• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1606
  • 25
  • 16
  • 3
  • 1
  • Tagged with
  • 1673
  • 1015
  • 638
  • 504
  • 450
  • 434
  • 343
  • 338
  • 314
  • 279
  • 261
  • 203
  • 202
  • 188
  • 183
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Influência dos parâmetros de usinagem na qualidade da microfuração com laser pulsado Nd:YAG em chapas de aço inoxidável AISI 316L / Influence of machining parameters in quality of microdrilling with Nd: yag pulsed laser in stainless steel plates aisi 316L

Salgado Junior, Dair Ferreira [UNESP] 12 December 2016 (has links)
Submitted by DAIR FERREIRA SALGADO JUNIOR null (dairsalgado@gmail.com) on 2017-01-05T17:54:35Z No. of bitstreams: 1 Dissertação.pdf: 5078960 bytes, checksum: f66841a9969c704bd527a1761f8e7e3b (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-01-10T17:08:35Z (GMT) No. of bitstreams: 1 salgadojunior_df_me_ilha.pdf: 5078960 bytes, checksum: f66841a9969c704bd527a1761f8e7e3b (MD5) / Made available in DSpace on 2017-01-10T17:08:35Z (GMT). No. of bitstreams: 1 salgadojunior_df_me_ilha.pdf: 5078960 bytes, checksum: f66841a9969c704bd527a1761f8e7e3b (MD5) Previous issue date: 2016-12-12 / A evolução do processo de furação nos trouxe ao desenvolvimento do método de furação por laser pulsado, mas não temos definido o que a variação de cada parâmetro produz nos microfuros em relação à qualidade dos mesmos medidos com base em seu formato em aço inoxidável austenítico AISI 316L. O presente estudo analisou como variações na potência de pico, largura temporal do pulso e existência ou não de atmosfera protetora podem mudar os tamanhos, formatos e profundidades em microfuros. Produziram-se combinações dos parâmetros que foram usadas para obter furos em chapas de aço AISI 316L com 1 mm de espessura com o uso de uma fonte de laser pulsado Nd:YAG e analisar as propriedades em cada combinação, tais como diâmetros de entrada e de saída, profundidades e formatos observados em estereoscópio.
262

Estudo do conversor zeta em condução simultânea dos semicondutores aplicada à alimentação de LEDs de potência

