Monitoração terapêutica das concentrações plásmaticas da digoxina em pacientes com insuficiência cardíaca / Therapeutical monitoring of digoxinemia in heart failure outpatientsBARROS, Isabel Cristina Medeiros 27 October 2008 (has links)
Made available in DSpace on 2014-07-29T15:29:05Z (GMT). No. of bitstreams: 1
dissertacao isabel cristina.pdf: 549593 bytes, checksum: ff591d0e143ca66263716f60188e9801 (MD5)
Previous issue date: 2008-10-27 / It was investigated the clinical, lab and plasma digoxin concentration profiles in 15 cardiac heart failure (CHF) outpatients of the Cardiac Heart Service of the Goias Federal University Clinical Hospital. It was aimed to know plasma digoxin concentration profile in 15 cardiac heart failure (CHF) outpatients by two analytical methods, taking account clinical, laboratorial, habits, anthropometric data and drug
usage. Digoxin dosage was developed by LC/MS/MS and immunoassay methods; questionnaire and consults handbooks were performed. Results and Conclusions: 87% of the patients who over 46 years of age (33% above 61), the masculine majority; the IC of Chagas disease origin presented greater
occurrence, followed of the hipertensive and idiopatic (59%); IC functional classroom II (53.33%); hypertension and diabetes had been distinguished as co-morbidities (26.67% and 20%); tobaccoism, overweight and obesity degree
I had presented low occurrence. No patients presented relevant clinical data suggestive of digitalis intoxication. No observed changes in biochemical and hematological exams. The ejection fractions were good by means 41.7 ± 9%.
Some drugs with interaction potential had been associated to the treatment, apparently without alterations. Statistical significative difference between both methods was observed (P < 0.05, ANOVA, Tukey Test). In the immunoassay
method, all the patients were inside of the therapeutical range (0, 5-2, 0 ng/mL), whereas for the LC-MS/MS method, 8 patients they would be in subtherapeutical concentrations. However, no patient presented signals or symptoms of poisoning or inefficacy of the digoxin, demonstrating biological
variability. The two methods are useful, since that it has a correlation with the clinical and laboratorial state of the patients. / Investigou-se o perfil clínico, laboratorial e as concentrações de digoxina plasmática em 15 pacientes com insuficiência cardíaca (IC) atendidos no Ambulatório de Insuficiência Cardíaca do HC-UFG. Objetivou-se estudar o perfil de concentrações plasmáticas de digoxina em pacientes com IC, utilizando dois métodos analíticos, e descrever a digoxinemia considerando os dados clínicos, laboratoriais, hábitos, IMC
e consumo de medicamentos. A metodologia utilizada consistiu de cromatografia líquida de alta eficiência acoplada a espectrometria de massas (LC/MS/MS) e Imunoensaio, aplicação de questionário e consulta a prontuários. Como resultados, observou-se: 87% dos pacientes maiores que 46 anos de idade (33% acima de 61), a maioria masculina, a IC de origem chagásica apresentou maior ocorrência, seguida da hipertensiva e idiopática (59%); IC classe funcional II (53,33%); hipertensão e diabetes destacaram-se como co-morbidades (26,67% e 20%); tabagismo, sobrepeso e obesidade grau I apresentaram baixa ocorrência. Nenhum
dos pacientes apresentou dados clínicos relevantes sugestivos de intoxicação digitálica. Não houve alterações em exames bioquímicos e hematológicos. A fração de ejeção média foi 41,7 ± 9%, portanto nenhum paciente apresentou FE como preditor de mau prognóstico. Vários fármacos com potencial de interação estiveram associados ao tratamento, aparentemente sem alterações. Houve diferença significativa (P < 0,05, ANOVA, Teste de Tukey) entre os métodos analíticos. No método de imunoensaio, todos os pacientes estavam dentro da faixa terapêutica (0,5-2,0 ng/mL), enquanto que pelo método LC-MS/MS, 8 pacientes estariam em sub-dosagens. Entretanto, nenhum paciente apresentou sinais ou sintomas de intoxicação ou de ineficácia da digoxina, demonstrando variabilidade biológica. Os dois métodos são úteis, desde que haja uma correlação com o estado clínico e
laboratorial dos pacientes.
