• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uma avaliaÃÃo de viabilidade financeira no uso da energia solar fotovoltaica apoiada pela resoluÃÃo ANEEL 482/2012 sobre geraÃÃo distribuÃda no setor elÃtrico do Brasil. / An assessment of financial viability in the use of photovoltaic solar energy supported by ANEEL Resolution 482/2012 on distributed generation in the electricity sector in Brazil.

Francisco Ivanhoel Aguiar de Carvalho 03 July 2014 (has links)
nÃo hà / A presente dissertaÃÃo analisa a viabilidade financeira de implantaÃÃo de projetos de geraÃÃo de energia fotovoltaica na perspectiva do consumidor. AtravÃs da ResoluÃÃo Normativa ANEEL 482/2012, que estabelece as condiÃÃes gerais para o acesso de microgeraÃÃo e minigeraÃÃo conferidas aos sistemas de distribuiÃÃo de energia elÃtrica por meio do mÃtodo de compensaÃÃo do referido produto energÃtico. Para tanto, a pesquisa foi realizada sobre os Sistemas Fotovoltaicos Conectados à Rede â SFCR, atravÃs da construÃÃo de dois cenÃrios: (i) proposta de auto-suficiÃncia em geraÃÃo fotovoltaica, pagando o custo de disponibilidade da distribuidora e os impostos devidos e (ii) onde o intuito à utilizar a energia fotovoltaica de forma a anular o âhorÃrio de solâ na geraÃÃo alternativa, tambÃm arcando com custos de disponibilidade e impostos devidos. As simulaÃÃes utilizaram o painel KD140SX-UPU, por seu custo benefÃcio e vida Ãtil, tomando por base a tarifa do consumidor residencial B1 homologada pela ANEEL para a COELCE atravÃs da ResoluÃÃo HomologatÃria 1.711/2014, que à de 0,35922 R$/kWh. O resultado da anÃlise econÃmica para o consumidor mostrou-se atrativa apenas no cenÃrio (ii) uma vez que a Taxa Interna de Retorno foi maior que a Taxa MÃnima de Atratividade e o tempo mÃdio de Payback calculado de 9,92 anos. Acerca de efeitos para a concessionÃria de energia, as discussÃes indicaram que a adesÃo de potenciais consumidores, provavelmente da ultima faixa de consumo (maior que 220 kWh) poderia ocasionar impactos econÃmicos na Receita Operacional Liquida, o que pode ser objeto de pesquisas futuras, mas que a rede elÃtrica seria afetada de forma positiva, uma vez que a carga descentralizada traria uma reduÃÃo de perdas, estabilidade de tensÃo de fornecimento e a possibilidade de postergaÃÃo dos investimentos na ampliaÃÃo da rede de distribuiÃÃo. A pesquisa conclui que a implementaÃÃo plena da ResoluÃÃo ANEEL 482/2012 torna-se viÃvel com modificaÃÃes regulatÃrias, regras claras no aspecto tÃcnico, maior participaÃÃo governamental na concessÃo de incentivos financeiros e em linhas especiais de financiamento. Por estas implementaÃÃes, benefÃcios tarifÃrios poderiam refletir de forma positiva para o consumidor cativo, uma vez a energia excedente injetada na rede, acarretaria um melhor planejamento de engenharia das empresas, dimensionando melhor os equipamentos elÃtricos, otimizando, assim, os Ãndices de aproveitamento destes bens, aumentando sua vida Ãtil e contribuindo para a modicidade tarifÃria. / This dissertation analyzes the financial viability deployment of photovoltaic power generation projects from a consumer perspective. By ANEEL Normative Resolution 482/2012, which establishes the general conditions for micro-generation access and minigeneration granted to electricity distribution systems via the compensation method of that energy product. Therefore, the survey was conducted on Photovoltaic Systems Connected to Network - SFCR through the construction of two scenarios: (i) proposal for self-sufficiency in photovoltaic generation, paying the cost of distribution and availability taxes due and (ii ) where the aim is to use photovoltaics in order to cancel the "sun hours" in alternative generation, also bearing availability and costs owed taxes. The simulations used the KD140SX-UPU panel for his money and life, based on the residential user tariff B1 approved by ANEEL for COELCE through Ratifying Resolution 1,711 / 2014, which is US $ 0.35922 / kWh . The outcome of the economic analysis for the consumer proved to be attractive only in the scenario (ii) since the internal rate of return was higher than the Minimum Rate of Attractiveness and the average time calculated Payback 9.92 years. About effects on power utility, the discussions indicated that the accession of potential consumers, probably the last track consumption (greater than 220 kWh) could cause economic impacts in Net Operating Revenue, which can be further research object, but that the grid would be affected in a positive way, since the decentralized load would bring a reduction of losses, supply voltage stability and the possibility of postponement of investments in the expansion of the distribution network. The research concludes that the full implementation of ANEEL Resolution 482/2012 becomes feasible with regulatory changes, clear rules on the technical side, greater government involvement in financial incentives and special lines of credit. For these implementations, tariff benefits could reflect positively to the captive consumers, as surplus energy injected into the network, would lead to better planning engineering companies, better sizing electrical equipment, thus optimizing the utilization rates of these goods , increasing its life and contributing to the low tariffs
2

