A Fixed-scale Pixelated MIMO Visible Light Communication System

Han, Boxiao January 2017 (has links)
Visible light communication (VLC) systems take advantage of ubiquitous light-emitting diodes (LED) and leverage existing illumination infrastructure to provide broadband optical communication links. Multiple-input multiple-output (MIMO) VLC systems are among the well studied topics in VLC research. However, most traditional MIMO VLC systems require accurate alignment and have to adjust to different magnifications at various link distances. Consequently, the alignment and calibration modules increase the complexity of the receiver structures. A pixelated MIMO VLC system is introduced in this thesis, which transmits a series of time-varying coded images that can be received and decoded by commercial digital cameras. Using a convex lens placed in front of the transmitter at its focal length, the system exploits the Bokeh effect to obtain fixed-scale images at all link distances. Compared with traditional pixelated MIMO VLC systems, which send information directly in space, this spatial-angular mapping system sends information in different angles instead. In contrast to the complex receiver structures in traditional setups, the proposed system can capture fixed-scale images with a simple receiver requiring no re-focusing as the camera moves. The channel model of the system is measured and modeled and a rateless code is applied to track the truncation of receive images for various link ranges and angular offsets. A proof-of-concept optical communication system is implemented with an LCD display and a high speed CMOS camera. Performance of the system is measured and analysed. The experimental system can achieve a throughput of approximately 10 bit per frame over 90 cm. This fixed-scale pixelated MIMO wireless optical communication system provides a less expensive option for short-range indoor broadcasting optical links and inter-vehicle communications due to its mobility, stability and simpler receiver structure compared to traditional designs in different working conditions. / Thesis / Master of Applied Science (MASc)
2

Nouveaux composants optiques pixellisés pour la correction visuelle : modélisation, optimisation et évaluation / New pixelated optical components for visual correction : modelling, optimization and evaluation

Peloux, Marius 12 October 2011 (has links)
Ce manuscrit de thèse traite de l’étude de verres ophtalmiques microstructurés et plus particulièrement pixellisés, ces derniers pouvant présenter un intérêt particulier en optique active pour la correction de la presbytie. Une étude théorique est proposée, permettant d’analyser les performances optiques d’une lentille pixellisée en termes de transport d’image et d’identifier les paramètres qui ont un impact direct sur ces performances. Après validation expérimentale des résultats obtenus, nous constatons puis expliquons l’effet sur l’observation d’une scène de l’excentrement de l’œil par rapport à la fonction de phase du verre. Nous étudions l’effet du repliement de phase inhérent aux limites des technologies de fabrication, qui vient ajouter un chromatisme axial aux défauts visuels engendrés par la pixellisation. Nous nous intéressons ensuite aux applications possibles de la pixellisation en optique passive. Nous prouvons que pour une application visée, des lentilles binaires non pixellisées, dont nous optimisons la qualité optique, conduisent à de meilleurs résultats que les lentilles pixellisées. L’impact sur l’acuité visuelle des phénomènes diffractifs parasites induits par la pixellisation est évalué au moyen d’un banc de mesure utilisant la simulation de certaines images telles qu’elles seraient vues au travers de verres ophtalmiques pixellisés. Enfin, nous menons une étude de l’aspect esthétique d’un verre pixellisé vu par un observateur externe, à partir de modèles de calcul hybrides mêlant optique géométrique et optique de Fourier. / This thesis investigates microstructured and more particularly pixelated ophthalmic glasses, the latter raising some hope for the active correction of presbyopia. A theoretical study is developed for the analysis of the optical performances of a pixelated lens in terms of image transport and leads to the identification of the parameters which have an impact on these performances. After experimental validation of the results obtained, we note and then explain the effect on the observation of a scene of eye displacement with respect to the optical function of the eyeglass. We study the effect of phase wrapping, which is inherent in the limits of the technologies implied in the manufacturing process and adds an axial chromatism effect to the visual defects generated by pixelation. We are also interested in the potential applications of pixelation in the field of passive optics. We prove that for a given application, non pixelated binary lenses, the optical quality of which we optimize, lead to better results than pixelated lenses. The impact on visual acuity of the parasitic diffractive phenomena induced by pixelation is evaluated with an optical bench using the simulation of test images seen through pixelated lenses. Finally, we study the aesthetic aspect of a pixelated component as seen by an external observer, using hybrid calculation models based on both geometrical and Fourier optics.
3

