• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Variabilidade espacial e temporal de atributos hidrológicos para gerenciamento de recursos hídricos em aluvião no semi- árido sob uso agrícola

ANDRADE, Tafnes da Silva 11 March 2010 (has links)
Submitted by (lucia.rodrigues@ufrpe.br) on 2016-10-18T13:08:46Z No. of bitstreams: 1 Tafnes da Silva Andrade.pdf: 1998504 bytes, checksum: 836c41e92b9859b73b5759933ff5ff25 (MD5) / Made available in DSpace on 2016-10-18T13:08:46Z (GMT). No. of bitstreams: 1 Tafnes da Silva Andrade.pdf: 1998504 bytes, checksum: 836c41e92b9859b73b5759933ff5ff25 (MD5) Previous issue date: 2010-03-11 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The rivers alluvial valleys, formed by deposition of sediments and eroded materials are predominantly sandy, and usually form good aquifers. In areas where irrigated agriculture is practiced, the recovery of the water alluvial reserves, may occur due to precipitation and / or irrigation. The recharge can be estimated from information of the variation of water depth as piezometers, or whenever there is positive changes in groundwater level is an episode of recharge can be quantified. This paper aims to present the results of monitoring of changes in groundwater levels and estimate the alluvial valley recharge factor by the temporary streams Mimoso, Jatoba and Ipaneminha, from January 2002 to September 2009 in the Pernambuco semiarid. We used monthly data of the piezometric levels monitoring, from January 2002 to October 2009, retrieved from the database of the Water and Soil Laboratory of UFRPE that performs this monitoring since September 2001. From the monitoring of piezometric levels, can be seen that the system responds to significant precipitation events, only the monthly precipitation above 100mm promote recharge and there is no significant difference between charges that occurred in a loam soil and sandy-loam. / Os vales aluviais dos rios, formados pela deposição de sedimentos fluviais e materiais erodidos, são predominantemente arenosos, e se constituem, normalmente, em bons aqüíferos. Em áreas onde se pratica agricultura irrigada, a recuperação das reservas hídricas do aluvião, pode ocorrer devido à precipitação e/ou irrigação. A recarga pode ser avaliada a partir de informação da variação da profundidade da água medida em piezômetros, ou seja, sempre que há variações positivas no nível freático ocorre um episódio de recarga possível de quantificar. Este trabalho tem como objetivos apresentar os resultados do monitoramento da variação dos níveis freáticos e estimar o fator de recarga do vale aluvial pelos riachos temporários Mimoso, Jatobá e Ipaneminha, no período de janeiro de 2002 a setembro de 2009, em região semi-árida de Pernambuco. Foram utilizados dados mensais, do monitoramento dos níveis piezométricos, do período de Janeiro de 2002 e outubro de 2009, obtidos a partir do banco de dados do Laboratório de Água e Solo da UFRPE, que realiza esse acompanhamento desde setembro 2001. A partir do monitoramento dos níveis piezométricos, pode-se verificar que o sistema responde significativamente a eventos de precipitação, que apenas as precipitações mensais acima de 100mm promovem recarga e que não existe diferença significativa entre as recargas ocorridas em solos de textura franco e franco-arenosa.
2

Condutividade hidráulica de solos compactados em ensaios com permeâmetro de parede flexível / Hydraulic conductivity of compacted soils in flexible wall permeameter tests