High gain Boost converter based on the bidirectional version of the three-state switching cell. / Conversor Boost de alto ganho baseado na versÃo bidirecional da cÃlula de comutaÃÃo de trÃs estados

Diego Bruno Saraiva Alves 10 October 2014 (has links)
This paper presents the study and development of a topology of nonisolated converter operating at high frequency, which is suitable for the integration of battery banks, photovoltaic panels, and a high voltage dc link in a single conversion stage. The topology is based on the bidirectional version of the three-state switching cell and is recommended for battery charging, while a 200V dc link can be obtained in a single conversion stage using photovoltaic (PV) panels. The presented converter is able to supply a 200V dc link using a battery bank and a PV array and, depending on the solar irradiance level, it is also possible to charge the batteries by using a single conversion stage. Moreover, all the switches of the converter are able to operate under zero voltage switching (ZVS) condition over a wide operation range. The experimental results are obtained from a 500W laboratory prototype, which has been developed and tested in three situations: energy flow from the battery bank to the load, energy flow from the PV panel to the load; and energy flow from the panel to the battery bank, achieving the efficiency of 94,18%, 96,09% e 94,67% respectively. The high gain afforded by this topology and the excellent performance obtained in all operations mode, shows as a solution where the requirement of increasing the voltage to 200V or 400V from low input voltage energy sources, typically 12V, 24V or 48V, provided by batteries, solar panels or others sources of energy, for Uninterruptable Power Supply (UPS), or a DC link, for example. / Este trabalho tem por escopo apresentar o estudo e desenvolvimento de um conversor CC-CC nÃo isolado de trÃs portas, adequado à integraÃÃo em um Ãnico estÃgio de conversÃo: um banco de baterias, um conjunto de painÃis fotovoltaicos e o link CC. A topologia proposta apresenta um conversor boost de alto ganho baseado na versÃo bidirecional da cÃlula de comutaÃÃo de trÃs estados na qual se tem integrado um banco de baterias e um conjunto de painÃis fotovoltaicos com capacidade para gerar um barramento CC de 200V em um Ãnico estÃgio de processamento. A caracterÃstica bidirecional da topologia permite aos painÃis fotovoltaicos carregar as bateiras e alimentar a carga dependendo da incidÃncia solar. No caso de ausÃncia de sol, o banco de baterias supre a carga. Outra importante caracterÃstica deste conversor à a comutaÃÃo suave em modo ZVS para todas as chaves. Foi desenvolvido um protÃtipo experimental com potÃncia nominal de 500W de forma a validar todo o embasamento teÃrico e de simulaÃÃo apresentados. O conversor desenvolvido foi submetido a trÃs condiÃÃes: o fluxo de energia da bateria para a carga, do painel fotovoltaico para a carga e do painel para o banco de baterias, sendo obtido o rendimento de 94,18%, 96,09% e 94,67% respectivamente para cada condiÃÃo. AlÃm disso, as formas de ondas experimentais e de simulaÃÃo para cada condiÃÃo e o comparativo de rendimento de topologias, tambÃm sÃo apresentados. O alto ganho e o rendimento alcanÃado nesta topologia, a torna uma forte soluÃÃo quando hà necessidade de elevar a tensÃo a partir de baterias ou painÃis fotovoltaicos, quando os valores fornecidos por estes geralmente sÃo de 12V, 24V ou 48V. Ressalte-se que este trabalho contribui cientificamente na Ãrea da eletrÃnica de potÃncia, mais especificamente, no que concerne ao estudo e desenvolvimento de novas topologias de conversores CC-CC nÃo isolados de trÃs portas para aplicaÃÃes em energias renovÃveis.

Page generated in 0.2085 seconds