Elaboration et caractérisation de matériaux hybrides organiques - inorganiques : application à l’optique ophtalmique / Preparation and characterization of hybrid organic - inorganic materials : application to ophthalmic optics

Courson, Rémi 22 April 2011 (has links)
Cette thèse s'inscrit dans le projet optique digital porté par la société Essilor, leader mondial dans le domaine de l'optique ophtalmique. La collaboration entre le laboratoire Charles Coulomb et Essilor a donné naissance à une nouvelle génération de systèmes optiques apposés directement sur le verre ophtalmique. Ce système est constitué de microcuves remplies d'un autre matériau pouvant être différent d'une cuve à l'autre. Il en résulte une pixellisation de la surface permettant des phénomènes optiques innovants. La première partie de ce travail est consacrée à la synthèse et à la caractérisation de résines hybrides organiques-inorganiques photosensibles fonctionnant à différentes longueurs d'ondes. Le but est de créer les microcuves par un procédé de photolithographie dont la rigidité est telle que les murs puissent résister au remplissage par un liquide. Les polymérisations minérales et organiques de ces résines ont été étudiées d'un point de vue structural (spectroscopie infrarouge et RMN), mécanique (technique de nanoindentation) et texturale (absorption - désorption de gaz). La deuxième partie porte sur l'incorporation d'une couche ultraporeuse à l'intérieur des microcuves. Le choix final s'est porté sur un aérogel de silice mélangé à un polymère et réalisé par séchage en condition supercritique du CO2. Ses propriétés sont caractérisées par diverses techniques comme le MEB, les spectroscopies infrarouge et UV-Visible, la microscopie AFM et la nanoindentation. Ce système constitué de microcuves remplies d'un matériau ultraporeux peut alors être imprégné localement par différents liquides d'indice de réfraction variés afin d'obtenir les effets optiques désirés. / This thesis is feeling part of the optical digital project carried out by Essilor, the world leader in the ophthalmic optics field. The collaboration between the Charles Coulomb Laboratory (LCC) and Essilor has spawned a new generation of optical systems affixed directly on the ophthalmic glass. This system consists of microtanks filled with material that may be different from one tank to the other. The result is a pixelated surface which can be lead to innovative optical phenomena. The first part of this work is devoted to the synthesis and characterization of photosensitive organic-inorganic hybrid resins operating at different wavelengths. The goal is to create by a photolithography process microtanks whose rigidity is such that the walls can resist with a liquid filling. Polymerizations of hybrid photosensitive resins have been studied in a structural (infrared and NMR spectroscopy), mechanical (nanoindentation technique) and textural (absorption - desorption of gas) way. The second part focuses on the ultraporous layer incorporation inside microtanks. The final choice fell on silica aerogel containing polymer and obtained under CO2 supercritical drying conditions. Its properties are characterized by various techniques such as SEM, infrared and UV-Visible spectroscopy, AFM microscopy and nanoindentation technique. The all system consists of microtanks filled with an ultraporous material which can be locally impregnated by different liquids with a varied refractive index to obtain the desired optical effects.
4

Úprava obrazu a zvuku ve zpravodajství s cílem znesnadnění identifikace osob (na příkladu hlavních zpravodajských relací České televize, TV Nova a FTV Prima) / Adjusting the television picture and sound in newscast to make it more difficult to identify people (newscast of Česká televize, TV Nova and FTV Prima)

Sváček, Martin January 2016 (has links)
The Diploma Thesis deals - within its theoretical part - with situations in TV news, which require conversion of audiovisual content to achieve involved person's anonymity. Ethics codes of analysed television stations are major factor in this part, also included as secondary support relavant studies, reference books, laws and edicts. Conversion of audiovisual content is necessary - speaking of victims of crime (mainly violent or sexual offense) and theirs relatives, children, suspects and theirs relatives, anonymous sources, some criminalists or other vulnerable persons. Practical part of the thesis applies gained informations to analyse audio-visual recordings - broadcasted by Czech TV (Česká televize), TV Nova and FTV Prima. Study reflected diffrences between conversion of same situations and same persons. Study also reflected some ethically controversial moments. Several reporters gived an interview to comment selected news.
5

Implémentation de la répartition de charge et du mode TOT pour la simulation d’un détecteur Timepix à pixels

