• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 14
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Studies of the Performance Decay of a DMFC and the Development of a 16-cell DMFC Stack

Huang, Yu-wei 11 September 2009 (has links)
In this paper, a 16-cell direct methanol fuel cell (called DMFC) stack was developed to power or charge a mobile phone without any voltage transformer. The various types of the performance decay of DMFCs are studied before a 16-cell DMFC stack is made. The decays due to improper storage are found and avoided. The influences of the MEA treatments on the performance are also studied. Eventually, we try to find the best storage and treatment methods to keep stacks in a good condition all the way. In order to solve the problem of methanol crossover lead to the cathode poisoned, it is necessary to operate under the proper methanol concentration and to discharge before finishing the whole experiment. It is also necessary to maintain MEAs in proper wetness so that the performance will not decline during storage. Additionally, the catalyst in the cathode will use Pt/Ru to replace Pt. This 16-cell DMFC stack is composed of two 8-banded MEAs and 16 carbon fiber bunches. Each MEA is made with 8 sets of electrodes on a piece of membrane. The stack with 16 cells will be connected in series outside of the reaction chamber. The weight and volume of this 16-cell DMFC stack are 55 g (not including 20 c.c. methanol solution) and 99 cm3. The total electrode is 50 cm2 (16-cell¡Ñ3.15 cm2 per cell). The power at voltage 4V is 1680mW when it is operating at room temperature and air breathing. The maximum power density can reach 33 mW/cm2. The specific power density is 22 mW/g and the volumetric power density is 16.9 mW/cm3. This stack can power or charge a mobile phone directly.
2

Development and Fabrication Studies of Low Cost Air breathing Portable DMFC Stacks

Hung, Chia-lung 10 September 2007 (has links)
There are several disadvantages in conventional unipolar/bipolar plates such as cost expensive, weight heavy and volume large. Therefore, it is difficult in making use conventional unipolar/bipolar plates to portable fuel cells. With a new heterogeneous carbon fiber bipolar plate, pumpless and air-breathing design and in cooperating with a special MEA, portable fuel cell stacks developed in our lab have made portable applications to be possible. The structure of the DMFC stack made with the new carbon fiber bipolar plate is much more simple and weight-light than the other designs. A two-layer 16-Cell DMFC Stack had been designed and made by using the heterogeneous carbon fiber monopolar plates developed in our fuel cell laboratory. With this design, the methanol solution can be directly stored in the anode chamber which can store fuel 17 ml and does not need any auxiliary equipment, so it easy to apply to the portable power source. Not including fuel, total weight of stack is only 50g and the volume is 75 cm3. The 16 cell stack includes two pieces of 117 membrane, 16 anode electrodes loading Pt/Ru 5 mg/cm2 and 16 cathode Pt loading 5 mg/cm2. Each single cell electrode area is about 3.5 cm², so the total electrode area of the 16-cell stack is 56cm2. With methanol concentration 3 M, pumpless, air-breathing, and room temperature, the largest output power density of the fuel cell can reach 10.3 mW/cm², and the total power can reach 578 mW in this stage. The performance of the stack will be further improved in the next stage.
3

Evaluation of Cross-talk in Electromyographic Signals

Cena, Jacob Anthony January 2014 (has links)
Activity of skeletal muscles produce electrical signals that can be measured using electrodes placed on the skin surface over a target muscle or with electrodes inserted into the muscle. Such electromyographic (EMG) signals provide fundamental information about the intensity of the neural drive acting upon muscle. In addition, EMG signals are widely deployed as control sources for powered prosthetic limbs. One limitation related to recording EMG signals, however, is that signals arising from neighboring muscles may contribute significantly to the activity detected with electrodes placed over or within a given target muscle. Such unwanted contribution of signal from muscles other than the targeted muscle is referred to as cross-talk. Cross-talk was investigated in four neighboring muscles in the forearm with different electrode types and configurations: bipolar intramuscular, monopolar intramuscular, and bipolar surface EMG. Cross-correlation analysis was performed for every pairwise combination of EMG signal recorded. The peak correlation coefficient at near-zero time delay provided an index of the degree of cross-talk. Correlation coefficients dropped off exponentially with distance between recording electrodes. Bipolar intramuscular EMG had the narrowest pick-up range, with a length constant of 14.5 mm. Bipolar surface EMG had a longer length constant of 37.0 mm, whereas monopolar intramuscular EMG had the longest length constant of 64.5 mm. A second set of experiments indicated that correlation in EMG signals detected in different muscles was unlikely to have a neural basis. Therefore, because of their wide detection range, monopolar configurations including those involving intramuscular electrodes, should be avoided.
4

