• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação in vitro dos efeitos da aplicação de sistemas adesivos, do oxalato de potássio, ou a combinação de ambos, na permeabilidade dentinária / Effects of a potassium oxalate gel/adhesive agent combined application on dentin permeability: an in vitro study

Silva, Safira Marques de Andrade e 17 June 2005 (has links)
A tendência atual de simplificação de sistemas adesivos transformou-os em polímeros altamente hidrofílicos e prontamente susceptíveis à permeação de água através de sua estrutura. Estudos recentes têm demonstrado que os sistemas adesivos simplificados se comportam como membranas semipermeáveis, permitindo o movimento de fluidos através da sua estrutura. Soluções a base de oxalato de potássio são efetivos agentes de redução da condutividade hidráulica dentinária. Quando são aplicados na dentina após o condicionamento ácido, podem ser utilizados em associação com os sistemas adesivos sem o comprometimento da adesão. Este trabalho objetivou avaliar os efeitos dos sistemas adesivos AdheSE, One Up Bond F e Single Bond, associados ou não a uma solução a base de oxalato de potássio, na condutividade hidráulica da dentina. Foram realizados preparos de coroas totais em terceiros molares humanos que tiveram suas raízes secionadas e a polpa coronária removida. Os segmentos coronários obtidos foram conectados ao ?Medidor de Fluxo? (Flodec?System, De marco Engineering, Switzerland). A condutividade hidráulica dos espécimes foi mensurada antes e após a aplicação dos sistemas adesivos Single Bond -3M ESPE, One UP Bond F -Tokuyama Inc, AdheSe- Ivoclar- Vivadent. Os adesivos foram aplicados seguindo as recomendações do fabricante (grupos SBF, ADF e OBF), de forma experimental (grupos ADE e OBE), e em combinação com uma solução a base de oxalato de potássio (grupos SBO, ADO e OBO). Cada espécime teve seu valor de permeabilidade original ( smear layer) e máxima (após condicionamento ácido) medidos anteriormente, os quais serviram como parâmetros para o cálculo das respectivas alterações frente aos tratamentos, expressas em porcentagem. Após a determinação da condutividade hidráulica, os preparos foram moldados para obtenção de réplicas em resina, as quais foram examinadas em MEV (JEOL 2800, Japão) para qualificar a permeação de fluido através do adesivo. A Análise de variância a 2 critérios mostrou que apesar dos procedimentos adesivos causarem uma redução significante (p< 0.05) na condutividade hidráulica da dentina condicionada, nenhum foi capaz de eliminar completamente a passagem de fluidos através do adesivo polimerizado. Para os três adesivos testados, o tratamento com o oxalato de potássio foi o tratamento mais eficaz na redução da permeabilidade dentinária e esta diferença foi estatisticamente significante quando comparada aos outros tratamentos (p<0,05). Não houve diferença entre os três sistemas adesivos estudados com relação à redução da permeabilidade dentinária (p> 0,05). A análise das réplicas em MEV mostrou que mesmo após a polimerização do adesivo, a transudação de fluidos pôde ser identificada na superfície de todas réplicas examinadas. Nenhum dos sistemas adesivos testados foi capaz de eliminar a permeação de fluidos através da dentina, contudo a associação destes adesivos com uma solução a base de oxalato de potássio reduziu de forma significante a permeabilidade dentinária. / There is an ongoing trend to move away from classical multi-component bonding systems toward simplified adhesives. An immediate consequence of adhesive simplification is the intrinsic permeability to water that result from their increase in hydrophilicity. Current studies have demonstrated that single-step adhesives may act as semi-permeable membranes that allow water diffusion through its structure. Oxalate desensitizers are effective in reducing the hydraulic conductance of dentin. When oxalates are used after acid- etching they do not interfere with subsequent resin bonding. The objective of this study was to test the effects of adhesives systems with or without the application of an oxalate desensitizer on dentin permeability. Crown preparations were made from human extracted teeth. After the roots were sectioned and the coronal pulp removed, the crown segments were connected to an automatic flow-recording device (Flodec-System, De Marco Engineering, Switzerland). Fluid conductance was measured before and after the bonding procedures with the adhesives Single Bond -3M ESPE, One UP Bond F -Tokuyama Inc and AdheSe- Ivoclar Vivadent. Specimens were prepared and tested after the surface had been bonded according to manufacturer?s instructions (SBF,ADF and OBF groups) , in a experimental way (ADE and OBE groups) or integrating with a oxalate desensitizer gel (SBO, ADO and OBO groups). For each specimen, fluid flow across the smear-layer and bonded dentin was expressed as a percentage of acidetched dentin, which was assigned a value of 100% flow rate. After the hydraulic conductance measures, impressions were taken from the crown segments and epoxy resin replicas were produced for SEM examination. Two-Way ANOVA reveled that the adhesive systems reduced dentin permeability significantly (p< 0.05) compared to acid etched dentin, but no bonding system was able to eliminate the fluid flow though dentin. For the three bonding systems tested, treating the acid-etched dentin with potassium oxalate prior to the application of the adhesive was the most effective in reducing the hydraulic conductance of the specimens, and this difference was significant (p< 0.05) when comparing to the other treatments. There were no significant differences among the adhesives in their ability to reduce dentin permeability (p> 0.05). SEM micrographs of resin replicas showed that transudation of dentinal fluid droplets could be identified on the surfaces of all replicas examined.
2

