• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design and Verification of an Optical System to Interrogate Dermally-implanted Microparticle Sensors

Long, Ruiqi 2012 May 1900 (has links)
Diabetes mellitus affects 25.8 million Americans (8.3%) and over 300 million people worldwide. Clinical trials indicate that proper management of blood glucose levels is critical in preventing or delaying complications associated with diabetes. Thus, there is a common need to monitor and manage blood glucose properly for people with diabetes. However, the patients’ compliance for recommended monitoring frequency is low due to the pain and inconvenience of current standard finger-pricking tests. To promote patient adherence to the recommended self-monitoring frequency, non-invasive/ minimally invasive glucose testing approaches are needed. Luminescent microparticle sensor is an attractive solution. For these sensors to be deployed in vivo, a matched optical system is needed to interrogate dermally-implanted sensors. This research project investigated the light propagation in skin and the interaction with implants using Monte Carlo modeling. The results of the modeling were used to design an optical system with high interrogation and collection efficiency (40~300 times improvement). The optical system was then constructed and evaluated experimentally. A stable skin phantom mimicking the optical properties of human skin was developed as a permanent evaluation medium to minimize the use of animals. The optical properties of the skin phantom matched the maximum published values of human skin in scattering and absorption over the spectral range of 540~700nm in order to avoid overestimation of the capability of the system. The significant photon loss observed at the connection between the designed system and a commercial spectrometer was overcome using two optimized designs: a two-detector system and a customized low-resolution spectrometer system. Both optimization approaches effectively address the photon loss problem and each showed good SNR (>100) while maintaining a sufficient system resolution for use with fluorescent materials. Both systems are suitable for luminescence measurement, because broad bands of the luminescent spectrum are of interest. In the future, either system can be easily modified into a more compact system (e.g. handheld), and it can be directly coupled to an analog-to-digital converter and integrated circuits offering potential for a single compact and portable device for field use with luminescent diagnostic systems as well as implanted sensors.
2

Model-based analysis of fiber-optic extended-wavelength diffuse reflectance spectroscopy for nerve detection

Sun, Yu, 0000-0003-0048-8352 January 2022 (has links)
Optical spectroscopy is a real-time technique that holds promise as a potential surgical guidance tool. Fiber-optic diffuse reflectance spectroscopy (DRS) is a technique capable of intraoperative tissue differentiation. The common DRS focuses on estimating chromophore concentrations in the visible (VIS) wavelength range (400-1000 nm), where spectroscopic features of the blood, pigments, and tissue densities are present between 400 and 700 nm. Recently, extended-wavelength DRS (EWDRS), which extends the spectral window from the VIS through the short wave-infrared region (SWIR) up to 1800 nm, has emerged as a promising approach for identifying nerves and nerve bundles due to the SWIR including robust tissue absorption features associated with nerve-tissue related chromophores, including lipids, water and collagen proteins. One potential application of EWDRS is guiding minimally invasive surgical techniques, such as laparoscopy, where inadvertent injury to pelvic autonomic nerves (PANs) is a primary complication that can result in over 70% of patients suffering long-term side effects, including urinary incontinence and sexual dysfunction. There is a need for objective laparoscopic surgical guidance to precisely identify PANs from other tissues, and an improved basis for EWDRS development could assist clinical translation. Prior development of Fiber-optic DRS for tissue classification in the VIS greatly benefited from the application of modeling techniques for simulation of optical measurements, analysis, and fiber-probe design. Model-based analysis can inform fundamental understanding of measured signals in different measurement scenarios, such as the varying tissue morphologies possible in laparoscopic procedures, and guide application-specific fiber-probe design through comparison of unique illumination/collection geometries; however, the demonstration of these approaches in EWDRS is not widely reported. This dissertation focuses on the advancement of platforms for model-driven analysis of EWDRS for nerve identification. In order to advance the current state of EWDRS, a model-based characterization platform for analysis of a custom-developed fiber-optic EWDRS system was developed in Aim 1, which demonstrated agreement between data collected from optical phantoms, ex vivo microsurgical model, and Monte Carlo (MC) computational simulations of EWDRS measurements. In Aim 2, the model-based platform was used to perform a detailed analysis of two similar EWDRS fiber-optic probes, which indicated subtle differences in the depth-dependent measurement performance. Finally, in Aim 3, the custom EWDRS was prepared for adapting laparoscopic use to demonstrate laparoscopic measurement feasibility, including evaluation of placement variance and customized EWDRS package for short-distance transportation. The successful completion of this dissertation will enable improved analyses of EWDRS devices for a variety of future intraoperative applications. / Bioengineering

Page generated in 0.0739 seconds