Alonso, Thiago de Paula 16 September 2005 (has links)
Cincos solos compactados do estado de São Paulo foram estudados para uso como barreira impermeável de aterros sanitários. Foram realizados ensaios em permeâmetro de parede flexível com utilização do sistema de controle hidráulico de volume constante (sistema fechado), ensaios em permeâmetro de parede rígida e ensaios de contração. Verificou-se que menores valores de condutividade hidráulica estão associados a teores de umidade de moldagem igual ou acima do teor de umidade ótimo fornecida no ensaio de Proctor normal. Teores de umidade acima do ótimo e graus de compactação superiores a 100% não causaram significativas reduções na condutividade hidráulica, que tende a se estabilizar a partir destes parâmetros. Foram sugeridas condições de compactação para quatro dos cinco solos analisados, de forma que a condutividade hidráulica não excedesse 1.'10 POT.-7' cm/s, valor sugerido para barreiras impermeáveis. A contração axial e volumétrica não foi influenciada pelo teor de umidade de moldagem e grau de compactação, para corpos-de-prova compactados nas condições de compactação sugeridas. Os resultados de condutividade hidráulica em ensaios com permeâmetros de parede rígida se mostraram, aproximadamente, uma ordem de grandeza menor se comparados aos resultados obtidos com permeâmetro de parede flexível, porém essa diferença diminuiu com o aumento do grau de compactação dos corpos-de-prova / The hydraulic conductivity of five compacted soils from São Paulo state is studied aiming at their use in lining systems. Permeability tests were performed in flexible wall permeameters with constant volume hydraulic control system (closed system), rigid wall permeameters and contraction tests. It was verified that lower values of hydraulic conductivity are associated to molding water content equal or larger than optimum water content of soil as measured in standard Proctor. Molding water content beyond optimum and compaction degree lager than 100% did not cause significant reduction on hydraulic conductivity, which tends to stabilize when those parameters are reached. It is proposed ideal conditions of compaction for four of five compacted soils studied with hydraulic conductivity not lager than '10 POT.-7' cm/s, suggested value for lining systems. The axial and volumetric shrinkage was not influenced by water content and compaction degree, for specimen compacted on ideal conditions suggested here. The hydraulic conductivity results of greatness lower when compared to the results of the flexible wall permeameter, although that difference gets smaller with the rise of compaction degree
3

Estudo da condutividade hidráulica em solos não saturados / not available

Alfaro Soto, Miguel Angel 26 April 1999 (has links)
A condutividade hidráulica de dois solos não saturados típicos da região de São Carlos, um arenoso e outro argiloso é estudada através de ensaios de campo empregando o permeâmetro Guelph. Duas alternativas de ensaio foram empregadas e os resultados experimentais foram analisados com os modelo teóricos de REYNOLDS e ELRICK (1985) e PHILIP (1985). Paralelamente, obtiveram-se em laboratório curvas de retenção de água dos solos o que possibilitou determinar a função condutividade hidráulica através das fórmulas empíricas de VAN GENUCHTEN, (1980) e de GARDNER (1958). As características e a variação dos valores da condutividade hidráulica não saturada de campo fornecidos pelo permeâmetro Guelph, são discutidos e confrontados com aqueles obtidos a partir dos métodos indiretos provenientes de laboratório. Observou-se que as condutividades hidráulicas saturadas nos solos foram praticamente iguais, quer se considerem os resultados de campo ou laboratório. Os resultados de campo mostraram-se mais consistentes para o solo argiloso qualquer que tenha sido a técnica de ensaio. O parâmetro &#945 da equação de GARDNER (1958) obtido no campo resultou maior que o valor sugerido na literatura ou obtido em laboratório para o solo arenoso. Para o solo argiloso, todas as opções de obtenção do parâmetro tenderam a fornecer valores praticamente iguais. / The unsaturated hydraulic conductivity of two typical soils from the region of São Carlos City, sandy and clayey soils, has been studied through field tests using the Guelph permeameter. Two different alternatives of tests have been performed and the experimental data have been analyzed following the theoretical models from REYNOLDS and ELRICK (1985) and PHILIP (1985). However, soil-water characteristic curves were obtained in such a way that the hydraulic conductivity function could be evaluated using the empirical expressions from VAN GENUCHTEN (1980), and GARDNER (1958). The characteristics and the variation of the field unsaturated hydraulic conductivity values from the Guelph permeameter are discussed and compared to those from laboratory indirect methods. The field results showed to be more consistent to the clayey soil independent on the test or calculation method. The &#945 value (GARDNER, 1958) parameter obtained in the fields was Iarger than the values suggested in the literature or obtained in laboratory for the sandy soil. To the clayey soil, all the obtaining options of the parameter tended to supply values quite the same.
4

AVALIAÇÃO DA RELAÇÃO ENTRE A CONDUTIVIDADE HIDRÁULICA DO SOLO SATURADO COM PARÂMETROS FÍSICOS DE UM LATOSSOLO VERMELHO DISTRÓFICO SUBMETIDO A DOIS DIFERENTES MANEJOS

