• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Métodos para implementação da dosimetria in vivo (dose de entrada) com dosímetros termoluminescentes na radioterapia externa com feixe de fótons

BARSANELLI, CRISTIANE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:43Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
2

Métodos para implementação da dosimetria in vivo (dose de entrada) com dosímetros termoluminescentes na radioterapia externa com feixe de fóton / Methods for implementation of in vivo dosimetry (entrance dose) using thermoluminescent dosimeters during radiotherapy treatment with photon beam

Barsanelli, Cristiane 23 November 2006 (has links)
Neste trabalho, estão descritos os métodos de seleção, calibração e de determinação dos fatores de correção, as características físicas dos dosímetros termoluminescentes, o procedimento de cálculo para converter a leitura do dosímetro em dose absorvida e a metodologia para se determinar a dose de entrada. Foram investigadas a praticidade e a utilidade das medidas de dose de entrada com os dosímetros termoluminescentes, bem como a exatidão e a reprodutibilidade no fornecimento da dose diária. As medidas de dose de entrada foram realizadas em cinco pacientes com diagnóstico de câncer de mama tratadas com um feixe de fótons de 6 MV. Não foram detectados grandes desvios entre a dose medida e a dose esperada (os valores concordaram em ± 5%), devido à excelente estabilidade do equipamento de tratamento, ao sistema automático de verificação e à boa exatidão no ajuste diário do tratamento. Uma boa precisão pode ser alcançada quando os fatores de correção para cada parâmetro de influência na resposta do dosímetro são cuidadosamente determinados e aplicados para converter o sinal termoluminescente em dose absorvida. O estudo demonstrou a viabilidade do uso dos dosímetros termoluminescentes para a dosimetria in vivo e sua utilidade como parte de um programa de garantia de qualidade em um serviço de radioterapia. / Selection, calibration procedure to convert TLD signal into absorbed dose and physical characteristics at the thermoluminescent dosimeters, as well as the determination of correction factors and the methodology to determine expected entrance dose, are described in this work. Practical aspects and the utility of entrance dose measures with thermoluminescent dosimeters were investigated, as well as the exactness and the reproducibility of the daily dose release. The entrance dose measures were performed in five patients with diagnosis of breast cancer treated with a 6 MV photon beam. The measured dose and the expected dose values agreed in ± 5%, due to excellent treatment equipment stability, to automatic verification system and the good exactness in the daily treatment adjustment. Good precision can be achieved when the correction factors for each parameter of influence in the dosimeter response are carefully determined and applied to convert the thermoluminescent signal into absorbed dose. The study demonstrates the viability of thermoluminescent dosimeters use for in vivo dosimetry and its utility as part of a quality assurance program in a radiation therapy service.
3

Métodos para implementação da dosimetria in vivo (dose de entrada) com dosímetros termoluminescentes na radioterapia externa com feixe de fóton / Methods for implementation of in vivo dosimetry (entrance dose) using thermoluminescent dosimeters during radiotherapy treatment with photon beam

Cristiane Barsanelli 23 November 2006 (has links)
Neste trabalho, estão descritos os métodos de seleção, calibração e de determinação dos fatores de correção, as características físicas dos dosímetros termoluminescentes, o procedimento de cálculo para converter a leitura do dosímetro em dose absorvida e a metodologia para se determinar a dose de entrada. Foram investigadas a praticidade e a utilidade das medidas de dose de entrada com os dosímetros termoluminescentes, bem como a exatidão e a reprodutibilidade no fornecimento da dose diária. As medidas de dose de entrada foram realizadas em cinco pacientes com diagnóstico de câncer de mama tratadas com um feixe de fótons de 6 MV. Não foram detectados grandes desvios entre a dose medida e a dose esperada (os valores concordaram em ± 5%), devido à excelente estabilidade do equipamento de tratamento, ao sistema automático de verificação e à boa exatidão no ajuste diário do tratamento. Uma boa precisão pode ser alcançada quando os fatores de correção para cada parâmetro de influência na resposta do dosímetro são cuidadosamente determinados e aplicados para converter o sinal termoluminescente em dose absorvida. O estudo demonstrou a viabilidade do uso dos dosímetros termoluminescentes para a dosimetria in vivo e sua utilidade como parte de um programa de garantia de qualidade em um serviço de radioterapia. / Selection, calibration procedure to convert TLD signal into absorbed dose and physical characteristics at the thermoluminescent dosimeters, as well as the determination of correction factors and the methodology to determine expected entrance dose, are described in this work. Practical aspects and the utility of entrance dose measures with thermoluminescent dosimeters were investigated, as well as the exactness and the reproducibility of the daily dose release. The entrance dose measures were performed in five patients with diagnosis of breast cancer treated with a 6 MV photon beam. The measured dose and the expected dose values agreed in ± 5%, due to excellent treatment equipment stability, to automatic verification system and the good exactness in the daily treatment adjustment. Good precision can be achieved when the correction factors for each parameter of influence in the dosimeter response are carefully determined and applied to convert the thermoluminescent signal into absorbed dose. The study demonstrates the viability of thermoluminescent dosimeters use for in vivo dosimetry and its utility as part of a quality assurance program in a radiation therapy service.

Page generated in 0.0729 seconds