Pedrollo, Guilherme Rodrigues January 2015 (has links)
Made available in DSpace on 2015-06-18T02:05:31Z (GMT). No. of bitstreams: 1 000470517-Texto+Completo-0.pdf: 3643142 bytes, checksum: 1f5335f433b80cbcbe58f559422c4f72 (MD5) Previous issue date: 2015 / This work presents the simultaneous conduction mode (SCM), which is applied to the operation of the Zeta converter. This mode has the ability to implement an ideal power factor corrector (PFC) employing only one feedback control loop. In SCM, the current in the main switch and in the diode flows simultaneously within one of the operation stages. In SCM, the power converter presents characteristics of both conduction modes: continuous conduction mode (CCM) and discontinuous conduction mode (DCM). In SCM, the currents in the inductors of the power converter are never nullified, which is a typical behavior of the CCM. Nevertheless, the SCM does that while obtaining an ideal PFC with just one control loop. The SCM maintains its features, regardless of its control variable being the output current or the output voltage of the power converter. The solely application of a fixed duty cycle controller is enough to attain all these advantages, which is usually a feature of the DCM for PFCs of the flyback family. In order to validate the proposed technique, a complete study of the Zeta converter working in this new operation mode was performed. This study has included a qualitative and a quantitative power converter analysis. These analyses resulted in the development of a design methodology for the Zeta power converter working as a PFC in the SCM. In order to validate the present study, a prototype of the Zeta PFC for operation in the SCM was designed and built. This prototype was developed, as a case of study, to drive a power LED lamp (180°W). Thus, it was obtained the desired experimental confirmation for the research. The main advantage of the SCM, in comparison to the CCM, lies in its ability to maintain the input current of the PFC sinusoidal and in phase with the input voltage, which is imposed by the mains through the use of just a single PWM controller with fixed duty cycle. These results have, also, shown that the current peaks in the main semiconductors of the power converter are lower than their respective values in the DCM. However, this new operation mode results in the increase of the voltages on the main switch and diode in relation to the conventional power converter operation. The research of the application of the proposed method to other power converters is suggested to further works. / Este trabalho propõe a operação do conversor Zeta no modo de condução simultânea (MCS), cujo interesse reside na capacidade de implementação de um pré-regulador do fator de potência (PFP) ideal empregando apenas um laço de realimentação. Quando o conversor trabalha no MCS, a chave principal e o diodo conduzem simultaneamente em um de seus estágios de operação. Neste modo de condução, o conversor estático apresenta características de ambos os modos de condução conhecidos até agora: o modo de condução contínua (MCC) e o modo de condução descontínua (MCD). A operação no MCS resulta em um conversor estático operando como se estivesse no MCC, uma vez que a corrente nos indutores nunca se anula. Embora mantenha o conversor estático trabalhando com esta característica do MCC, o MCS permite a obtenção de um comportamento quase ideal do PFP, utilizando apenas um único controlador, seja ele de corrente ou de tensão, o qual mantém a razão cíclica do conversor constante, assim como usualmente ocorre com os PFPs da família redutor-elevador quando operam no MCD. Visando validar esta técnica, foi realizado um estudo do conversor operando desta forma que incluiu o desenvolvimento das análises qualitativa e quantitativa do conversor, as quais culminaram na elaboração de uma metodologia de projeto. Assim, realizou-se o projeto de um PFP, baseado no conversor Zeta, para energizar uma luminária LED de 180 W, operando no MCS, como estudo de caso. A luminária utilizada é o modelo High Power LED Baylight da empresa Luckysunny®. Os resultados obtidos experimentalmente validaram a estratégia proposta, uma vez que, com a operação do conversor Zeta no MCS reduz-se a ondulação (ripple) da corrente nos semicondutores em relação à operação no MCD. A principal vantagem da operação no MCS reside no fato deste manter a corrente de entrada do PFP senoidal em fase com a tensão imposta pela rede elétrica com apenas uma malha de controle da variável de saída de interesse seja ela tensão ou corrente como no estudo de caso em questão. Isto reduz o custo e a complexidade do controlador do conversor. Entretanto, esta estratégia apresenta sobretensão na chave principal e no diodo como principal desvantagem. Sugere-se a investigação da aplicação da metodologia de projeto proposta a outros conversores.
263

Pedagogia poiética para a potência humana: o reconhecimento, a nutrição e a expansão da potência humana das comunidades aprendentes, em processos poiéticos colaborativos de reorientação curricular pedagógica cultural, e as tecituras transdisciplinares das alfabetizações de mundos em rodas de conversações