Characterization of distinct contrast- and luminance-sensitive pathways in the Drosophila visual system

Sporar, Katja 28 August 2019 (has links)
No description available.
5

Comparison of monopolar and bipolar diffusion weighted imaging sequences for detection of small hepatic metastases / 小肝転移の検出に対する単極性拡散強調画像と双極性拡散強調画像の比較

Furuta, Akihiro 23 January 2015 (has links)
京都大学 / 0048 / 新制・論文博士 / 博士(医学) / 乙第12889号 / 論医博第2089号 / 新制||医||1007(附属図書館) / 31643 / (主査)教授 福山 秀直, 教授 千葉 勉, 教授 平岡 眞寛 / 学位規則第4条第2項該当 / Doctor of Medical Science / Kyoto University / DFAM
6

Vibrações monopolares isoescalares em alguns núcleos duplamente mágicos / Isoscalar monopolar vibrations in some doubly magic nuclei.

Galetti, Diógenes 11 August 1978 (has links)
Usamos o formalismo de A. Toledo Pisa e E. Passos, que usa o método de coordenadas geradores e o Teorema Espectral de Anélise Funcional, para obter uma hamiltoniana coletiva para as vibrações monopolares isoescalares nos núcleos duplamente mágicos ANPOT. 4 He, ANPOT. 16 O e ANPOT 40 C. As funções de onda do oscilador hermônico são tomadas como funções de onda geradoras, e a interação de muitos corpos é aquela de Skyrme. Com esta hamiltoniana coletiva calculamos o espectro de energias do modo monopolar isoescalar, parâmetros de inércia e módulos de incompressibilidade para aqueles núcleos e comparamos com os resultados de Flocard e Vautherin, que resolvem numericamente a equação de Griffin-Wheeler. Foram calculados ainda os raios quadráticos médios nucleares. Os efeitos espúrios dos movimentos do centro de massa são eliminados exatamente para o AMPOT. 4 He e recalculamos aquelas propriedades nucleares. / The isoscalar monopole vibrational mode in 4 He,16 O and 40Ca is studied with the aid of collective Hamiltonians obtained from e general formalism proposed by A. Toledo Piza and E. Passos, which makes use of the generator coordinate method and Functional Analisis Spectral Theorem. Cur generator wave functions are that of the harmonic oscillator and use is made of the Skyrme\'s schematic effective interaction. Using the collective Hamiltonian we can calculate the energy spectrum, inertial parameters end incompressibility modulus and compare with numerical results of Flocard and Vautherin. R. m. s. radii are also calculated. Center of mass spurious effects are exactly eliminated and the forementioned nuclear properties are calculated again for 4 He.
7

Design and Development of a Long-term Operating and Without Performance Decay Passive Portable DMFC Stack

Yu, Ching-Hsiang 05 September 2011 (has links)
In this thesis, a long-term operation direct methanol fuel cell (DMFC) stack is developed. In order to reach this goal required in many ways, including select highly chemical stability materials, operating conditions must also be stable, and avoid changing the MEA structure when preserved, then can cause the DMFC to maintain stable operation for a long time. First of all, in order to avoid contaminating electrode, this study find out the chemical instability materials. Second, this study design a device which does not require power then can stability supply consumption fuel, and apply this device in 16-cell DMFC. Finally compare with continuous fuel supply and without fuel supply, two operating conditions performance stability. From these experiments can find out, the DMFC indeed in stable operation for a long time under the appropriate supplement. Traditional fuel supply systems typically using the pump fuel recycling, so the structure is more complex, difficult to reduce the volume, and not conducive to carry. If using a passive operation, fuel completely stored in the reaction Chamber, even though the structure is simple there will be a problem with fuel supply. In recent years, someone use vapors of methanol to supply the fuel, although can use high concentration methanol to extend operating time, but the evaporation rate is difficult to control, the fuel can¡¦t be supplied in time, especially when the large current is needed, and CROSSOVER issues would be difficult to overcome. In our 16-cell DMFC, continues to add appropriate amount of fuel consumed which according to the different current. The fuel supply device with a sliding control plate which can control methanol and water diffusion rate respectively. This device only to provide consumed by reaction and leaked fuel in anode chamber, so that the methanol concentration can maintained in the proper range at anode chamber. This device only use diffusion and gravity effects, don't use a fuel pump, so will not consume DMFC power.
8