Dallaire, Frédérick 03 1900 (has links)
Les détecteurs à pixels Medipix ont été développés par la collaboration Medipix et permettent de faire de l'imagerie en temps réel. Leur surface active de près de $2\cm^2$ est divisée en 65536~pixels de $55\times 55\um^2$ chacun. Seize de ces détecteurs, les Medipix2, sont installés dans l'expérience ATLAS au CERN afin de mesurer en temps réel les champs de radiation produits par les collisions de hadrons au LHC. Ils seront prochainement remplacés par des Timepix, la plus récente version de ces détecteurs, qui permettent de mesurer directement l'énergie déposée dans chaque pixel en mode \textit{time-over-threshold} (TOT) lors du passage d'une particule dans le semi-conducteur. En vue d'améliorer l'analyse des données recueillies avec ces détecteurs Timepix dans ATLAS, un projet de simulation Geant4 a été amorcé par John Id\'rraga à l'Université de Montréal. Dans le cadre de l'expérience ATLAS, cette simulation pourra être utilisée conjointement avec Athena, le programme d'analyse d'ATLAS, et la simulation complète du détecteur ATLAS. Sous l'effet de leur propre répulsion, les porteurs de charge créés dans le semi-conducteur sont diffusés vers les pixels adjacents causant un dépôt d'énergie dans plusieurs pixels sous l'effet du partage de charges. Un modèle effectif de cette diffusion latérale a été développé pour reproduire ce phénomène sans résoudre d'équation différentielle de transport de charge. Ce modèle, ainsi que le mode TOT du Timepix, qui permet de mesurer l'énergie déposée dans le détecteur, ont été inclus dans la simulation afin de reproduire adéquatement les traces laissées par les particules dans le semi-conducteur. On a d'abord étalonné le détecteur pixel par pixel à l'aide d'une source de $\Am$ et de $\Ba$. Ensuite, on a validé la simulation à l'aide de mesures d'interactions de protons et de particules $\alpha$ produits au générateur Tandem van de Graaff du Laboratoire René-J.-A.-Lévesque de l'Université de Montréal. / The pixelated Medipix detectors have been developed by the Medipix Collaboration to perform real-time imaging. The semiconducting chip is divided into 65536 pixels of $55\times 55\um^2$ for a total active area of nearly $2\cm^2$. Because of their sensitivity to all kinds of particles, sixteen Medipix2 detectors (ATLAS-MPX) have been placed in the ATLAS detector and its cavern to measure for the radiation produced by the head-on proton collisions produced at the LHC. At the next ATLAS upgrade, the ATLAS-MPX network will be extended to include the Timepix detectors, the latest version that allows one to measure the total energy deposited in the semiconductor. To improve data analysis, a Geant4 simulation project of a Timepix detector was initiated by John Id\'arraga at the Université de Montréal. In the framework of the ATLAS experiment, this simulation could be used with Athena, the ATLAS analysis software, and the full ATLAS simulation. Due to their repulsivity, the charge carriers created by an incoming particle in the pixelated detector are spread over the surrounding pixels causing a charge sharing effect. An effective model has been developed to reproduce this effect without resolving the charge drift's differential equation. This model and the \textit{time-over-threshold} mode of the Timepix have been included in the simulation to reproduce the tracks left by the striking particles. First, one had to individually calibrate each pixel of the device with $\Am$ and $\Ba$ sources. The simulation's validation has been performed with low energy protons and $\alpha$ particles delivered by the van de Graaff Tandem at the Laboratoire René-J.-A.-Lévesque of the Université de Montréal.
6

Implémentation de la répartition de charge et du mode TOT pour la simulation d’un détecteur Timepix à pixels

