• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

CONE BEAM OPTICAL COMPUTED TOMOGRAPHY-BASED GEL DOSIMETRY

OLDING, TIMOTHY 02 September 2010 (has links)
The complex dose distributions delivered by modern, conformal radiation therapy techniques present a considerable challenge in dose verification. Traditional measurement tools are difficult and laborious to use, since complete verification requires that the doses be determined in three dimensions (3D). The difficulty is further complicated by a required target accuracy of ± 5% for the dose delivery. Gel dosimetry is an attractive option for realizing a tissue-equivalent, 3D dose verification tool with high resolution readout capabilities. However, much important work remains to be completed prior to its acceptance in the clinic. The careful development of easily accessible, fast optical readout tools such as cone beam optical computed tomography (CT) in combination with stable and reliable low-toxicity gel dosimeters is one key step in this process. In this thesis, the performance capabilities and limitations of the two main classes of cone beam optical CT-based absorbing and scattering gel dosimetry are characterized, and their measurement improved through careful matching of dosimeter and scanner performance. These systems are then applied to the evaluation of clinically relevant complex dose distributions. Three-dimensional quality assurance assessments of complex treatment plan dose distributions are shown to be feasible using an optically absorbing Fricke-xylenol-orange-gelatin-based gel dosimeter. Better than 95% voxel agreement is achieved between the plan and the delivery, using 3% dose difference and 3 mm spatial distance-to-agreement gamma function comparison criteria. Small field dose delivery evaluations are demonstrated to be viable using an optically scattering N-isopropylacrylamide (NIPAM)-based polymer gel, with the same comparison criteria. Full treatment process quality assurance is also possible using a NIPAM dosimeter in-phantom, but is limited in its accuracy due to the inherent difficulty of managing the effects of stray light pertubation in the optical attenuation-to-dose calibration. / Thesis (Ph.D, Physics, Engineering Physics and Astronomy) -- Queen's University, 2010-09-02 15:01:48.501

Page generated in 0.092 seconds