Optofluidic Spectroscopy Platform for Detection of Hemolysis

Archibong, Edikan 20 November 2015 (has links)
In the United States alone, hundreds of millions of blood tests are performed annually, and a significant number of those tests are compromised due to hemolysis: e.g., 31% compromised in emergency rooms (inpatient) and 10% at blood banks, clinics, and other outpatient venues. Currently there is no way to reliably detect hemolysis without plasma separation. As a result, significant delays ensue, potentially negatively affecting patient diagnosis and treatment. In addition to in vitro hemolysis, which compromises the quality of blood tests, hemolysis can also occur in vivo. The in vivo occurrence of hemolysis is an indication of life-threatening complications. Being able to detect early signs of in vivo hemolysis would significantly improve outcomes for many patients, including pregnant women affected by HELLP (Hemolysis, Elevated Liver Enzymes, Low Platelet counts) syndrome. Therefore, there is a critical need to be able to detect hemolysis near the patient, immediately following the collecting of blood sample. The goal of this research is to provide an alternative to the traditional testing of blood samples, which requires large volumes of blood, centrifugation, and bulky instrumentation. The proposed alternative hemolysis detection system is a simple miniature setup that produces test results in minutes. This miniature, near-patient sensor would improve patients’ diagnosis, treatments, general satisfaction, and overall experience. The potential reduction of healthcare costs associated with hemolysis would be another significant benefit. The technology demonstrated in this dissertation is based on a novel combination of microfluidics, spectroscopy, and optical-fiber sensing. The microfluidics provide the capability to handle small volumes of liquid and to filter particles from solution. Novel membrane fabrication and modular integration provides the means to characterize and culture the captured particles. Spectroscopy and optical fibers provide the means to characterize the filtrate. These capabilities can be used for not only the detection of hemolysis but also other biomedical applications. . The first step in detecting hemolysis is to separate blood cells and other unwanted particulates from the plasma needed for optical analysis of concentration of hemoglobin. To that end, we focused initially on the problem of particle separation—specifically, within a microfabricated chamber with a custom-designed transparent membrane. To create a miniature microfluidic system capable of processing microliter blood samples, microelectromechanical systems (MEMS) fabrication techniques were required. The fabrication process included steps such as low-stress vapor deposition, photolithography, plasma, and wet etching. The resulting microdevice proved capable of filtering a variety of biological test fluids, including human lung fibroblast cancer cells from medium. The transparent membrane also allows for spectroscopic studies in broader applications, such as spectroscopic analysis or culturing of the cells retained on the filter. These capabilities were demonstrated using microbeads and cancer cells in solution. Optical techniques are used to analyze the separated blood plasma for concentration of hemoglobin. To integrate spectroscopic capabilities with the above microfluidics system, an optical fiber–based miniature probe was attached to the microfabricated chamber. As proof of concept, this system was tested in an application that required the measurement of physiologically relevant concentrations of cobalamin (vitamin B12). This application was used to address human error in drug administration showing measurements of cobalamin concentration as an example drug that can be monitored. The clinical means range of concentrations is from 1 µg/ml to 1000 µg/ml. The achieved results showed measurements of concentrations between 1 µg /mL to 5 mg/mL to monitor the physiological range and potential overdose in microliter of volume. This device has potential for numerous applications, ranging from single cell spectroscopy to measurements of glucose concentrations. This integrated system was then applied to the detection of hemolysis. The complete system conducts optofluidic spectroscopy with the optical fiber probe connected to the microfabricated chamber, which locally filters out blood cells, and reliably determine amount of free hemoglobin with the need for centrifuging. The utility of the device was demonstrated by its accurate measurement of hemoglobin concentrations in blood plasma. Finally, to apply the concept of the detection system to clinical condition with a reliable, and low-cost system, especially useful for developing countries, a smartphone-based technology, is proposed. This technology delivers ultra-fast results for the detection of early signs of HELLP syndrome and preeclampsia with the goal to decrease mortality and morbidity. The smartphone-based diagnostics is low cost, high speed of operation together with high accuracy. Detection of 1 mg/dL of free hemoglobin was achieved which is comparable to gold standard assay which are time consuming, difficult to operate and expensive. This technology, in summary, integrates microfluidics with microfiltration and spectroscopic technology to conveniently separate and characterize blood plasma. The device can also provide important information about other complex biological samples. These measurements require only very small sample volumes.

Page generated in 0.0781 seconds