Dallaire, Frédérick 03 1900 (has links)
Les détecteurs à pixels Medipix ont été développés par la collaboration Medipix et permettent de faire de l'imagerie en temps réel. Leur surface active de près de $2\cm^2$ est divisée en 65536~pixels de $55\times 55\um^2$ chacun. Seize de ces détecteurs, les Medipix2, sont installés dans l'expérience ATLAS au CERN afin de mesurer en temps réel les champs de radiation produits par les collisions de hadrons au LHC. Ils seront prochainement remplacés par des Timepix, la plus récente version de ces détecteurs, qui permettent de mesurer directement l'énergie déposée dans chaque pixel en mode \textit{time-over-threshold} (TOT) lors du passage d'une particule dans le semi-conducteur. En vue d'améliorer l'analyse des données recueillies avec ces détecteurs Timepix dans ATLAS, un projet de simulation Geant4 a été amorcé par John Id\'rraga à l'Université de Montréal. Dans le cadre de l'expérience ATLAS, cette simulation pourra être utilisée conjointement avec Athena, le programme d'analyse d'ATLAS, et la simulation complète du détecteur ATLAS. Sous l'effet de leur propre répulsion, les porteurs de charge créés dans le semi-conducteur sont diffusés vers les pixels adjacents causant un dépôt d'énergie dans plusieurs pixels sous l'effet du partage de charges. Un modèle effectif de cette diffusion latérale a été développé pour reproduire ce phénomène sans résoudre d'équation différentielle de transport de charge. Ce modèle, ainsi que le mode TOT du Timepix, qui permet de mesurer l'énergie déposée dans le détecteur, ont été inclus dans la simulation afin de reproduire adéquatement les traces laissées par les particules dans le semi-conducteur. On a d'abord étalonné le détecteur pixel par pixel à l'aide d'une source de $\Am$ et de $\Ba$. Ensuite, on a validé la simulation à l'aide de mesures d'interactions de protons et de particules $\alpha$ produits au générateur Tandem van de Graaff du Laboratoire René-J.-A.-Lévesque de l'Université de Montréal. / The pixelated Medipix detectors have been developed by the Medipix Collaboration to perform real-time imaging. The semiconducting chip is divided into 65536 pixels of $55\times 55\um^2$ for a total active area of nearly $2\cm^2$. Because of their sensitivity to all kinds of particles, sixteen Medipix2 detectors (ATLAS-MPX) have been placed in the ATLAS detector and its cavern to measure for the radiation produced by the head-on proton collisions produced at the LHC. At the next ATLAS upgrade, the ATLAS-MPX network will be extended to include the Timepix detectors, the latest version that allows one to measure the total energy deposited in the semiconductor. To improve data analysis, a Geant4 simulation project of a Timepix detector was initiated by John Id\'arraga at the Université de Montréal. In the framework of the ATLAS experiment, this simulation could be used with Athena, the ATLAS analysis software, and the full ATLAS simulation. Due to their repulsivity, the charge carriers created by an incoming particle in the pixelated detector are spread over the surrounding pixels causing a charge sharing effect. An effective model has been developed to reproduce this effect without resolving the charge drift's differential equation. This model and the \textit{time-over-threshold} mode of the Timepix have been included in the simulation to reproduce the tracks left by the striking particles. First, one had to individually calibrate each pixel of the device with $\Am$ and $\Ba$ sources. The simulation's validation has been performed with low energy protons and $\alpha$ particles delivered by the van de Graaff Tandem at the Laboratoire René-J.-A.-Lévesque of the Université de Montréal.
7

Assurance qualité des traitements par hadronthérapie carbone par imagerie de particules promptes chargées / Quality assurance for carbon hadrontherapy treatments with prompt charged particles imaging

Reithinger, Valérian 29 September 2015 (has links)
L'hadronthérapie est une modalité de radiothérapie innovante dans laquelle des ions légers -tels des protons ou des ions carbone- sont accélérés à une vitesse relativiste, puis focalisés afin d'irradier la zone tumorale du patient. Cette technique se démarque de la radiothérapie dite conventionnelle utilisant des photons- par l'existence d'un pic de dépôt d'énergie, appelé pic de Bragg, qui se situe à la fin du parcours des ions. L'existence de différents phénomènes qui aboutissent à une incertitude sur le parcours des ions représente toutefois une limite à la précision intrinsèque de cette modalité. Cela justifie la nécessité d'une assurance qualité des traitements et motive le développement de techniques de suivi en ligne et en temps réel du parcours des ions. Ces travaux de thèse ont pour objet la caractérisation d'une technique de suivi du parcours des ions, appelée imagerie des vertex d'interaction. Il a en effet été observé que lors du parcours des ions dans le patient, une fraction importante de ceux-ci subit des réactions nucléaires, à l'origine d'un rayonnement de particules promptes secondaires chargées. Un télescope constitué de capteurs pixélisés est proposé pour localiser les vertex d'interaction de ces particules et mesurer leur corrélation avec le parcours des ions, corrélation prédite par des travaux in-silico précédents. La réalisation de plusieurs expériences durant lesquelles des cibles homogènes et hétérogènes ont été irradiées dans des conditions réalistes a permis d'obtenir les premiers résultats expérimentaux relatifs à cette technique, confrontés à des simulations qui ont également été réalisées. Avant de discuter l'ensemble des résultats obtenus, ce manuscrit détaille les aspects matériels et logiciels des importants développements mis en oeuvre et qui ont abouti à un prototype complet et fonctionnel d'imageur, accompagné de simulations Monte Carlo basées sur le logiciel Geant4 / Hadrontherapy is an innovative radiotherapy modality in which light ions -such as protons or carbon ionsare accelerated to a relativistic speed and focused to irradiate a tumoral area. This technique differs from the conventional radiotherapy -which uses photons- by the existence of an energy deposition peak, called Bragg peak, which stands at the end of the ions path. However, different phenomena that lead to uncertainty in the real ion range exist, and limit the intrinsic accuracy of this modality. This justifies the need for a treatments quality assurance and motivates the development of in-line and real-time monitoring techniques to follow the real ions range. This PhD thesis work aims the characterization of an ion range monitoring technic, called interaction vertex imaging. It has been observed that during the ion path in the patient, a significant part of incoming ions undergoes nuclear reactions, causing a prompt secondary charged particles radiation. A telescope made up of pixelated sensors is proposed to locate these particles interaction vertex and to measure their correlation with the ions range, correlation predicted by a previous in-silico work. The first experimental results for this technique has been obtained with the realization of several experiments during which homogeneous and heterogeneous targets were irradiated under realistic conditions. Simulations were also performed to compare with experimental results. Before discussing the overall results, this manuscript details the hardware and software aspects of important developments that was made and that resulted in a complete and working prototype imager, with Monte Carlo simulations based on the Geant4 software
8