Ferreira, Silvana Travinski 03 July 2008 (has links)
Made available in DSpace on 2017-07-21T19:25:56Z (GMT). No. of bitstreams: 1 SilvanaTravinski.pdf: 2793954 bytes, checksum: d9b67ec4fc80683573196ad7d86cd258 (MD5) Previous issue date: 2008-07-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Some soil physical properties alter due to the management conducted on them. It is the management that largely produces the main modifications in the soil structure. Soil non harvest and conventional managements are the more investigated cultivation methods. Non harvest appeared as an alternative to the conventional, nevertheless, comparative studies of the alterations produced by those two types of management systems can supply important subsidies in the analysis of the advantages and disadvantages of a system in relation to the other. The objective of this work was to compare the saturated soil hydraulic conductivity of a Red Latossol submitted to non harvest, conventional tillage and secondary forest and, to correlate it to other physical properties of the soil, such as soil particle density, soil particle distribution (sand, silte and clay), soil bulk density, soil micro and macro porosity. The saturated soil hydraulic conductivity was obtained using a Guelph permeameter. A rectangular mesh composed of 35 measurement positions was used. The investigated physical properties were analyzed using the classical statistics, which is based on the calculation of averages, standard deviation, variation coefficient, minimum and maximum values and asymmetry and curtosys coefficients. Also, there were made histograms to verify the nature of the distribution and the variability of the measured variables and boxplot graphs to identify discrepant points. For a visualization of their variability, maps of these properties were performed. As compared to the non harvest, the conventional tillage system presented a larger saturated soil hydraulic conductivity. The soil saturated hydraulic conductivity did not present correlation with no other properties of the soil than soil macroporosity, for both investigated soil tillage management. / Algumas propriedades físicas do solo sofrem alterações devido ao manejo nele empregado. É o manejo que em grande parte produz as principais modificações na estrutura dos solos. Os sistemas de manejo do solo mais pesquisados são os plantio direto e o convencional. O plantio direto surgiu como uma alternativa ao convencional, portanto, estudos comparativos das alterações produzidas pelos dois tipos de sistemas de manejo mencionados podem fornecer subsídios importantes na análise das vantagens e desvantagens de um sistema em relação ao outro. O objetivo deste trabalho foi o de determinar a condutividade hidráulica do solo saturado de um Latossolo Vermelho distrófico submetido ao sistema de manejo em plantio direto, plantio convencional e floresta secundária (área que está em estágio de sucessão vegetacional) e, correlacionar essa condutividade hidráulica com outras propriedades físicas do solo, tais como a densidade de partículas, as frações granulométricas (areia, silte e argila), a densidade do solo, a porosidade total do solo, a microporosidade e a macroporosidade do solo. O parâmetro condutividade hidráulica do solo saturado foi obtida com o uso do permeâmetro de Guelph. Utilizou-se uma malha retangular composta de 35 pontos amostrais. As propriedades físicas investigadas foram analisadas utilizando-se a estatística clássica, a qual está baseada no cálculo de médias, desvio padrão, coeficiente de variação, valores mínimo e máximo e coeficientes de assimetria e curtose. Juntamente com essa análise foram feitos os histogramas para verificar a natureza da distribuição e a variabilidade das variáveis levantadas e gráfico boxplot para identificar pontos discrepantes. Para uma visualização do seu comportamento espacial, mapas das propriedades de cada sistema de manejo foram categorizados. Com o permeâmetro de Guelph foi possível determinar que o sistema plantio convencional apresentou valores médios maiores do que o plantio direto. A condutividade hidráulica do solo saturado não apresentou correlação com as demais propriedades do solo. Somente os valores médios da condutividade hidráulica do solo saturado, nos sistemas plantio direto e convencional apresentaram correlação com os valores médios da macroporosidade do solo.
5

Condutividade hidráulica de materiais de baixa permeabilidade: desenvolvimento, construção e teste de um sistema de medida / Hydraulic conductivity of low permeability materials: development, construction and test of a measurement system