Trindade, Ana Felícia Guedes January 2015 (has links)
Made available in DSpace on 2015-11-28T01:04:47Z (GMT). No. of bitstreams: 1 000476495-Texto+Completo-0.pdf: 15935701 bytes, checksum: 2d78dd465fb5986d7af4bdbd764c181e (MD5) Previous issue date: 2015 / This thesis defends human potency. From the potency of human nature to humanities in its potent movements. The potency defended in this study is recognized from complex organicbiological- cultural reorganizations produced in movements of autopoiesis(Maturana,1979) which are weaved mainly in historical and social, philosophical and anthropological, psychological and aesthetic circumstances, which are forged in the multiple dimensions of a human being's life and are entwined and developed, nurtured both by autopoietic and by bioanthro- poetic processes (Morin,1990). From this complex production, human beings exercise the organization and the disorganization of identities and authorships in which autonomy, as life production (Freire, 1979) is generated and gestated. This deeply complex and autopoietic production, which constitutes the being, nurtures human potency, which expands and strenghtens in human processes. The present thought, produced by approaching these three authors from distinct scientific schools and complemented by other authors in the realm of human and social sciences, constitutes the theoretical-practical basis for the research conducted at Escola Municipal de Ensino Fundamental Erna Würth, Canoas/RS, a participative and collaborative action-research called "Poietic Pedagogy for Human Potency".The research is a proposal of exercises of teaching potency, in conversation circles as continuing education, in a productive workfield, considering the nurturing and the viewing of learning and teaching processes, by recognizing students' potencies. The conversation circles generate, through meditated conversations, the Letter of Principles, the Worlds Literacies, the Webs of Life and the Orienting Threads – collaborative pedagogical-poietical webbings which constitute today the pedagogical-cultural planning construction of the learning community. / Esse trabalho defende a Potência Humana. Desde a potência da natureza humana às humanidades em seus movimentos potentes. A Potência defendida nesse estudo é reconhecida das complexas reorganizações orgânicas-biológicas-culturais produzidas em movimentos de Autopoiese (Maturana, 1979), que se tecem, principalmente, em circunstâncias históricas e sociais, filosóficas e antropológicas, psíquicas e estéticas, as quais forjam-se nas múltiplas dimensões da vida do ser humano, e tramam-se e desenvolvem-se, nutridos por processos autopoiéticos, assim como em processos Bioantropoéticos (Morin,1990). Dessa produção complexa, o ser humano produz exercícios organizadores e desorganizadores de identidades e autorias, em que a Autonomia, como produção de vida (Freire, 1979), gera-se e gesta-se. Essa produção, profundamente complexa e autopoiética, constituidora do ser, nutre sua Potência Humana, que expande-se, fortalecendo-o em seus processos humanos. O pensamento presente, produzido pelas aproximações desses três autores de escolas científicas distintas, e complementados por outros autores do campo das ciências humanas e sociais, constitui a base teórico-prática, a qual torna-se a investigação do doutoramento, na Escola Municipal de Ensino Fundamental Erna Würth, Canoas/RS, na perspectiva de uma Pesquisaação Participativa Colaborativa, intitulando-se "Pedagogia Poiética para a Potência Humana". Desenvolve-se como proposta de exercícios da potência docente, em rodas, por meio de Conversações, como formação contínua em campo produtivo de trabalho tendo, em vista, a nutrição e vitalização dos processos de aprendências e ensinâncias, pelo reconhecimento da potência dos estudantes. As Rodas de Conversações gestam, pelas Conversações Reflexionadas, a Carta de Princípios, as Alfabetizações de Mundos, as Teias da Vida e os Fios Orientadores - tecituras colaborativas pedagógicas-poiéticas, que constituem, hoje, o constructo de planejamento pedagógico-cultural da Comunidade Aprendente.
264

Estudo da modelagem dinâmica de pequenos sinais do conversor ZETA no MCD alimentado a partir de painéis fotovoltaicos para conexão à rede elétrica

Viero, Renan Caron January 2011 (has links)
Made available in DSpace on 2013-08-07T18:52:57Z (GMT). No. of bitstreams: 1 000434645-Texto+Completo-0.pdf: 2873661 bytes, checksum: 6694c7a444c8a14c7c6a3a5f6dbc2b1f (MD5) Previous issue date: 2011 / This work presents the study and development of the small-signal dynamic modeling of the ZETA converter operating in discontinuous conduction mode, powered from photovoltaic solar panels in order to connect them to the power grid. Initially, it is presented a study of the main characteristics of solar cells. A deep analysis of the ZETA converter working in steady state is performed, considering that the Zeta converter synthesizes a rectified sine wave current with the same frequency as the power grid. This feature makes this converter a key part in implementing the module integrated inverter for photovoltaic systems. The converter is analyzed in the switching frequency and in the power grid frequency. A detailed examination of the dynamic behavior of the Zeta converter is achieved by the state-space averaging modeling approach, resulting in a linear analytical model described in state variables. In all tests it was assumed that the commercial power grid presents a resistive load behavior (variable value). Finally, the analytical dynamic model obtained is validated through computer simulations and by laboratory tests on a prototype specially designed for this purpose. / Este trabalho apresenta o estudo e o desenvolvimento da modelagem dinâmica de pequenos do conversor ZETA operando no modo de condução descontínuo, alimentado a partir de painéis solares fotovoltaicos, para conexão à rede elétrica. Inicialmente, é apresentado um estudo das principais características das células solares. Uma análise profunda sobre o conversor ZETA operando em regime permanente é realizada, considerando que o mesmo sintetiza uma onda senoidal retificada de baixa freqüência. O conversor é analisado tanto na freqüência de comutação como na freqüência da rede elétrica. Esta característica transforma este conversor em uma peça fundamental na implementação do inversor módulo integrado para sistemas fotovoltaicos. Um exame detalhado do comportamento dinâmico do conversor é realizado através da abordagem do modelo médio no espaço de estados, resultando em um modelo linear analítico descrito em variáveis de estado. Em todas as análises se assume a rede elétrica comercial como uma carga com comportamento resistivo (variável). Por fim, o modelo dinâmico analítico obtido é validado através de simulações computacionais e através de ensaios laboratoriais em um protótipo especialmente elaborado para este fim.
265

