidence la capture de nanoparticules / In this study, a concept of microfluidic chip with embedded planar coils is designed and fabricated for the aim of trapping effectively functionalized magnetic nanobeads and immobilizing antibody (IgG type). The planar coils as a heart of microfluidic chip is designed with criterion parameters which are optimized from simulation parameters of the maximum magnetic field, low power consumption and high power efficiency by FE method. The characterization of microcoils such as effectively nanobeads (300 nm) at low temperature (<37oC) is performed and confirmed. The channel network in PDMS material is designed for matching with entire process (including mixing and trapping beads) in microfluidic chip. A process of PDMS’s surface modification is also carried out in the assemble step of chip in order to limit the non-specific adsorption of many bio substances on PDMS surface. The microfluidic chip assemble is performed by using some developed techniques of reversible packaging PDMS microfluidic chip (such as stamping technique, using non-adhesive layer, oxygen plasma combining with solvent treatment). These packaging methods are important to reused microchip (specially the bottom substrate) in many times. The immobilization of antibody IgG-type is performed inside microfluidic chip following the standard protocol of bead-based ELISA in micro test tube. The result showed that IgG antibodies are well grafted on the surface of carboxyl-beads (comparing to result of standard protocol); these grafted antibodies are confirmed by coupling them with labeled second antibody (Fab-FITC conjugation).

Page generated in 0.046 seconds