Dourado, Kleber Azevedo 19 September 2003 (has links)
Este trabalho trata do desenvolvimento, montagem e teste de equipamentos para ensaios de materiais de baixa condutividade hidráulica, o qual inclui sistemas de controle hidráulico de volume constante, permeâmetros do tipo parede flexível e interfaces água-percolante. A vantagem desse arranjo está no maior controle dos ensaios e, notadamente, na redução do tempo de ensaio com emprego do sistema hidráulico de volume constante (sistema fechado), quando comparado aos ensaios que empregam o sistema aberto de controle hidráulico. Para testar o equipamento, foram ensaiados geocompostos bentoníticos (geosynthetic clay liners - GCLs) de fabricação nacional, em corpos de prova moldados com diâmetro de 100 mm e também, em uma mistura de solo com bentonita. Os resultados da condutividade hidráulica obtidos para os geocompostos bentoníticos se situaram na ordem de \'10 POT.-9\' e \'10 POT.-10\' cm/s, compatíveis com os publicados na literatura sobre o material, e os ensaios na mistura solo-bentonita produziu resultados na ordem de \'10 POT.-8\' cm/s, e foram conseguidos com cerca de 3 horas de ensaio. Aborda-se ainda a aplicabilidade da lei de Darcy aos materiais ensaiados. / This work describes the development, construction, calibration and test of equipment for testing low hydraulic conductivity materials, which includes constant volume hydraulic control system, flexible wall permeameters and permeating water interfaces. The advantage of this kind of apparatus is the greater test control, notably, the reduction of test duration due to the use of a constant volume hydraulic system (closed system), when compared to the opened system hydraulic control test. In order to test the equipment, geosynthetic clay liners (GCLs) manufactured in Brazil was used as test specimens of 100 mm diameter and also, a mixture of soil and bentonite. The results of hydraulic conductivity obtained for the GCL were in the range of \'10 POT.-9\' to \'10 POT.-10\' cm/s, comparable to what has been published by the specialized literature on this material, and the tests with the soil-bentonite mixture resulted in a conductivity about \'10 POT.-8\' cm/s, after 3 hours running the test. The applicability of Darcy´s law to the tested materials is also referred to.
6

Condutividade hidráulica de materiais de baixa permeabilidade: desenvolvimento, construção e teste de um sistema de medida / Hydraulic conductivity of low permeability materials: development, construction and test of a measurement system

Kleber Azevedo Dourado 19 September 2003 (has links)
Este trabalho trata do desenvolvimento, montagem e teste de equipamentos para ensaios de materiais de baixa condutividade hidráulica, o qual inclui sistemas de controle hidráulico de volume constante, permeâmetros do tipo parede flexível e interfaces água-percolante. A vantagem desse arranjo está no maior controle dos ensaios e, notadamente, na redução do tempo de ensaio com emprego do sistema hidráulico de volume constante (sistema fechado), quando comparado aos ensaios que empregam o sistema aberto de controle hidráulico. Para testar o equipamento, foram ensaiados geocompostos bentoníticos (geosynthetic clay liners - GCLs) de fabricação nacional, em corpos de prova moldados com diâmetro de 100 mm e também, em uma mistura de solo com bentonita. Os resultados da condutividade hidráulica obtidos para os geocompostos bentoníticos se situaram na ordem de \'10 POT.-9\' e \'10 POT.-10\' cm/s, compatíveis com os publicados na literatura sobre o material, e os ensaios na mistura solo-bentonita produziu resultados na ordem de \'10 POT.-8\' cm/s, e foram conseguidos com cerca de 3 horas de ensaio. Aborda-se ainda a aplicabilidade da lei de Darcy aos materiais ensaiados. / This work describes the development, construction, calibration and test of equipment for testing low hydraulic conductivity materials, which includes constant volume hydraulic control system, flexible wall permeameters and permeating water interfaces. The advantage of this kind of apparatus is the greater test control, notably, the reduction of test duration due to the use of a constant volume hydraulic system (closed system), when compared to the opened system hydraulic control test. In order to test the equipment, geosynthetic clay liners (GCLs) manufactured in Brazil was used as test specimens of 100 mm diameter and also, a mixture of soil and bentonite. The results of hydraulic conductivity obtained for the GCL were in the range of \'10 POT.-9\' to \'10 POT.-10\' cm/s, comparable to what has been published by the specialized literature on this material, and the tests with the soil-bentonite mixture resulted in a conductivity about \'10 POT.-8\' cm/s, after 3 hours running the test. The applicability of Darcy´s law to the tested materials is also referred to.
7

Condutividade hidráulica de solos compactados em ensaios com permeâmetro de parede flexível / Hydraulic conductivity of compacted soils in flexible wall permeameter tests

