Particle-In-Cell Method To Predict Plasma Behavior Between Two PlatesTsai, Jie-Cheng 09 August 2011 (has links)
This study uses the PIC (particle-in-cell) method to simulate unsteady three-dimensional behavior in argon plasma under low pressure , low density between two plates. Plasma has been widely used in materials processing, film manufacturing, nuclear fusion , light source , etc. It is therefore important to study Plasma behavior . This model ignores secondary electron emission , recombination between ions and electrons and assumes a uniform distribution of the neutrals having velocity of a Maxwellian distribution. The lower plate in subject to a biased voltage and magnetic field. The result show the effects of a biased voltage in density and velocity of the ion and electron with the low plate.
|