• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ocular effects following aqueocentesis in dogs using variable needle sizes: fluorophotometric and tonometric evaluation

Allbaugh, Rachel A. January 1900 (has links)
Master of Science / Department of Clinical Sciences / Amy J. Rankin / Objective – To measure blood aqueous-barrier breakdown following aqueocentesis using various needle sizes and to monitor the intraocular pressure (IOP) response. Animals – 24 healthy, adult dogs received treatment (24 treated eyes, 24 contralateral eyes); 3 dogs were untreated controls (6 control eyes). Procedures – Dogs receiving treatment were divided into 3 equal groups (25-, 27-, or 30- gauge needle aqueocentesis). In each dog the treated eye was determined randomly, the contralateral eye was untreated. Dogs that did not have aqueocentesis performed in either eye were used as controls. Aqueocentesis at the lateral limbus was performed under sedation and topical anesthesia. Anterior chamber fluorophotometry was performed before and after aqueocentesis on day 1. On days 2-5 sedation and fluorophotometry were repeated. Intraocular pressure was measured with a rebound tonometer at multiple time points. Results – Aqueocentesis resulted in blood-aqueous barrier breakdown in all treated eyes with barrier reestablishment present by day 5 detected by fluorophotometry. On day 2 the contralateral untreated eyes of all groups also showed statistically significant increased fluorescence (P < 0.05) following treatment of the opposite eye, but these values were not statistically significantly greater than untreated controls. In treated eyes there was no statistical difference in fluorescein concentration or IOP between 27- and 30-gauge needles. Use of the 25- gauge needle resulted in a statistically significant increase in anterior chamber fluorescence on days 3 and 5. It also caused a statistically significant increase in IOP 20 minutes following aqueocentesis as compared to the 27- and 30-gauge needles. Aside from this transient ocular hypertension, rapid resolution of ocular hypotony following aqueocentesis was observed in all treatment groups. Conclusions and Clinical Relevance – Aqueocentesis using a 25-gauge needle resulted in a greater degree of blood-aqueous barrier breakdown and a brief state of intraocular hypertension following paracentesis. Use of a 27- or 30-gauge needle is recommended for aqueous paracentesis. A consensual ocular reaction appeared to occur in dogs following unilateral traumatic blood-aqueous barrier breakdown and may be of clinical significance. Statistical significance was limited in this study due to high variability and large standard deviations.
2

Avaliação da viabilidade da técnica de acesso ao espaço epicárdico por punção transatrial para ablação epicárdica por catete / Percutaneous transatrial approach to reach the epicardial space for epicardial mapping and ablation

Venancio, Ana Claudia 20 January 2011 (has links)
Fundamentos O acesso percutâneo ao espaço pericárdico pela via transatrial poderia ser uma alternativa ao acesso subxifóide para o mapeamento e ablação de fibras miocárdicas subepicárdicas. O objetivo deste estudo foi avaliar a viabilidade de alcançar o espaço pericárdico normal através do apêndice auricular direito (AAD) por acesso transvenoso. Métodos e Resultados - Um sistema Mullins (8F), originalmente desenvolvido para alcançar o átrio esquerdo (AE) por punção transeptal foi utilizado neste estudo para transfixar o AAD (16) ou AE (1) em 17 suínos, com uma média de 26,9 ± 2,6 kg, e alcançar o espaço pericárdico normal. Um cateter 7F quadripolar com eletrodo distal com 4 ou 8 mm foi introduzido no espaço pericárdico para aplicações de radiofrequência. Em 15 (88%) animais o procedimento foi realizado sem instabilidade hemodinâmica (PA média inicial = 80,4 ± 11.7 mmHg; PA média final = 86,8 ± 9.7 mmHg, p = 0,11). Foi identificado e aspirado derrame pericárdico discreto (28,9 ± 27.6 ml/animal) durante o procedimento. O espaço pericárdico foi acidentalmente acessado por punção do ventrículo direito (VD) em um animal e por punção do anel da valva tricúspide em outro. Ambos apresentaram sangramento xii pericárdico importante e tamponamento cardíaco. Um dispositivo para oclusão do orifício de perfuração foi testado com sucesso em três porcos, dois no AD e um no VD, sem ocorrência de derrame pericárdico significativo. Conclusões O acesso transatrial ao espaço pericárdico pode ser potencialmente útil para mapeamento e ablação de arritmias cardíacas, bem como para drenagem imediata de um tamponamento cardíaco agudo / Background A transvenous access to the pericardial space could provide a convenient route to map and ablate subepicardial myocardial fibers. The aim of this study was to evaluate the feasibility of reaching the normal pericardial space through the right atrial appendage (RAA) by transvenous access. Methods and Results An 8F Mullins system was used to transfix the right atrium (16) and left atrium (1) in 17 pigs with a mean of 26.9 ± 2.6 kg. A 7F quadripolar catheter with 4 or 8 mm distal tip electrode was introduced into the pericardial space to perform epicardial radiofrequency lesions. The pericardial space was successfully reached in 15 (88%) animals without hemodynamic instability (initial mean BP 80.4 ± 11.7 mmHg; final 86.8 ± 9.7 mmHg, p= 0,11). However, a mild pericardial serohemorrhagic effusion was identified and aspirated in all the animals (28.9 ± 27.6 ml/pig) during the procedure. The pericardial space was accidentally accessed through the right ventricle (RV) in one animal and through the tricuspid annulus in another, which presented important pericardial bleeding and cardiac tamponade. The hypothesis that an occlusion device could be useful to close the created atrial xiv orifice was tested successfully in thee pigs (two at RAA and one at RV) and without significant pericardial bleeding. Conclusions The right atrial appendage route might be potentially useful to access the normal pericardial space for mapping and ablating cardiac arrhythmias as well as to drain promptly an acute tamponade
3