Thiago de Paula Alonso 16 September 2005 (has links)
Cincos solos compactados do estado de São Paulo foram estudados para uso como barreira impermeável de aterros sanitários. Foram realizados ensaios em permeâmetro de parede flexível com utilização do sistema de controle hidráulico de volume constante (sistema fechado), ensaios em permeâmetro de parede rígida e ensaios de contração. Verificou-se que menores valores de condutividade hidráulica estão associados a teores de umidade de moldagem igual ou acima do teor de umidade ótimo fornecida no ensaio de Proctor normal. Teores de umidade acima do ótimo e graus de compactação superiores a 100% não causaram significativas reduções na condutividade hidráulica, que tende a se estabilizar a partir destes parâmetros. Foram sugeridas condições de compactação para quatro dos cinco solos analisados, de forma que a condutividade hidráulica não excedesse 1.'10 POT.-7' cm/s, valor sugerido para barreiras impermeáveis. A contração axial e volumétrica não foi influenciada pelo teor de umidade de moldagem e grau de compactação, para corpos-de-prova compactados nas condições de compactação sugeridas. Os resultados de condutividade hidráulica em ensaios com permeâmetros de parede rígida se mostraram, aproximadamente, uma ordem de grandeza menor se comparados aos resultados obtidos com permeâmetro de parede flexível, porém essa diferença diminuiu com o aumento do grau de compactação dos corpos-de-prova / The hydraulic conductivity of five compacted soils from São Paulo state is studied aiming at their use in lining systems. Permeability tests were performed in flexible wall permeameters with constant volume hydraulic control system (closed system), rigid wall permeameters and contraction tests. It was verified that lower values of hydraulic conductivity are associated to molding water content equal or larger than optimum water content of soil as measured in standard Proctor. Molding water content beyond optimum and compaction degree lager than 100% did not cause significant reduction on hydraulic conductivity, which tends to stabilize when those parameters are reached. It is proposed ideal conditions of compaction for four of five compacted soils studied with hydraulic conductivity not lager than '10 POT.-7' cm/s, suggested value for lining systems. The axial and volumetric shrinkage was not influenced by water content and compaction degree, for specimen compacted on ideal conditions suggested here. The hydraulic conductivity results of greatness lower when compared to the results of the flexible wall permeameter, although that difference gets smaller with the rise of compaction degree
8

Estudo da condutividade hidráulica em solos não saturados / not available

Miguel Angel Alfaro Soto 26 April 1999 (has links)
A condutividade hidráulica de dois solos não saturados típicos da região de São Carlos, um arenoso e outro argiloso é estudada através de ensaios de campo empregando o permeâmetro Guelph. Duas alternativas de ensaio foram empregadas e os resultados experimentais foram analisados com os modelo teóricos de REYNOLDS e ELRICK (1985) e PHILIP (1985). Paralelamente, obtiveram-se em laboratório curvas de retenção de água dos solos o que possibilitou determinar a função condutividade hidráulica através das fórmulas empíricas de VAN GENUCHTEN, (1980) e de GARDNER (1958). As características e a variação dos valores da condutividade hidráulica não saturada de campo fornecidos pelo permeâmetro Guelph, são discutidos e confrontados com aqueles obtidos a partir dos métodos indiretos provenientes de laboratório. Observou-se que as condutividades hidráulicas saturadas nos solos foram praticamente iguais, quer se considerem os resultados de campo ou laboratório. Os resultados de campo mostraram-se mais consistentes para o solo argiloso qualquer que tenha sido a técnica de ensaio. O parâmetro &#945 da equação de GARDNER (1958) obtido no campo resultou maior que o valor sugerido na literatura ou obtido em laboratório para o solo arenoso. Para o solo argiloso, todas as opções de obtenção do parâmetro tenderam a fornecer valores praticamente iguais. / The unsaturated hydraulic conductivity of two typical soils from the region of São Carlos City, sandy and clayey soils, has been studied through field tests using the Guelph permeameter. Two different alternatives of tests have been performed and the experimental data have been analyzed following the theoretical models from REYNOLDS and ELRICK (1985) and PHILIP (1985). However, soil-water characteristic curves were obtained in such a way that the hydraulic conductivity function could be evaluated using the empirical expressions from VAN GENUCHTEN (1980), and GARDNER (1958). The characteristics and the variation of the field unsaturated hydraulic conductivity values from the Guelph permeameter are discussed and compared to those from laboratory indirect methods. The field results showed to be more consistent to the clayey soil independent on the test or calculation method. The &#945 value (GARDNER, 1958) parameter obtained in the fields was Iarger than the values suggested in the literature or obtained in laboratory for the sandy soil. To the clayey soil, all the obtaining options of the parameter tended to supply values quite the same.
9

Caracterização físico-hidrica de três bacias experimentais do Estado de Pernambuco para suporte à modelagem hidrológica

