• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal / Análise endotelial da córnea em pacientes submetidos à cirurgia corneal pela técnica de anel intraestromal / Corneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromal / Corneal endothelial analysis in patients undergoing corneal surgery technique for ring intrastromal

SILVA, Rodrigo Salustiano Corrêa e 12 June 2012 (has links)
Made available in DSpace on 2014-07-29T15:25:21Z (GMT). No. of bitstreams: 1 tesedefendidarodrigo.pdf: 1424160 bytes, checksum: ba481cb9361d272aa1bf192493e601ce (MD5) Previous issue date: 2012-06-12 / To evaluate corneal endothelium by means of specular microscopy exam in patients with keratoconus, before and after Cornealring® corneal intrastromal ring surgery. A hundred and two eyes of sixty-seven patients, aged between 12 and 45, with the average age of 27,31 ± 8,15 years, 30 of whom females and 37 males, were selected to be submitted to the implant of Cornealring® corneal ring segments and evaluation of the corneal endothelium in the pre and post surgery (six months after the procedure) in the External Diseases and Cornea Ward of the Instituto Panamericano da Visão. Data have been stored for later analysis by software SPSS (Statistical Package of Social Science) for Windows 15.0. Only the eyes receiving two rings with 250 μ thickness showed significant statistical difference (p = 0,008). The remaining eyes showed no statistical difference (initial x final). In relation to the thickness and to the number of implanted rings, a decrease in the final coefficient was observed in most implanted rings. However, only the eyes that received two rings 250 μ thick showed significant difference (p=0,003), with a decrease of 10,1% in the coefficients of variation average. In relation to the thickness and number of implanted rings, a decrease in the percentage of hexagonal cells was observed (before and after surgery). Only the eyes that received two rings 250 μ thick showed a highly significant decrease (p=0,001) in relation to the hexagonal percentage of 9,7%. Although the parameters in the specular microscopy showed alterations mainly in the thicker rings, all the patients showed transparent corneas without clinical signs of endothelial suffering along the six months of follow-up. A longer period of study must be considered for better understanding and interpretation of the results obtained, in order to establish any relationship between eventual complications and the thickness of the implanted ring. / A tese tem por objetivo avaliar o endotélio corneal por meio de microscopia especular, de pacientes portadores de ceratocone, antes e após a cirurgia corneal pela técnica de anel intraestromal, utilizando o implante Cornealring®. Cento e dois olhos de 67 pacientes, com idade entre 12 e 45 anos (com média 27,31 ± 8,15 anos), sendo 30 do sexo feminino e 37 do sexo masculino, foram selecionados para serem submetidos ao implante dos segmentos do anel Cornealring® e avaliação do endotélio corneal no pré e pós-operatório, seis meses após o procedimento, no serviço de Doenças Externas e Córnea do Instituto Panamericano da Visão. Os dados foram armazenados, para posterior análise no software Statistical Package of Social Science (SPSS) para Windows, versão 15.0. Apenas os olhos que receberam dois anéis de espessura de 250 μ apresentaram diferença estatisticamente significativa da densidade endotelial (p = 0,008). Nos demais olhos, não houve diferença estatística (antes e após a cirurgia corneal). Notou-se que, na maioria das espessuras de anéis utilizados, houve uma diminuição do coeficiente de variação após a cirurgia corneal. Porém, só os olhos que receberam dois anéis de espessuras de 250 μ mostraram diferença significativa (p=0,003), com uma diminuição de 10,1% na média do coeficiente de variação. Observou-se diminuição no percentual de células hexagonais em relação, no tocante à espessura e à quantidade de anéis implantados. Somente os olhos que receberam os dois anéis de espessura de 250 μ mostraram diminuição altamente significativa (p=0,001), em relação ao percentual hexagonal de 9,7%. Apesar de os parâmetros na microscopia especular mostrarem-se alterados, sobretudo nos anéis com espessura maior, todos os pacientes apresentaram córneas transparentes sem sinais clínicos de sofrimento endotelial ao longo dos seis meses de seguimento. Maior tempo de estudo deve ser considerado para melhor compreensão e interpretação dos resultados encontrados, a fim de ser estabelecida alguma relação entre possíveis complicações e a espessura do anel implantado.

Page generated in 0.1149 seconds