Inversor módulo integrado utilizando um conversor CC-CC Zeta com controle MPPT FeedForward

Lopez, Henrique Fioravanti Miguel January 2009 (has links)
Made available in DSpace on 2013-08-07T18:53:44Z (GMT). No. of bitstreams: 1 000418751-Texto+Completo-0.pdf: 6725279 bytes, checksum: e5d1c8ffd25a23f7c4192f021029d702 (MD5) Previous issue date: 2009 / This work presents the study and development of a processing power system that could be used in the connection of renewable energy sources to commercial power grid. The system consists of a ZETA converter associated with a bridge inverter operating at low frequency. The Zeta converter, operating in discontinuous conduction mode (DCM), plays the main role in this arrangement, producing a rectified sinusoidal current waveform synchronized with the electric grid. The function of the full-bridge inverter, connected in cascade with the Zeta converter, is to reverse every 180° the current generated by the Zeta converter. Initially it presents the analysis of the Zeta converter operating in DCM, as well as a design criterion. Following by the control strategy and the experimental results for the proposed system are presented and discussed. / Este trabalho apresenta um estudo do conversor CC-CC Zeta operando no modo de condução descontínuo, produzindo uma corrente senoidal retificada em sua saída, corrente esta que será entregue à rede elétrica comercial através de um inversor de ponte completa operando em baixa freqüência. O conversor Zeta, em conjunto com o inversor de ponte completa, forma o inversor módulo integrado. Um controle FeedForward é utilizado para se obter a máxima potência disponível nos painéis solares. Este controle é desenvolvido através de aproximações lineares das características elétricas dos painéis solares quando nestes incidem diferentes níveis de insolação e temperatura. É apresentado neste trabalho o modelo de espaços de estados médio para o conversor Zeta operando no modo de condução descontínuo, considerando a resistência interna da maioria dos seus componentes. Simulações e resultados experimentais são apresentados.
266

Projeto de leis de controle robusto do tipo PSC via realimentação de estados aplicada a um sistema UPS

Thomaz, Guilherme January 2009 (has links)
Made available in DSpace on 2013-08-07T18:53:37Z (GMT). No. of bitstreams: 1 000411910-Texto+Completo-0.pdf: 2200612 bytes, checksum: 4c44c72a81a3bd7eec64bd78b4b6c50a (MD5) Previous issue date: 2009 / This work presents an alternative strategy to the control of Uninterruptible Power Supply – UPS. A Proportional–Sinusoidal–Cosinusoidal (PSC) is used for to voltage regulation loop. The controller parameters are determined by means of a convex optimization problem subject to a set of linear matrix inequalities (LMIs). This parameters set a closed loop control that place all the closed loop poles in a determined region of the s plane and minimize an upper bound on the system H∞-norm, which minimizes the load variation effect in the output voltage of the UPS. A commercial UPS, controlled by PID (Proportional - Integral – Derivate), and its performance tests using linear and non-linear load are shown in this work. Finally, the PID action is replaced by the alternative strategy proposed (PSC Controller). New tests and simulations are realized. The simulations and the experimental results using PSC Controller are better than the ones in which PID Controller was used, without increasing the hardware cost commercially used. This fact proves the possibility to use PSC control strategy in a commercial UPS. / Esta dissertação apresenta o desenvolvimento e a implementação de uma estratégia alternativa para o controle da tensão de saída em Fontes Ininterruptas de Energia (também chamadas de UPS - Uninterruptible Power Supply). Esta estratégia é denominada Controlador Proporcional, Senoidal e Cossenoidal (PSC). Os ganhos deste controlador são obtidos através de técnicas de otimização convexa baseadas na formulação LMI (Linear Matrix Inequality). Através destas técnicas, determina-se um controlador do tipo realimentação de estados tal que os pólos em malha fechada do sistema estejam contidos em uma especificada região no plano s, além de minimizar um limitante superior da norma H do sistema, de forma a minimizar a influência de distúrbios da carga na tensão de saída da UPS. Uma UPS comercial, controlada através de um Controlador PID (Proporcional, Integral e Derivativo), é apresentada neste trabalho, bem como, seus testes de desempenho mediante carga linear e não-linear. Por fim, troca-se a ação do Controlador PID pela estratégia alternativa proposta (Controlador PSC) e realizam-se novas simulações e novos testes. Observa-se em todos os resultados apresentados, tanto simulados quanto práticos, uma melhora bastante significativa devido à utilização do Controlador PSC, sem acréscimo de custo no hardware utilizado comercialmente. Com isto, confirma-se a viabilidade da utilização desta estratégia de controle em UPS comerciais.
267