SILVA, José Roberto Lopes da 05 March 2010 (has links)
Submitted by (lucia.rodrigues@ufrpe.br) on 2016-10-05T14:41:01Z No. of bitstreams: 1 Jose Roberto Lopes da Silva.pdf: 2279594 bytes, checksum: 9d16b5a4a812568f5d4017907f2695cb (MD5) / Made available in DSpace on 2016-10-05T14:41:01Z (GMT). No. of bitstreams: 1 Jose Roberto Lopes da Silva.pdf: 2279594 bytes, checksum: 9d16b5a4a812568f5d4017907f2695cb (MD5) Previous issue date: 2010-03-05 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Financiadora de Estudos e Projetos - Finep / For any study involving the movement of soil water becomes essential to know the physical and hydraulic properties and their correlations. Both proprieties are of fundamental importance in the storage and transport of water and nutrients, in controlling infiltration and runoff, as well as soil conservation. In this context, this study aimed to do a physical-water characterization of three experimental basins (Jatoba and Mimoso / Pesqueira-PE and Xaréu / Fernando Noronha-PE) in the semiarid, in order to generate information for hydrological modeling and subsidies for soil and water management and conservation. It has been evaluated the physical and hydraulic behavior of soil at different depths and vegetation cover. Physical characterization of soils was carried out by laboratory tests on disturbed and undisturbed samples. The hydraulic characterization was conducted through moisture retention curves and through of hydraulic conductivity (K) tests in the field with the Guelph permeameter. Possession of physical variables and soil organic matter pedotransfer functions (PTF) have been tested to estimate the K0 and moisture in particular tensions in order to compare field and laboratory measurements. Among the attributes analyzed, the organic matter was the one with the highest coefficient of variation in depth in the basins and Mimoso Jatoba. There was also high variability of saturated hydraulic conductivity (K0) in depth, in the three basins. It was concluded that the hydraulic conductivity no significant difference in hydraulic conductivity means has been verified for the different vegetation covers. Among soils, the Vertisol presented the highest capacity to retain water. It is concluded that the proposed PTF showed low prediction of K0. The PTF for estimatingsoil moisture, also showed low prediction for soils at Xaréu Basins. In the Jatoba and Mimoso Basins, the best prediction for soil moisture at field capacity was obtained by the model proposed by Meng et al. (1987) and the humidity at wilting point, the equation based on the mean texture proposed by Oliveira et al. (2002) showed the best performance. For the water available content for the equation based on unique data set proposed by Oliveira et al. (2002), and Massuti (1997) model showed a good prediction. / Para qualquer estudo que envolva o movimento da água no solo torna-se imprescindível o conhecimento das propriedades físicas e hidráulicas, bem como suas correlações. Ambas têm fundamental importância no armazenamento e transporte de água e de nutrientes, no controle da infiltração e escoamento superficial, bem como na conservação do solo. Nesse contexto, o presente estudo buscou realizar uma caracterização físico-hídrica de três bacias experimentais (Jatobá e Mimoso/Pesqueira-PE e Xaréu/Fernando Noronha-PE) do semiárido, a fim de gerar informações para suporte à modelagem hidrológica e subsídios para o gerenciamento e conservação do solo e da água. Avaliou-se o comportamento físico-hídrico dos solos em diferentes profundidades e coberturas vegetais. A caracterização física dos solos se deu por análises de laboratório com amostras indeformadas e deformadas. A caracterização hidráulica foi realizada por meio de curvas de retenção de umidade e através de testes de condutividade hidráulica (K) em campo com permeâmetro de Guelph. De posse das variáveis físicas e da matéria orgânica do solo, foram testadas funções de pedotransferência (FPT) para estimativa da K0 e umidade em tensões específicas, a fim de comparar com as medidas em campo e laboratório. Dentre os atributos do solo analisados, a matéria orgânica foi o que apresentou o maior coeficiente de variação, em profundidade, nas Bacias do Jatobá e do Mimoso. Verificou-se também, alta variabilidade da condutividade hidráulica do solo saturado (K0) em profundidade, nas três bacias. Concluiu-se que a condutividade hidráulica não apresentou diferença significativa entre médias, para as diferentes coberturas vegetais. Dentre os solos estudados, o Vertissolo foi o que apresentou a maior capacidade de retenção de água. Conclui-se que as FPT propostas apresentaram baixa predição da K0. As FPT para estimativa da umidade retida a potenciais específicos, também apresentaram baixa predição para os solos da Bacia do Xaréu. Nas Bacias do Jatobá e do Mimoso a melhor predição para umidade na capacidade de campo foi obtida pelo modelo de Meng et al. (1987) e para a umidade no ponto de murcha permanente, a equação baseada na textura média proposta por Oliveira et al. (2002) mostrou o melhor desempenho. Para água disponível a equação baseada no conjunto único de dados proposta por Oliveira et al. (2002), e o modelo de Massuti (1997) apresentaram boa predição.

Page generated in 0.0607 seconds