Avaliação da viabilidade da técnica de acesso ao espaço epicárdico por punção transatrial para ablação epicárdica por catete / Percutaneous transatrial approach to reach the epicardial space for epicardial mapping and ablation

Ana Claudia Venancio 20 January 2011 (has links)
Fundamentos O acesso percutâneo ao espaço pericárdico pela via transatrial poderia ser uma alternativa ao acesso subxifóide para o mapeamento e ablação de fibras miocárdicas subepicárdicas. O objetivo deste estudo foi avaliar a viabilidade de alcançar o espaço pericárdico normal através do apêndice auricular direito (AAD) por acesso transvenoso. Métodos e Resultados - Um sistema Mullins (8F), originalmente desenvolvido para alcançar o átrio esquerdo (AE) por punção transeptal foi utilizado neste estudo para transfixar o AAD (16) ou AE (1) em 17 suínos, com uma média de 26,9 ± 2,6 kg, e alcançar o espaço pericárdico normal. Um cateter 7F quadripolar com eletrodo distal com 4 ou 8 mm foi introduzido no espaço pericárdico para aplicações de radiofrequência. Em 15 (88%) animais o procedimento foi realizado sem instabilidade hemodinâmica (PA média inicial = 80,4 ± 11.7 mmHg; PA média final = 86,8 ± 9.7 mmHg, p = 0,11). Foi identificado e aspirado derrame pericárdico discreto (28,9 ± 27.6 ml/animal) durante o procedimento. O espaço pericárdico foi acidentalmente acessado por punção do ventrículo direito (VD) em um animal e por punção do anel da valva tricúspide em outro. Ambos apresentaram sangramento xii pericárdico importante e tamponamento cardíaco. Um dispositivo para oclusão do orifício de perfuração foi testado com sucesso em três porcos, dois no AD e um no VD, sem ocorrência de derrame pericárdico significativo. Conclusões O acesso transatrial ao espaço pericárdico pode ser potencialmente útil para mapeamento e ablação de arritmias cardíacas, bem como para drenagem imediata de um tamponamento cardíaco agudo / Background A transvenous access to the pericardial space could provide a convenient route to map and ablate subepicardial myocardial fibers. The aim of this study was to evaluate the feasibility of reaching the normal pericardial space through the right atrial appendage (RAA) by transvenous access. Methods and Results An 8F Mullins system was used to transfix the right atrium (16) and left atrium (1) in 17 pigs with a mean of 26.9 ± 2.6 kg. A 7F quadripolar catheter with 4 or 8 mm distal tip electrode was introduced into the pericardial space to perform epicardial radiofrequency lesions. The pericardial space was successfully reached in 15 (88%) animals without hemodynamic instability (initial mean BP 80.4 ± 11.7 mmHg; final 86.8 ± 9.7 mmHg, p= 0,11). However, a mild pericardial serohemorrhagic effusion was identified and aspirated in all the animals (28.9 ± 27.6 ml/pig) during the procedure. The pericardial space was accidentally accessed through the right ventricle (RV) in one animal and through the tricuspid annulus in another, which presented important pericardial bleeding and cardiac tamponade. The hypothesis that an occlusion device could be useful to close the created atrial xiv orifice was tested successfully in thee pigs (two at RAA and one at RV) and without significant pericardial bleeding. Conclusions The right atrial appendage route might be potentially useful to access the normal pericardial space for mapping and ablating cardiac arrhythmias as well as to drain promptly an acute tamponade

Page generated in 0.0823 seconds