Quantitative Imaging in Scanning Electron Microscope / Quantitative Imaging in Scanning Electron Microscope

Skoupý, Radim January 2020 (has links)
Tato práce se zabývá možnostmi kvantitativního zobrazování ve skenovacím (transmisním) elektronovém mikroskopu (S|T|EM) společně s jejich korelativní aplikací. Práce začíná popisem metody kvantitativního STEM (qSTEM), kde lze stanovenou lokální tloušťku vzorku dát do spojitosti s ozářenou dávkou, a vytvořit tak studii úbytku hmoty. Tato metoda byla použita při studiu ultratenkých řezů zalévací epoxidové pryskyřice za různých podmínek (stáří, teplota, kontrastování, čištění pomocí plazmy, pokrytí uhlíkem, proud ve svazku). V rámci této části jsou diskutovány a demonstrovány možnosti kalibračního procesu detektoru, nezbytné pozadí Monte Carlo simulací elektronového rozptylu a dosažitelná přesnost metody. Metoda je pak rozšířena pro použití detektoru zpětně odražených elektronů (BSE), kde byla postulována, vyvinuta a testována nová kalibrační technika založená na odrazu primárního svazku na elektronovém zrcadle. Testovací vzorky byly různě tenké vrstvy v tloušťkách mezi 1 až 25 nm. Použití detektoru BSE přináší možnost měřit tloušťku nejen elektronově průhledných vzorků jako v případě qSTEM, ale také tenkých vrstev na substrátech - qBSE. Obě výše uvedené metody (qSTEM a qBSE) jsou založeny na intenzitě zaznamenaného obrazu, a to přináší komplikaci, protože vyžadují správnou kalibraci detektoru, kde jen malý posun úrovně základního signálu způsobí významnou změnu výsledků. Tato nedostatečnost byla překonána v případě qSTEM použitím nejpravděpodobnějšího úhlu rozptylu (zachyceného pixelovaným STEM detektorem), namísto integrální intenzity obrazu zachycené prstencovým segmentem detektoru STEM. Výhodou této metody je její použitelnost i na data, která nebyla předem zamýšlena pro využití qSTEM, protože pro aplikaci metody nejsou potřeba žádné zvláštní předchozí kroky. Nevýhodou je omezený rozsah detekovatelných tlouštěk vzorku způsobený absencí píku v závislosti signálu na úhlu rozptylu. Obecně platí, že oblast s malou tloušťkou je neměřitelná stejně tak jako tloušťka příliš silná (použitelný rozsah je pro latex 185 - 1 000 nm; rozsah je daný geometrií detekce a velikostí pixelů). Navíc jsou v práci prezentovány korelativní aplikace konvenčních a komerčně dostupných kvantitativních technik katodoluminiscence (CL) a rentgenové energiově disperzní spektroskopie (EDX) spolu s vysokorozlišovacími obrazy vytvořenými pomocí sekundárních a prošlých elektronů.