1 |
Phase Behavior and Phase Separation Kinetics in Polymer Solutions under High PressureZhang, Wei 25 April 2005 (has links)
The phase behavior and phase separation kinetics in polymer solutions in binary mixtures of supercritical carbon dioxide (CO2) and organic solvents were studied for two systems. Solutions of polyethylene (PE) in CO2 + n-pentane were selected as one model system to study both the solid-fluid (S-F) and liquid-liquid (L-L) phase transitions as well as the interplay of these two types of phase separations on the final morphological and thermal properties of PE crystals. Solutions of polysulfone (PSF) in CO2 + tetrahydrofuran (THF) were selected as another model system because of the technological importance of this membrane forming polymer and because of the broad interest in developing new solvent/non-solvent systems for forming microporous materials. These phase boundaries were determined using a high-pressure view-cell and optical techniques over a temperature range of 90-165 oC and pressures up to 55 MPa for PE/n-pentane/CO2 system, and over a temperature range of 25 to 155 oC and pressures up to 70 MPa for PSF/THF/CO2 system.
For PE solutions, it has been found that the addition of CO2 to the PE/n-pentane system shifts the L-L phase boundary to significantly higher pressures, but moves the S-F phase boundary only slightly to higher temperatures. The S-F phase boundary which represents the crystallization/melting process in the polymer solution was about 10 oC lower than the crystallization/melting temperatures of the neat polyethylene samples determined by differential scanning calorimetry (DSC). It was further found that the S-F phase boundary in n-pentane displays a unique sensitivity to the pressure-temperature conditions and moves to lower temperatures in the pressure range from 38 to 42 MPa. This effect even though not as augmented remains also for the S-F boundary in the solutions in CO2 + n-pentane mixtures.
The miscibility of PSF in THF + CO2 was investigated at CO2 levels up to 14 wt %. This system shows lower critical solution temperature (LCST)-type phase behavior at low CO2 content, which is shifted to upper critical solution temperature (UCST)-type at higher CO2 levels along with an increase in the miscibility pressures. In contrast to the PE system, this system was found to display multiple miscibility windows. A "U"-shaped phase boundary in 92 % THF + 8 % CO2 mixture was observed to transfer to a "W"-shaped phase boundary at 10 wt % CO2, which was further separated into a double "U"-shaped phase boundary at 13 wt % CO2. The specific volume of the polysulfone solutions were found to display a variation parallel to this changing pattern in the phase boundaries, with reduced miscibility being accompanied with an increase in the specific volume.
The phase separation kinetics in these two polymer solutions were investigated using time- and angle-resolved light scattering techniques. With the PE solutions, the focus was on the kinetics of S-F phase separation (crystallization) and miscibility and (melting) in n-pentane. Experiments were conducted with relatively dilute solutions at concentrations up to 2.3 wt %. The results show that the crystallization which was induced by cooling at constant pressure is dominated by a nucleation and growth process. In the majority of the experiments the particle growth process was observed to last for about 1 minute with a slight dependence on the crystallization pressure.
The phase separation kinetics in PSF solutions were conducted only in a solvent mixture containing 90 wt % THF and 10 wt % CO2. Polymer concentrations were varied up to 3.3 wt %. This system was also observed to undergo phase separation by only nucleation and growth mechanism under these conditions upon reducing the pressure at constant temperature. Several experiments were conducted using a multiple rapid pressure drop technique to identify the depth of the metastable region.
PE crystals that were produced by crossing the S-F boundary by different paths were collected and characterized by field emission scanning electron microscopy (FESEM) and DSC. Crystallization was carried out either by cooling at constant pressure, or by cooling without pressure adjustment, or by first crossing the L-L boundary via pressure reduction at a constant temperature followed by cooling. For crystal recovery, the system was depressurized to ambient conditions irrespective of the path. It was found that all of the crystals formed from these solutions show multiple melting peaks in their first DSC heating scans, which however collapse into one crystallization peak in the cooling scans and one melting peak in the second heating scans. The temperatures corresponding to the multiple melting peaks were lower than the single melting temperature of the original PE sample and the melting temperature observed in the second heating scans for all samples. The multiple melting peaks were attributed to the presence of different lamellar thickness that are formed in the crystallization, final depressurization and sample collection stages. Depending upon the crystallization path some differences were noted. The crystals formed by first going through L-L phase separation displayed predominately double melting peaks in the first DSC scan. It was observed that the overall crystallinity is increased by more than 10 % to about 75 % compared to the crystallinity of the original PE sample, which is about 63 %.