Controle por realimentação linear de variáveis de estado com modelo interno senoidal aplicado a fontes ininterruptas de energia

Nazário, Cristiano Zanini January 2007 (has links)
Made available in DSpace on 2013-08-07T18:53:40Z (GMT). No. of bitstreams: 1 000395024-Texto+Completo-0.pdf: 4205635 bytes, checksum: 4ff717d6f44bb5107e794fe791c50d37 (MD5) Previous issue date: 2007 / The evolution of power electronics devices in the last decades is followed by the development of alternative control strategies with applications on power electronics converters. A family of these converters is employed for the design of commercial Uninterruptible Power Supplies - UPS. In this work, it is proposed an alternative strategy to the control of an Uninterruptible Power Supply – UPS. An Sinusoidal Internal Model Control Sinusoidal – SIMC – is used for the voltage regulation loop, while a Linear Variable State Feedback - LVSF – is employed to improve the current loop dynamics. The obtained results are compared with the traditional Proportional-Integral-Derivative – PID –controller, by means of a commercial UPS showing the effectiveness of the proposed control scheme. / A evolução dos componentes eletrônicos de potência das últimas décadas, seguida de diferentes estratégias de controle desenvolvidas para conversores de potência está resultando em diferentes aplicações dos conversores de potência. Uma família destes conversores é utilizada como parte do projeto de uma Fonte Ininterrupta de Energia comercial. Esta dissertação apresenta uma estratégia alternativa para controlar uma Fonte Ininterrupta de Energia ou do Inglês UPS – Uninterruptible Power Supply. Um controle com Modelo Interno Senoidal é utilizado para realimentação da tensão de saída, enquanto uma Realimentação Linear da Variável de Estado “corrente do Indutor”, é utilizada para melhorar as características dinâmicas do UPS. Os resultados obtidos são comparados com um controlador PID clássico, sendo ambos os controles aplicados a um UPS comercial.
268

Efeitos do treinamento pliométrico com e sem indução de potencialização pós-ativação no desempenho de saltos de atletas em atleta de voleibol