|
2 |
Desenvolvimento e validação de metodologia por HPLC-PDA para monitoração terapêutica dos níveis plasmáticos de zidovudina e efavirenz / Development and validation of methodology for HPLC-PDA for therapeutic monitoring of plasma levels of zidovudine and efavirenzSOARES, Amanda Queiroz 01 October 2009 (has links)
Made available in DSpace on 2014-07-29T15:29:18Z (GMT). No. of bitstreams: 1
dissertacao amanda.pdf: 733204 bytes, checksum: a454e4fc6823529e279a29fcaea465c3 (MD5)
Previous issue date: 2009-10-01 / The therapeutic drug monitoring is an important tool to predict the
therapeutic efficacy and possible toxicity of antirretroviral agents used to treat
infection by human immunodeficiency virus (HIV). The goals of this study was to
develop and validate a method of analysis and extraction to quantify the
antirretrovirals efavirenz and zidovudine in human plasma, to know the clinical
profile and quantify the drugs efavirenz and zidovudine in plasma of volunteers
using treatment regimen efavirenz / lamivudine / zidovudine. Blood samples
were collected approximately 8 h after administration of AZT and 20 h of the
EFZ, were obtained from adult volunteers HIV positive in clinic monitoring at
Hospital das Clínicas, Universidade Federal de Goiás and therapeutic protocol
EFZ 600 mg once daily and lamivudine 150 mg + zidovudine 300 mg twice a
day. After solid phase extraction using cartridge Strata 18E C 500mg, 3 mL
capacity, the drugs and internal standard (5 - (4-methylphenyl)-5-fenilidantoína -
MPPH) were separated by reversed-phase column ACE 5 C18 100 x 4 6 mm.
The mobile phase consisted of acetonitrile and diethanolamine in water (pH 7.8),
flow rate 0.5 to 2.0 mL/min and detection at wavelength of 249 nm (EFZ), 267
nm (AZT) and 240 nm (MPPH). The method showed linearity at concentration
range of 50 to 5000 ng/mL for both drugs, with recovery of 84 and 92% for EFZ
and AZT, respectively. The limit of quantification (50 ng/mL), precision
(coefficient of variation <15%) and accuracy (relative errors <15%) are in
accordance with requirements of ANVISA. To evaluate the applicability of the
method, we analyzed plasma of volunteers (n = 12) with mean plasma
concentration of 1960 ± 766 ng/ mL to EFZ and 62.12 ± 16.21 ng/mL to AZT.
The method agree analytical parameters suitable for use in therapeutic
monitoring of patients using AZT and EFZ / A monitoração terapêutica de fármacos é uma importante ferramenta
para prever a eficácia terapêutica e a possível toxicidade dos agentes
antirretrovirais utilizados no tratamento da infecção pelo vírus da
imunodeficiência humana (HIV). Os objetivos deste estudo foram desenvolver e
validar uma técnica de análise e extração para quantificar os antirretrovirais
efavirenz e zidovudina no plasma humano, conhecer o perfil clínico e quantificar
os fármacos efavirenz e zidovudina no plasma dos sujeitos da pesquisa em uso
do esquema terapêutico efavirenz/lamivudina/zidovudina. Amostras de sangue,
coletadas aproximadamente 8 h após administração do AZT e 20 h do EFZ,
foram obtidas de sujeitos adultos com diagnóstico HIV positivo em
acompanhamento no Hospital das Clínicas da Universidade Federal de Goiás
com protocolo terapêutico EFZ 600 mg uma vez ao dia e lamivudina 150 mg +
zidovudina 300 mg duas vezes ao dia. Após extração em fase sólida utilizando
cartucho Strata C 18E 500mg, 3mL de capacidade, os fármacos e padrão
interno (5-(4-metilfenil)-5-fenilidantoína MPPH) foram separados em coluna
fase reversa ACE 5, C18 100 x 4,6 mm. A fase móvel utilizada foi composta por
acetonitrila e dietanolamina em água (pH 7,8), vazão de 0,5 a 2,0 mL/min e
detecção no comprimento de onda 249 nm (EFZ), 267 nm (AZT) e 240 nm
(MPPH). A técnica apresentou linearidade no intervalo de 50 a 5000 ng/mL para
ambos os compostos, com recuperação média de 84 e 92% para a AZT e EFZ,
respectivamente. O limite de quantificação (50 ng/mL), precisão (coeficiente de
variação < 15%) e exatidão (erros relativos < 15%) estão de acordo com
exigências da ANVISA. Para avaliar a aplicabilidade da técnica, analisou-se
amostras de plasma de sujeitos (n = 12), obtendo uma concentração plasmática
média de 1960 ± 766 ng/mL para EFZ e 62,12 ± 16,21 ng/mL para o AZT. A
técnica apresentou parâmetros analíticos adequados à sua utilização em
monitoração terapêutica de pacientes em uso de AZT e EFZ
|