Spelling suggestions: "subject:"monotonic anda cyclic loading"" "subject:"monotonic ando cyclic loading""
1 |
The Racking Performance of Light-Frame Shear WallsSalenikovich, Alexander J. 26 September 2000 (has links)
The response of light-frame timber shear walls to lateral forces is the focus of the dissertation. The objective of this study was to obtain performance characteristics of shear walls with various aspect ratios and overturning restraint via experimental testing and analytical modeling. Presented are the test data of monotonic and cyclic tests on fifty-six light-frame timber shear walls with aspect ratios of 4:1, 2:1, 1:1, and 2:3. Overturning restraint conditions represent engineered construction and conventional construction practices. The walls representative of the engineered construction were attached to the base by means of tie-down anchors and shear bolts. As opposed to engineered construction, conventionally built walls were secured to the base by nails or shear bolts only. The specimens were tested in a horizontal position with oriented strandboard (OSB) sheathing on one side. To obtain conservative estimates, no dead load was applied in the wall plane during the tests. The nail-edge distance across the top and bottom plates varied from 10 mm (3/8 in.) to 19 mm (3/4 in.). Twelve walls were repaired after the initial tests and re-tested. A mechanics-based model was advanced to predict the racking resistance of conventional multi-panel shear walls using simple formulae. The deflections of engineered and conventional shear walls were predicted using the energy method combined with empirical formulae to account for load-deformation characteristics of sheathing-to-framing connections and overturning restraint. The proposed formulae were validated through comparison with test results obtained during this study. The results of the study serve to further development of a mechanics-based methodology for design of shear walls accounting for various wall configurations and boundary conditions. / Ph. D.
|
2 |
Monotonic and Cyclic Performance of Light-Frame Shear Walls with Various Sheathing MaterialsToothman, Adam James 28 January 2003 (has links)
The racking performance of light-frame shear walls subjected to monotonic and cyclic loading is the focus of this thesis. The sheathing materials investigated are oriented strandboard (OSB), hardboard, fiberboard, and gypsum wallboard. The objectives of this study were to (1) obtain and compare performance characteristics of each sheathing material; (2) compare the effects of monotonic loading versus the cyclic loading response; (3) investigate the contribution of gypsum in walls with dissimilar sheathing materials on opposite sides of the wall; and (4) study the effects of using overturning anchors. The monotonic tests, which incorporated the use of hold-downs, were performed according to ASTM E564. Half of the cyclic tests were performed with hold-downs, and half were performed without hold-downs. The cyclic tests were performed according to the recently adopted cyclic testing procedure ASTM E2126.
A total of forty-five walls were tested with various configurations. The size of the walls was 1.2 x 2.4m (4 x 8ft). Two tests were performed with each sheathing material subjected to each type of loading: monotonic, cyclic with hold-downs, and cyclic without hold-downs. Two tests were then performed with OSB, hardboard, or fiberboard on one side of the wall and gypsum on the other side of the wall to study the effects of using dissimilar sheathing materials on the shear walls. The OSB and hardboard exhibited similar performance, and were the strongest of the four sheathing materials. Fiberboard performed better than gypsum, but worse than OSB and hardboard. In general, the performance indicators decreased when the walls were subjected to cyclic loading. The contribution of gypsum to walls with hold-downs was significant, but was not linearly additive. The use of hold-downs had a large effect on the performance of the walls. All shear wall performance indicators decreased when hold-downs were not included, with an average reduction of 66% in the peak load. / Master of Science
|
3 |
Experimental and numerical studies of masonry wall panels and timber frames of low-rise structures under seismic loadings in IndonesiaSusila, Gede Adi January 2014 (has links)
Indonesia is a developing country that suffers from earthquakes and windstorms and where at least 60% of houses are non-engineered structures, built by unskilled workers using masonry and timber. The non-engineered housing units developed in urban region are also vulnerable to seismic hazard due to the use of low quality of material and constructions method. Those structures are not resistant to extreme lateral loads or ground movement and their failure during an earthquake or storm can lead to significant loss of life. This thesis is concerned with the structural performance of Indonesian low-rise buildings made of masonry and timber under lateral seismic load. The research presented includes a survey of forms of building structure and experimental, analytical and numerical work to predict the behaviour of masonry wall and traditional timber frame buildings. Experimental testing of both masonry and timber have been carried out in Indonesia to establish the quality of materials and to provide material properties for numerical simulations. The experimental study found that the strength of Indonesia-Bali clay brick masonry are below the minimum standard required for masonry structures built in seismic regions, being at least 50% lower than the requirement specified in British Standard and Eurocode-6 (BS EN 1996-1-1:2005). In contrast, Indonesian timber materials meet the strength classes specified in British Standard/Eurocode- 5 (BS EN 338:2009) in the range of strength grade D35-40 and C35).Structural tests under monotonic and cyclic loading have been conducted on building components in Indonesia, to determine the load-displacement capacity of local hand-made masonry wall panels and timber frames in order to: (1) evaluate the performance of masonry and timber frame structure, (2) investigate the dynamic behaviour of both structures, (3) observe the effect of in-plane stiffness and ductility level, and (4) examine the anchoring joint at the base of timber frame that resists the overturning moment. From these tests, the structural ductility was found to be less than two which is below the requirement of the relevant guidelines from the Federal Emergency Management Agency, USA (FEMA-306). It was also observed that the lateral stiffness of masonry wall is much higher than the equivalent timber frame of the same height and length. The experimental value of stiffness of the masonry wall panel was found to be one-twelfth of the recommended values given in FEMA-356 and the Canadian Building code. The masonry wall provides relatively low displacement compared to the large displacement of the timber frame at the full capacity level of lateral load, with structural framing members of the latter remaining intact. The weak point of the timber frame is the mechanical joint and the capacity of slip joint governs the lateral load capacity of the whole frame. Detailed numerical models of the experimental specimens were setup in Abaqus using three-dimensional solid elements. Cohesive elements were used to simulate the mortar behaviour, exhibiting cracking and the associated physical separation of the elements. Appropriate contact definitions were used where relevant, especially for the timber frame joints. A range of available material plasticity models were reviewed: Drucker-Prager, Crystalline Plasticity, and Cohesive Damage model. It was found that the combination of Crystalline Plasticity model for the brick unit and timber, and the Cohesive Damage model for the mortar is capable of simulating the experimental load-displacement behaviour fairly accurately. The validated numerical models have been used to (1) predict the lateral load capacity, (2) determine the cracking load and patterns, (3) carry out a detailed parametric study by changing the geometric and material properties different to the experimental specimens. The numerical models were used to assess different strengthening measures such as using bamboo as reinforcement in the masonry walls for a complete single storey, and a two-storey houses including openings for doors and windows. The traditional footing of the timber structures was analysed using Abaqus and was found to be an excellent base isolation system which partly explains the survival of those structures in the past earthquakes. The experimental and numerical results have finally been used to develop a design guideline for new construction as well as recommendations for retrofitting of existing structures for improved performance under seismic lateral load.
|