• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 2
  • 1
  • Tagged with
  • 52
  • 45
  • 44
  • 22
  • 21
  • 19
  • 19
  • 18
  • 18
  • 16
  • 15
  • 15
  • 13
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Hotel Wipeout s wellness / Hotel Wipeout with wellness

Večeřová, Gabriela January 2020 (has links)
The thesis is dealing with the proposal and processing of project documentation of the Wipeout hotel with the wellness. The proposed object is located in the uptown of Jedovnice. It is a four-storey basement building with vegetation roof and five pitched gabled roofs. The object is visually divided into two parts. The first part is covered with a chipped stone facade. The second part is covered with ventilated facade of wooden blocks of Nordic pine. The foundations of the building are reinforced concrete. Framework, peripheral and dividing walls are designed from POROTHERM system. Ceiling structures are reinforced concrete. The visual idea is the Nordic style, that fits into the surrounding landscape. The object consists of three operating parts namely a restaurant, wellness centre and temporary accommodation.
42

Optimalizace lehkého šikmého střešního pláště k redukci letních tepelných zisků / Optimization of a lightweight pitched roof in order to reduce summer heat gains

Svobodová, Sylvia January 2020 (has links)
The thesis deals with the topic of overheating of attic rooms during the summer period. In vast majority of family houses and apartment houses with inhabited attic spaces is the roof solved as lightweight. This kind of roof assembly is not able to sufficiently resist the summer boundary conditions and leads to increased heat gains in the interior. In this work, the attention is drawn entirely to the heat penetration through the roof. Different aspects of passive cooling were applied to the roof and the impact of each change was assessed. This concerns the color of the tiles, thermal accumulation, reflective surfaces and the ventilated air layer. The temperature and velocity profiles in the ventilated cavity were monitored and an analysis of the ventilated cavity efficiency was conducted. For individual analyses was used software – based on the principles of the Finite Element Method or the dynamic simulation software. Also other methods were employed: long-term measurement of temperatures on roof models; short-term measurement of surface temperature of various kinds of roof tiles; and laboratory measurement of reflexivity. Also the effect of insect grilles on the air flow is discussed; which was tested on a ventilator track. In this publication are explained the principles of natural convection; boundary layers and the theory of the coefficient of heat transfer. This work includes a standard of the precise calculation methodology for ventilated roofs which was developed for the purpose of creating a user-friendly guide. The results of individual analyses show, a definitely positive effect of the ventilated cavity on the heat gain reduction of attic rooms. The current technical solution of a roof ridge provides the exhaust of the water vapor from a roof assembly; but for providing ventilation for reducing heat gains is insufficient. This lead to a concept of an innovative roof ridge design which enhances the air exchange between the cavity and outdoor environment.
43

Horský hotel / Mountain hotel

Kyceltová, Lucie January 2014 (has links)
The theme of this work is the building design, brand new mountain hotel with wellness services in Spindleruv Mlyn. The plot is located in a quiet part of town, near a wooded area and form a river Labe.V designed hotel is located three floors above ground level of the building is solved attic space. Roofed by a wooden roof false hip roof. Ground unsophisticated form a geometric shape, which layout is divided into sections. On the ground floor wellness facilities, a portion of the input dopňkovými with hotel services, floor is done mainly for accommodation, as well as the attic. Hotel is equipped with a slightly sloping plot in the construction of houses and other hotels. All living spaces are naturally ventilated and illuminated. The supporting structure consists Liapor system. The appearance of the hotel is in line with the surroundings.
44

Mateřská škola / Kindergarten

Foltas, Petr January 2015 (has links)
The master’s thesis deals with a detailed design documentation of a newly-built kindergarten. The building will be composed of two double-storey objects with a mono-pitched roof and of one single-storey object with a flat green roof. Rooms in the double-storey objects will serve as classes. The kindergarten will contain 4 classes for 100 kids in total. In the single-storey object will be situated rooms meant for operational purposes. All objects will be realised as masonry buildings without a cellar. The design documentation does include hard stadning and hard landscaping.
45

Výstavní galerie v Olomouci / The Exhibition Gallery in Olomouc

Morcinková, Eliška January 2016 (has links)
The aim of this diploma thesis is the design of bearing construction of the Exhibition gallery in Olomouc. The building is of irregular shape with the biggest span of 50 m. The bearing structure in the highest point goes up to 14,6 m. The main design material is the glue-laminated timber GL24h and GL32h. The optimization of chosen parts of the structure has been made and the best option was then used in the detailed structural calculation. The bearing structure consists of circular columns to which the floor beams and roof trusses are connected. The irregular structure of the gallery comprises of three different roof types – flat trafficable roof, double-pitched glass roof formed by pitched cambered trusses and single-pitch roof spanning over the central part of a 20,7 m span. Within the thesis the design and check of the main structure members and connections has been made. The entire structure is pinned and its stiffness is secured by the system of tension rods and rigid floor and roof construction respectively.
46

Nový pavilon SOU Písek / New pavilion SOU Písek

Troup, Tomáš January 2017 (has links)
Diploma thesis deals a project documentation of a new school pavilion SOU in the location Pisek because of the unsatisfactory existing school bulding, which is located at a small distance from the new pavilion. Investor wants to build a new object of universal classrooms for ca. 180 students and sports hall with hygienic and technical facilities, which will be able for football club FC Pisek (football fields and central object of FC Pisek are close to neighboring plots). Investor wants to let the school canteen be on the current place, which is north of the new object. The object is designed as a two-floor with roof ascent (3.NP terrace), part of the building is embedded in the ground. The structural system of the school object is a ceramic bricks system, structural system of the sports hall is a reinforced concrete system. The roof of school object is warm flat roof and roof of sport hall is warm flat roof as well but mono-pitched type. The object has a U -shaped.
47