Design and Development of a Stable Operating Passive Portable DMFC Stack

Tung, Tai-Hao 28 August 2012 (has links)
Abstract A one-watt portable air-breathing direct methanol fuel cell stack (called DMFC), which can supply fuel passively and operate steadily, is developed in this thesis. A DMFC to maintain its performance stable, the most important strategy is to keep the methanol concentration in reacting chamber to be proper and stable. A fuel supplying system will be in accordance with the depletion of chemical reaction and the leakage of fuel under different circuit current to supplying fuel. To regulate the methanol and water supplying, a fuel supplying system by gravitation and diffusion forces deliver methanol and water to fill up the consumed fuel to maintain the concentration of methanol solution in anode reaction chamber, by adjusting a sliding gate to control the area of a diffusive membrane and utilizing three cotton threads and hoses to distribute the fuel to proper location. In doing so, the methanol concentration in the anode chamber can keep within an appropriate range, so that the DMFC stack can operate stably for a longer period. Yet the diffusivity of the diffusive membrane is comparatively less, the supply system is not easy to downsize. To reduce the size of portable DMFC, we make use of a fuel plug tank to combine the supply tank and reacting chamber, and thus the cell package is more portable. Between the plug tank and the reacting chamber, the three cotton threads are used to distribute the fuel to proper location. The above two design with no extra auxiliary device; therefore, no extra energy will be consumed. To reduce the fuel leakage, and make more use of fuel, four block films is pasted on the bare area of the nafion membranes in a 16-cell DMFC stack. If no fuel is fed into reaction chamber, this will prolong the cell operation time. Under the condition of 3.7 V (cell phone rated voltage) and the operating current 225 mA, our experiments display that the stacks with the two fuel supplying systems can continuously operate for more than 3 hours with no obvious change in methanol concentration within reaction chamber. The experimental results show that this simple passive fuel supplemental system can really keep the DMFC stack operating stably for a sufficient long period.
9

Vibrações monopolares isoescalares em alguns núcleos duplamente mágicos / Isoscalar monopolar vibrations in some doubly magic nuclei.

Diógenes Galetti 11 August 1978 (has links)
Usamos o formalismo de A. Toledo Pisa e E. Passos, que usa o método de coordenadas geradores e o Teorema Espectral de Anélise Funcional, para obter uma hamiltoniana coletiva para as vibrações monopolares isoescalares nos núcleos duplamente mágicos ANPOT. 4 He, ANPOT. 16 O e ANPOT 40 C. As funções de onda do oscilador hermônico são tomadas como funções de onda geradoras, e a interação de muitos corpos é aquela de Skyrme. Com esta hamiltoniana coletiva calculamos o espectro de energias do modo monopolar isoescalar, parâmetros de inércia e módulos de incompressibilidade para aqueles núcleos e comparamos com os resultados de Flocard e Vautherin, que resolvem numericamente a equação de Griffin-Wheeler. Foram calculados ainda os raios quadráticos médios nucleares. Os efeitos espúrios dos movimentos do centro de massa são eliminados exatamente para o AMPOT. 4 He e recalculamos aquelas propriedades nucleares. / The isoscalar monopole vibrational mode in 4 He,16 O and 40Ca is studied with the aid of collective Hamiltonians obtained from e general formalism proposed by A. Toledo Piza and E. Passos, which makes use of the generator coordinate method and Functional Analisis Spectral Theorem. Cur generator wave functions are that of the harmonic oscillator and use is made of the Skyrme\'s schematic effective interaction. Using the collective Hamiltonian we can calculate the energy spectrum, inertial parameters end incompressibility modulus and compare with numerical results of Flocard and Vautherin. R. m. s. radii are also calculated. Center of mass spurious effects are exactly eliminated and the forementioned nuclear properties are calculated again for 4 He.
10

Novel Performance Evaluation Method for Electrosurgical Ablation by Monopolar Hot Biopsy Forceps

Tang, Chen 22 July 2016 (has links)
No description available.

Page generated in 0.038 seconds