Berriel, Guilherme Pereira January 2016 (has links)
O efeito da potencialização pós-ativação (PPA) tem sido estudado, mas a sua aplicação no desempenho de atletas é muito controversa. Estudos descrevem a possibilidade de que a PPA possa compensar o mecanismo de fadiga, aumentando a taxa de desenvolvimento de força e melhorando a potência muscular. O objetivo deste estudo foi avaliar os efeitos agudos e crônicos de um treinamento pliométrico com e sem indução da PPA na potência muscular de membros inferiores em atletas de voleibol. A amostra foi composta por 16 atletas de voleibol masculino participantes da Superliga Nacional, divididos em grupo pliométrico (GPLIO) e grupo PPA (GPPA). O grupo pliométrico foi submetido a um treinamento de pliometria e o grupo PPA acrescentou ao treinamento pliométrico uma rotina de treinos que estimularam o mecanismo de PPA. O período de treinamento foi de 4 semanas com 2 sessões semanais. Durante a avaliação do pré e pós-treinamento para a determinação dos efeitos crônicos, foi mensurada a potência muscular dos membros inferiores através do salto vertical counter movement jump (CMJ), conforme protocolo sugerido por Bosco (1994), em uma plataforma de força, e contração voluntária máxima para a musculatura da articulação do joelho em um equipamento isocinético. Na avaliação pré e pós-teste para a determinação do efeito agudo, foi utilizado um tapete de contato para obtenção da altura de salto vertical CMJ. Para análise estatística foi utilizado o teste de equações de estimação generalizadas (GEE) no fator tempo e no fator grupo para determinar os efeitos do treinamento em cada grupo (GPLIO e GPPA). Os resultados referente aos efeitos agudos indicam a interação grupo*tempo para o grupo PPA significativa de p<0,001 (38,26 cms / 44,51 cms) do período pré-treinamento para o período de treinamento e de p=0,002 (38,26 cms /44,07 cms) do período pré para o pós treinamento. Ainda observamos que o grupo PPA obteve altura de salto significativamente melhor ao grupo PLIO, tanto no período de treinamento (44,51 cms/35,38cms) como no pós-treinamento pliométrico (44,07cms / 39,32 cms). Quanto aos efeitos crônicos, os resultados demonstraram não haver diferença significativa para as variáveis de torque isocinético. No que diz respeito à altura e potência de salto após o treinamento crônico foi observada diferença significativa nos dois grupos do período pré para o pós-treinamento, não havendo diferença entre os grupos. Concluímos que o treinamento pliométrico com indução de PPA melhora os efeitos agudos do salto vertical, tanto durante o treinamento como até 80 minutos após o treinamento pliométrico. Já no que diz respeito aos efeitos crônicos da indução ou não de PPA no treinamento pliométrico, os resultados indicam não haver diferença significativa no torque isocinético dos músculos extensores do joelho, porém na altura de salto CMJ e potência os resultados indicam que os dois modelos de treinamento têm uma resposta semelhante. / The effect of post-activation potentiation (PPA) has been studied, but its application in the performance of athletes is very controversial. Studies have described the possibility that PPP can compensate for the fatigue mechanism, increasing the rate of strength development and improving muscle power. The objective of this study was to evaluate the acute and chronic effects of a plyometric training with and without PPA induction on lower limb muscle power in volleyball athletes. The sample consisted of 16 male volleyball players participating in the National Superliga, divided into plyometric group (GPLIO) and PPA group (GPPA). The plyometric group underwent a plyometrics training and the PPA group added to the plyometric training a routine of training that stimulated the PPA mechanism. The training period was 4 weeks with 2 weekly sessions. During the pre and post-training evaluation for the determination of the chronic effects, the muscular power of the lower limbs was measured through the vertical jump movement movement (CMJ), according to a protocol suggested by Bosco (1994), on a force platform, And maximal voluntary contraction for the musculature of the knee joint in an isokinetic equipment. In the pre and post-test evaluation for the determination of the acute effect, a contact mat was used to obtain the vertical jump height CMJ. For statistical analysis, the test of generalized estimation equations (GEE) in the time factor and in the group factor was used to determine the effects of the training in each group (GPLIO and GPPA). The results for the acute effects indicate the group*time interaction for the PPA group significant of p<0.001 (38.26 cms / 44.51 cms) of the pre-training period for the training period and p=0.002 (38, 26 cm / 44.07 cm) from the pre and post training period. We also observed that the PPA group had a significantly better jump height in the PLIO group, both in the training period (44.51 cm / 35.38 cm) and in the plyometric training (44.07 cm / 39.32 cm). Regarding the chronic effects, the results showed no significant difference for the isokinetic torque variables. Regarding the height and jumping power after the chronic training, a significant difference was observed in the two groups from the pre-post-training period, with no difference between the groups. We conclude that plyometric training with PPA induction improves the acute effects of vertical jump, both during training and up to 80 minutes after plyometric training. Regarding the chronic effects of PPA or non-PPA induction in plyometric training, the results indicate that there is no significant difference in the isokinetic torque of the knee extensor muscles, but at the height of the CMJ and power jump the results indicate that the two models of Have a similar response.
269

Um pacote computacional para a análise estatística de processos de Lei de Potência