Horský hotel / Mountain hotel

Moučka, Miroslav January 2022 (has links)
The aim of this master’s project is to develop project documentation of a new-built mountain hotel in Ostružná. This hotel is near the ski area Ramzová in Jeseníky. Foundation of my building is from ground reinforced concrete slab. My building is supported by clay block load-bearing walls and clay non-load bearing walls. Exterior building envelope is designed as an aluminum shingle ventilated facade. The slabs are from reinforced concrete. The roofs of this designed building are two, first is pitched roof with insulation over rafters and second is intensive green warm flat roof. This project contains HVAC concept, photovoltaic panel concept, heating concept in technical equipment of building part. The third part of my master’s project is energy assessment for the building.
48

Veterinární klinika / Veterinary

Šeps, Daniel January 2022 (has links)
The subject of the diploma thesis is the design of a free-standing veterinary clinic building in Nová Paka, in the form of project documentation for the construction. The building of the veterinary clinic consists of 3 rectangles forming a Z-shape, where the entrance to the building of the veterinary clinic, its operational and administrative part is located in the eastern part. In the western rectangle there is a separate and operationally separate entrance to the apartment unit, which is located on the second floor. The entrance to the veterinary clinic building and the housing unit is barrier-free. The building will be located in a slightly sloping terrain (3.49%). The main facade of the building with the entrance to the building is oriented to the southwest. The separate entrance to the apartment unit is from the northeast side. The perimeter masonry consists of the Porotherm system with the ETICS contact thermal insulation system in a thickness of 300 mm and 200 mm ETICS masonry. The internal load-bearing masonry also consists of a Porotoherm masonry system in a thickness of 250 mm. Internal non-load-bearing masonry consisting of the Porotherm system in thicknesses of 115 and 140 mm. The ceiling structure consists of a reinforced concrete slab th. 200 mm. Above the veterinary clinic, the roof area forming the terrace of the housing unit is considered, divided into two parts 1) with a vegetation layer and 2) with a tread layer of concrete paving on the targets. The main waterproofing layer of the flat roof consists of strips of SBS modified asphalt. Above the 2nd floor, a sloping hip roof made of glued wooden trusses is considered, and a sheet metal roofing is considered as the roof covering of the truss roof. The windows are designed with insulating triple glazing. The attic on the flat roof is equipped with an aluminum railing with a vertical bar infill. The building is heated by a gas condensing boiler, the building is also designed forced ventilation
49

Horský hotel / Mountain hotel

Vandrovec, Aleš January 2014 (has links)
Master’s thesis theme is mountain hotel project. The hotel has one lower basement and four aboveground floor. It has trditional look and the roof is double-pitched. Floor projection looks like letter "L". Main part has measurements 25,3 x 14,1 m and it has four floor. Extension is on northwest side of main part. It has measuremnts 11,85 x 9,5 m and three floor. Facede of basement and first floor is from stone facing mansory. Facade od second floor of main patr of buildings id timbered looks like curb. Third and fourth floor are attic, gable is vertical timbered. Facade of second floor of extension is plaster on ETICS. The gable od extension is vertical timbered. Roof covering is alpen shingle from larch wood. Foundations of house are shallow. The construction system is walled. The lower basement is built from masonry BS Klatovy BD30 and other wall are from masonry Porotherm . Floor structures are from monolithic reinforced concrete, thickness 220 mm. House stairs are prefabricated double-flight. Partition wall are mostly built from mansory Porotherm 11,5 P+D. Lintols above windows and doors in facadeare made by reverse of floor slab and inside of disposition are made by ceramics lintols Porotherm. Floor structures are floating with impact insulation in whole house. In living rooms wear layers are from oak parquet block and in common rooms, toilets, bathrooms and technical rooms is ceramics paving. Wall’s surfaces are made from patent plaster and in lower basement are made from two-coat work with white coat. Toilets and bathrooms are tilled with ceramic tiles. All distributions of building equipment are covered with gypsum plasterboard ceiling. All windows and doors in facade are made by wooden profile Solid comfort SC78 and glazed by triple glazing unit (Uw,max=0,9 W/m2.K), exception is main entrance door, It is made by aluminum profile and it is automatically opened.
50

Penzion pro seniory / Senior house

Voráč, Roman January 2016 (has links)
Content of this thesis is proces and structural layout design of subject „SENIORS’ BOARDINGHOUSE“. It’s a wide subject, which south wing is designed as single-storey with cellarage, central subject is two-storeyd without cellarage. Wooden shelters are connected to north and south wing. Architecture has been chosen in order to make a subject evoking calm and positive impression for retirement aged persons living. Roof structure is double-pitched shape with two main skylights. Roof is red coloured and a facade is white. Interior space of subject is designed to satisfy a demands for comfortable living of single persons (one-room flats) as well as retirement aged couples (2+KK flats). Round the subject there are situated further tinier subjects there designed for utilization by seniors, but for those who are still active. Subject is brick, founded on continuous footing and spreading slab. Roof structure is constructed of wooden bearing rafter framework which is, in case of main object, designed with central binding rafter and collar roof in case of north and south wing. Subject is insulated with External Thermal Insulation Composite System, roof is covered by ceramic roof covering in combination with folded sheet metal covering. Main living quarters is situated in first and second above-ground storey of central subject, restaurant with background lie in south wing and wellness available for public as well is situated in north wing. In basement of south wing there is technical background of whole subject situated there as is garage, technical room, service room, bicycle room and storage. Next the kitchen staff background including storages for kitchen lie here.

Page generated in 0.0494 seconds