FESEM characterization showed that the prevailing morphology is composed of plate-like lamellae that show different level of agglomeration depending on the crystallization conditions. The overall structures of the particles were ellipsoid for crystals formed from dilute solutions. For crystals formed from the 1% PE solution, crystal sizes ranged from 4 mm ´ 10 mm for crystals formed at 14 MPa to 30 mm ´ 45 mm at 45 MPa. The crystals formed from 5 wt % solutions in n-pentane at pressures in the range of 38-54 MPa showed different morphologies with features of shish-kebab like structures which were however absent in crystals formed from n-pentane + CO2 solutions. The crystals that were formed from first crossing the L-L phase boundary followed by cooling showed two distinct particle size ranges that were attributed to crystals formed from the polymer-rich and polymer-lean phases that evolve when the L-L phase boundary is crossed. / Ph. D.
|
2 |
Solution-casting of Disulfonated Poly(arylene ether sulfone) Multiblock Copolymer Films for Proton Exchange MembranesLee, Myoungbae 09 June 2009 (has links)
The overall objective of the project, on which this thesis is based, is to develop a novel hydrocarbon-based proton exchange membrane (PEM) material that can produce a proton conductivity of 0.1 S/cm at the operating conditions of 50 % relative humidity and 120 oC, which is the performance target set by the U.S. DOE for automotive application. As a part of this project, our efforts have been focused on the investigation of the effects of solution-casting conditions on the final morphology and properties of disulfonated poly(arylene ether sulfone) multiblock copolymer films from the viewpoint of phase separation of block copolymers. Of equal importance to this work, is a possibility of utilizing a rheological technique for monitoring the transformation and kinetics of block copolymers during solvent removal process, which was initially examined in order to provide fundamental quantitative understanding and practical information on the solvent removal process.
Our results demonstrated that solvent selectivity and drying temperature as well as the block length had considerable effects on the final morphology and properties. The proton conductivity could be significantly increased by simply utilizing a selective solvent, dimethylacetamide (DMAC), which is good and marginal for the sulfonated and unsulfonated blocks, respectively, rather than N-methyl-2-pyrrolidone (NMP), a neutral solvent for both blocks. The drying temperature was also observed to have considerable effects on the final properties, being coupled with the effects of solvent selectivity. Also, it was shown that the multiblock copolymer consisting of longer blocks was more sensitive to the processing conditions. From the morphological study using transmission electron microscopy and small-angle X-ray scattering, evidences for the above observations were obtained.
In the second part of this dissertation, the evolution of GÎ and GË of the solutions of a styrene-butadiene-styrene (SBS) triblock copolymer in toluene was obtained as a function of concentration using a modified parallel-plate device and a rheology test scheme developed in this study in an effort to quantify the phase separation kinetics. Then, the information on the phase transformation and kinetics of the SBS block copolymer in the solution was obtained by analyzing the GÎ and GË data with the Avrami equation. The Avrami exponent was found to be approximately 1, which indicates that the phase transformation occurred by a one-dimensional growth mechanism. The rate constant showed a strong concentration-dependence. After the initial increase up to 45 vol %, the rate constant drastically decreased and, finally, converged to 0 at 70 vol %. It is believed that, at the concentration range below 45 vol %, the phase separation became more intense as the polymer molecules had more chances to interact owing to the concentration increase. However, above 45 vol %, the phase transformation became weaker due to the limited mobility of the polymer molecules, which finally led to a “kinetically frozen-in” structure, in which the polymer molecules could not move any longer. Thus, it can be concluded that the solvent removal rate is one of the dominant factors that decide the final microstructures of solution-cast block copolymer films. / Ph. D.
|
Page generated in 0.1187 seconds