Madureira, Israel de Freitas 01 July 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Exatas, Departamento de Estatística, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2014-09-02T14:25:58Z No. of bitstreams: 1 2014_IsraelFreitasMadureira.pdf: 1405902 bytes, checksum: 3bf395b1163f0cde86d8dd900df84336 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-09-22T15:58:45Z (GMT) No. of bitstreams: 1 2014_IsraelFreitasMadureira.pdf: 1405902 bytes, checksum: 3bf395b1163f0cde86d8dd900df84336 (MD5) / Made available in DSpace on 2014-09-22T15:58:45Z (GMT). No. of bitstreams: 1 2014_IsraelFreitasMadureira.pdf: 1405902 bytes, checksum: 3bf395b1163f0cde86d8dd900df84336 (MD5) / Este trabalho teve por objetivo desenvolver e implementar um pacote estatístico escrito em R para análisar a confiabilidade em sistemas reparáveis. O pacote se chama NHPPplp, do inglês Non-homogeneous Poisson Process with Power Law Process intensity. Os dados são modelados de acordo com o Processo de Lei de Pot ência, um dos mais populares modelos paramétricos na literatura de confiabilidade. Os comandos no pacote estimam os parâmetros do modelo e funções deles, além de veri car a qualidade do ajuste. Ele permite elaborar uma Política de Manutenção Preventiva Ótima para sistemas reparáveis. O estudo envolve tanto a abordagem clássica como a bayesiana. ______________________________________________________________________________ ABSTRACT / The objective of the this work is to develop and implement a statistical package written in R to analyze the reliability of repairable systems. The package is called NHPPplp (Non-homogeneous Poisson Process with Power Law Process intensity). The Power Law Process is one of the most popular parametric models in the reliability literature. The functions available in the package estimates the model parameters and function of them and also veri es the goodness-of- t. It allows the user to estimate an Optimal Preventive Policy for repairable systems. The approach includes both classical and bayesian inference.
270

Uma eficiente abordagem na operação de reservatórios para geração de energia elétrica / not available

Kátia Lívia Zambon 25 November 1997 (has links)
Este trabalho apresenta uma nova abordagem para o Planejamento Energético da Operação de Sistemas Hidrotérmicos de Potência, com uma formulação que permite a solução do problema por técnicas de programação linear, ao contrário de sua forma original, onde o mesmo é complexo e de difícil solução. Utilizando esta formulação, os aspectos físicos importantes do sistema foram preservados, tais como a representação individualizada das usinas, as características da função de custo com crescimento exponencial e o efeito cota, o qual foi inserido na função objetivo através de parcelas de penalização, com pesos distintos para cada usina, priorizando o enchimento dos reservatórios na cascata, fundamental no comportamento operativo ótimo. Além disso, esta formulação pode abrir caminhos para abordagens estocásticas. Os modelos foram desenvolvidos a partir da adoção de uma forma linear para a função de geração das usinas hidroelétricas, realizando-se posteriormente uma linearização da função de custo do problema. A solução foi dada por duas técnicas de linearização, em conjunto com dois métodos de separabilidade da função, e também pela técnica da programação quadrática. Aos vários modelos obtidos, foi aplicado o Método Simplex de resolução, com alguma modificação, que é eficiente, rápido e simples, ao contrário das técnicas de programação não linear que apresentam dificuldades de convergência em muitos casos. Todos os métodos de otimização propostos foram implementados especificamente para a solução do problema em questão, observando-se os desempenhos da operação e também aspectos computacionais. Os resultados foram analisados através do comportamento dos sistemas testes, por meio de gráficos de trajetória de volume, custo marginal de operação e índices numéricos de desempenho. As performances encontradas foram comparadas entre si e com as obtidas por técnicas de programação não linear, mostrando-se eficientes, com resultados muito bons e bem próximos do comportamento operativo ótimo dos reservatórios. / This work presents a new approach for the Scheduling of Hydrothermal Systems, with a formulation that allows the solution of the problem through the linear programming technics, otherwise the original form, which is complex and difficult. The models were developed through a linear form for the generation function of hydroelectric plant, successive of the linearization of the cost function of the problem. The linear technics used were the Simplex Method, with some modification, that is efficient, fast and simple. The important physical aspects of the system were preserved, like the individual representation of the hydroelectric plant, the features of cost function with the exponential increase and the head effect. Besides, this formulation can lead to estocastic approachs. All the optimization methods were implemented for the solution of the problem. The performances obtained were compared with each other and with that obtained through the non linear technics. The algorithms showed to be efficient, with good results and very near to the optimal behavior of the reservoir operation planning obtained by traditional methods.

Page generated in 0.0669 seconds