Avaliação do comportamento de isoladores de média tensão frente a sobretensões atmosféricas bipolares / Evaluation of the behavior of medium insulators voltage to bidirectionally atmospheric overvoltage

Silva, Alexandre Rigotti 16 August 2018 (has links)
As linhas de distribuição de energia estão frequentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2/ 50 µs). Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Este trabalho visa avaliar o comportamento de isoladores de média tensão quando sujeitos a sobretensões atmosféricas bipolares oscilatórias. Simulações realizadas usando o \"Extended Rusck Model\"(ERM) e resultados de medições demonstram que a ocorrência de sobretensões bipolares oscilatórias em linhas de distribuição não é um fato raro, pois descargas atmosféricas podem, sob certas condições, induzir tensões com tais características. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões bipolares de três períodos distintos: 2,2 µs, 4,1 µs e 6,0 µs. Este trabalho investiga o comportamento de um típico isolador de porcelana tipo pino de 15 kV sujeito a um impulso bipolar, representativo de uma tensão induzida por um raio. Mostra-se que uma modificação no método proposto por Savadamuthu et al. para estimar a suportabilidade do isolamento de pequenos (alguns milímetros) sistemas de isolamento submetidos a tensões oscilantes bipolares leva a resultados promissores em termos de previsão da ocorrência de descargas no isolador de classe 15 kV. / Power lines are often exposed to surges caused by direct and indirect lightning. The waveforms of these overvoltages may differ significantly from the standard lightning impulse used in tests to verify the adequacy of equipment insulation designs against atmospheric overvoltages (1.2/50 µs). Different models have been proposed to estimate the performance of the insulation against non-normalized impulses, with the disruptive effect model being one of the most used. This work aims at evaluating the behavior of medium voltage insulators when subjected to bidirectionally oscillating voltages. Simulations run using the Extended Rusck Model (ERM) and measurement results show that the occurrence of bipolar oscillating overvoltages are not rare on power distribution lines, as lightning strokes can induce, under certain conditions, voltages with such characteristics. Modifications performed in the circuit of a conventional high voltage pulse generator allowed the generation of bipolar voltages of three distinct periods: 2.2 µs, 4.1 µs and 6.0 µs. This work investigates the behavior of a typical 15 kV pin-type porcelain insulator subjected to bipolar impulses representative of lightning-induced voltages. It is shown that a modification on the method proposed by Savadamuthu et al. to estimate the insulation strength of small (a few mm) insulation systems subjected to bipolar oscillating voltages leads to promising results in terms of predicting the occurrence of flashovers on the 15 kV insulator.
2

Avaliação do comportamento dielétrico de isoladores de distribuição de média tensão frente a impulsos atmosféricos com formas de onda não normalizadas / Analysis of the dielectric behavior of medium voltage insulators under non-standard lightning impulse voltages

Braz, Celso Pereira 18 April 2011 (has links)
As linhas de distribuição de energia estão freqüentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões têm uma faixa de variação muito ampla e podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2 / 50 microssegundos). É fato conhecido que a suportabilidade das isolações depende não só da amplitude como da forma de onda das solicitações. Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Existem, contudo, diferentes métodos de aplicação desse modelo, ou seja, diferentes formas de se estimar os parâmetros necessários para a sua aplicação. Este trabalho visa avaliar o comportamento dielétrico de isoladores de média tensão e analisar os principais métodos para estimativa da suportabilidade desses equipamentos frente a sobretensões atmosféricas com formas de onda diferentes da normalizada. Para essa avaliação foram realizados ensaios em um isolador tipo pino, de porcelana, com tensão nominal de 15 kV, nos quais foram utilizadas, além do impulso atmosférico normalizado, outras ondas selecionadas com base em resultados de medição e de cálculo. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões com formas de onda bastante semelhantes às de sobretensões induzidas por descargas atmosféricas tanto em linhas de tamanho natural como em experimentos realizados com modelo reduzido. São apresentados e discutidos os resultados dos ensaios de tensão disruptiva de impulso atmosférico a 50 % e as curvas tensão-tempo (U x t) obtidas para cada impulso, considerando ambas as polaridades. A avaliação dos métodos de aplicação do modelo do efeito disruptivo foi realizada com base em comparações entre as curvas tensão-tempo obtidas nos ensaios e as curvas previstas por cada modelo, para cada uma das ondas selecionadas. / Overhead distribution lines are often exposed to lightning overvoltages, whose waveshapes vary widely and can differ substantially from the standard impulse voltage waveshape used to test electric equipment insulation against lightning surges (1.2 / 50 microseconds wave). It is well known that the voltage withstand capability of insulation depends not only on the amplitude but also on the voltage waveshape. Different models have been proposed for predicting the strength of insulation subjected to impulses of non-standard waveshapes. One of the most commonly used is the \"disruptive effect model\". There are, however, different methods of applying this model, that is, different ways of estimating the parameters needed for its application. This thesis aims at evaluating the dielectric behavior of medium voltage insulators subjected to impulses of non-standard waveshapes, as well as at evaluating the main methods for predicting their dielectric strength against such impulses. For the analysis, tests were performed on a pin type porcelain insulator with rated voltage of 15 kV, using, besides the standard lightning impulse voltage waveshape, other s waveshapes selected based on the characteristics of measured and calculated lightning overvoltages. Modifications made to the circuit of a conventional impulse voltage generator allowed to obtain voltage waveshapes very similar to those of lightning-induced voltages measured in experiments conducted both in lines of natural size and in reduced model. The test results relative to the critical lightning impulse flashover voltage (U50) and the volt-time characteristics obtained for the positive and negative polarities of each waveshape are presented and discussed. The evaluation of the methods of determining the parameters of the disruptive effect model was based on comparisons between the volt-time curves obtained from the laboratory tests and those predicted by each method, for each of the selected voltage waveshapes.
3

