• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Couches minces de ferrites spinelles à propriétés semiconductrices destinées à la réalisation de microbolomètres

Capdeville, Stéphanie 04 February 2005 (has links) (PDF)
Les conditions d'élaboration de couches minces de ferrites riches en zinc ont été étudiées en vue de leur intégration comme matériau thermomètre dans des microbolomètres. La pulvérisation cathodique radiofréquence s'est avérée assimilable à un traitement à haute température sous faible pression d'oxygène. La modification judicieuse des conditions de dépôt a permis de limiter les phénomènes de réduction, évitant ainsi la formation de l'oxyde mixte fer-zinc de type wustite. Toutefois, les ferrites obtenus sont déficitaires en oxygène et présentent une température de Curie anormalement élevée. L'évolution de la porosité des films a été établie en fonction des paramètres de dépôt utilisés. Des mesures d'impédance complexe ont révélé que les zones intergranulaires gouvernaient la conduction; leur résistivité augmentant avec la porosité des couches minces. Des recuits sous air et des changements de l'ordre magnétique ont également permis de modifier les propriétés électriques des films.
2

Mesure d’impédance acoustique pour la caractérisation des cycles limites de moteurs thermoacoustiques / Acoustic impedance measurement to caracterize thermoacoustic engines limit cycles

Zorgnotti, Valentin 18 January 2019 (has links)
Ce manuscrit de doctorat propose une méthode expérimentale pour la caractérisation du cycle limite acoustique atteint par les auto-oscillations générées dans un moteur thermoacoustique.Pour cela, un capteur d'impédance fort niveau est développé dans le but de mesurer l'impédance d'entrée d'un noyau thermoacoustique en fonction de la puissance de chauffage fournie, de la fréquence et de l'amplitude du forçage acoustique.L'utilisation de ces mesures permet de prédire avec succès la génération spontanée d'auto-oscillations ainsi que leur saturation jusqu'à un régime établi, pour différentes charges attachées au noyau.Les mesures ainsi obtenues sont comparées à un modèle établi sur la base de la théorie linéaire de la thermoacoustique, couplé un modèle thermique simplifié, menant à une meilleure compréhension des processus physiques responsables de la saturation des oscillations acoustiques.La procédure expérimentale décrite dans ce manuscrit permet aussi de proposer une méthode d'optimisation du couplage entre la charge et le noyau de manière à maximiser l'efficacité potentielle de la conversion d'énergie thermoacoustique.Finalement, une méthode expérimentale est décrite et permet l'étude de la stabilité des cycles limites, ou plus généralement de l'évolution lente de l'amplitude des auto-oscillations acoustiques, dans le cas où le moteur thermoacoustique est configuré de manière à donner lieu à un régime de déclenchements et arrêts périodiques. / This manuscript deals with the experimental characterization of the acoustic limit cycle reached by self-sustained oscillations generated in thermoacoustic engines.A specially designed, high amplitude, acoustic impedance sensor was developed to perform measurements of the input impedance of a thermoacoustic core, as a function of the heating power supplied to the device, of the frequency, and of the amplitude of acoustic forcing.Those measurements can then be used to predict the spontaneous generation of acoustic oscillations and their saturation up to a certain steady-state.Those predictions were successful for various acoustic loads connected to the thermoacoustic core.Moreover, the measurements of acoustic impedance as a function of the amplitude of acoustic oscillations are compared to a model based on the linear thermoacoustic theory, and this comparaison provides insights into the processes controlling the saturation of acoustic oscillations.The experimental procedure described in this manuscript also leads to a pratical way of optimizing the coupling between the thermoacoustic core and the load, in the way that the potential efficiency of thermoacoustic energy conversion is maximized.Finally, an experimental method is described and allows to study the stability of limit cycles, i.e. the temporal evolution of the self-oscillation amplitude, in the case of a system that is able to give rise to a spontaneous periodic \textit{trigg and stop} behavior.
3

Coil load changes for physiological motion acquisition in cardiac magnetic resonance imaging / Variations de charge d'antennes radio-fréquence pour la mesure de signaux physiologiques en imagerie cardiaque par résonance magnétique

Kudielka, Guido Peter 31 May 2016 (has links)
En imagerie par résonance magnétique cardiaque et thoracique, les mouvements cardiaques et respiratoires sont enregistrés avec des capteurs tels que les capteurs ECG et les ceintures respiratoires pour synchroniser les acquisitions et pour pratiquer des corrections rétrospectives des images. Le positionnement de ces capteurs augmente le temps de préparation des patients. Il présuppose également la tolérance des patients à être placés dans un espace restreint et déjà contraint par l'antenne radio-fréquence (RF) nécessaire à l'imagerie. Enfin, ces capteurs peuvent diminuer la qualité du signal et donc celle des images. Dans ces travaux, l'antenne RF déjà présente pour la réalisation de l'examen d'imagerie a été elle-même étudiée en tant que capteur de mouvements. Les variations des propriétés électromagnétiques des tissus dues aux mouvements se répercutent de manière directe sur l'impédance de l'antenne. Les variations d'impédance induites par les mouvements ont été étudiées dans des dispositifs utilisant soit des antennes RF volumiques ou des antennes RF surfaciques sur des objets-test animés et sur des sujets sains. Les mouvements respiratoires, cardiaques et les taux sanguins ont été enregistrés avec cette méthode. Puis, les résultats expérimentaux ont été comparés à des simulations électromagnétiques et aux données de la littérature. Une correction de mouvements rétrospective avec l'algorithme GRICS a été appliquée à ces données démontrant la faisabilité de l'utilisation des antennes d'imagerie comme capteurs de mouvements / Especially in cardiac and thoracic magnetic resonance imaging, respiratory motion and heart movement need to be registered using sensors like electrocardiogram or respiratory belts, in order to trigger the image acquisition or perform retrospective corrections. The placement of the sensors extends the patient preparation time, is critical for signal quality and, hence, image quality, and expects patients to tolerate additional sensors besides the imaging coil and space restrictions. In this work, the imaging coil itself was investigated for sensor-less motion registration. Motion-related variations of the electromagnetic properties of tissue have a direct effect on the coil impedance. Lung motion, myocardial-related motion, and vascular blood flow were registered with this method. The experimental findings were compared to electromagnetic simulations and the data gathered by state-of-the-art sensors, and retrospective motion correction with the GRICS algorithm was executed

Page generated in 0.0466 seconds