Avaliação do comportamento dielétrico de isoladores de distribuição de média tensão frente a impulsos atmosféricos com formas de onda não normalizadas / Analysis of the dielectric behavior of medium voltage insulators under non-standard lightning impulse voltages

Celso Pereira Braz 18 April 2011 (has links)
As linhas de distribuição de energia estão freqüentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões têm uma faixa de variação muito ampla e podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2 / 50 microssegundos). É fato conhecido que a suportabilidade das isolações depende não só da amplitude como da forma de onda das solicitações. Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Existem, contudo, diferentes métodos de aplicação desse modelo, ou seja, diferentes formas de se estimar os parâmetros necessários para a sua aplicação. Este trabalho visa avaliar o comportamento dielétrico de isoladores de média tensão e analisar os principais métodos para estimativa da suportabilidade desses equipamentos frente a sobretensões atmosféricas com formas de onda diferentes da normalizada. Para essa avaliação foram realizados ensaios em um isolador tipo pino, de porcelana, com tensão nominal de 15 kV, nos quais foram utilizadas, além do impulso atmosférico normalizado, outras ondas selecionadas com base em resultados de medição e de cálculo. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões com formas de onda bastante semelhantes às de sobretensões induzidas por descargas atmosféricas tanto em linhas de tamanho natural como em experimentos realizados com modelo reduzido. São apresentados e discutidos os resultados dos ensaios de tensão disruptiva de impulso atmosférico a 50 % e as curvas tensão-tempo (U x t) obtidas para cada impulso, considerando ambas as polaridades. A avaliação dos métodos de aplicação do modelo do efeito disruptivo foi realizada com base em comparações entre as curvas tensão-tempo obtidas nos ensaios e as curvas previstas por cada modelo, para cada uma das ondas selecionadas. / Overhead distribution lines are often exposed to lightning overvoltages, whose waveshapes vary widely and can differ substantially from the standard impulse voltage waveshape used to test electric equipment insulation against lightning surges (1.2 / 50 microseconds wave). It is well known that the voltage withstand capability of insulation depends not only on the amplitude but also on the voltage waveshape. Different models have been proposed for predicting the strength of insulation subjected to impulses of non-standard waveshapes. One of the most commonly used is the \"disruptive effect model\". There are, however, different methods of applying this model, that is, different ways of estimating the parameters needed for its application. This thesis aims at evaluating the dielectric behavior of medium voltage insulators subjected to impulses of non-standard waveshapes, as well as at evaluating the main methods for predicting their dielectric strength against such impulses. For the analysis, tests were performed on a pin type porcelain insulator with rated voltage of 15 kV, using, besides the standard lightning impulse voltage waveshape, other s waveshapes selected based on the characteristics of measured and calculated lightning overvoltages. Modifications made to the circuit of a conventional impulse voltage generator allowed to obtain voltage waveshapes very similar to those of lightning-induced voltages measured in experiments conducted both in lines of natural size and in reduced model. The test results relative to the critical lightning impulse flashover voltage (U50) and the volt-time characteristics obtained for the positive and negative polarities of each waveshape are presented and discussed. The evaluation of the methods of determining the parameters of the disruptive effect model was based on comparisons between the volt-time curves obtained from the laboratory tests and those predicted by each method, for each of the selected voltage waveshapes.