Avaliação in vitro dos efeitos da aplicação de sistemas adesivos, do oxalato de potássio, ou a combinação de ambos, na permeabilidade dentinária / Effects of a potassium oxalate gel/adhesive agent combined application on dentin permeability: an in vitro study

Safira Marques de Andrade e Silva 17 June 2005 (has links)
A tendência atual de simplificação de sistemas adesivos transformou-os em polímeros altamente hidrofílicos e prontamente susceptíveis à permeação de água através de sua estrutura. Estudos recentes têm demonstrado que os sistemas adesivos simplificados se comportam como membranas semipermeáveis, permitindo o movimento de fluidos através da sua estrutura. Soluções a base de oxalato de potássio são efetivos agentes de redução da condutividade hidráulica dentinária. Quando são aplicados na dentina após o condicionamento ácido, podem ser utilizados em associação com os sistemas adesivos sem o comprometimento da adesão. Este trabalho objetivou avaliar os efeitos dos sistemas adesivos AdheSE, One Up Bond F e Single Bond, associados ou não a uma solução a base de oxalato de potássio, na condutividade hidráulica da dentina. Foram realizados preparos de coroas totais em terceiros molares humanos que tiveram suas raízes secionadas e a polpa coronária removida. Os segmentos coronários obtidos foram conectados ao ?Medidor de Fluxo? (Flodec?System, De marco Engineering, Switzerland). A condutividade hidráulica dos espécimes foi mensurada antes e após a aplicação dos sistemas adesivos Single Bond -3M ESPE, One UP Bond F -Tokuyama Inc, AdheSe- Ivoclar- Vivadent. Os adesivos foram aplicados seguindo as recomendações do fabricante (grupos SBF, ADF e OBF), de forma experimental (grupos ADE e OBE), e em combinação com uma solução a base de oxalato de potássio (grupos SBO, ADO e OBO). Cada espécime teve seu valor de permeabilidade original ( smear layer) e máxima (após condicionamento ácido) medidos anteriormente, os quais serviram como parâmetros para o cálculo das respectivas alterações frente aos tratamentos, expressas em porcentagem. Após a determinação da condutividade hidráulica, os preparos foram moldados para obtenção de réplicas em resina, as quais foram examinadas em MEV (JEOL 2800, Japão) para qualificar a permeação de fluido através do adesivo. A Análise de variância a 2 critérios mostrou que apesar dos procedimentos adesivos causarem uma redução significante (p< 0.05) na condutividade hidráulica da dentina condicionada, nenhum foi capaz de eliminar completamente a passagem de fluidos através do adesivo polimerizado. Para os três adesivos testados, o tratamento com o oxalato de potássio foi o tratamento mais eficaz na redução da permeabilidade dentinária e esta diferença foi estatisticamente significante quando comparada aos outros tratamentos (p<0,05). Não houve diferença entre os três sistemas adesivos estudados com relação à redução da permeabilidade dentinária (p> 0,05). A análise das réplicas em MEV mostrou que mesmo após a polimerização do adesivo, a transudação de fluidos pôde ser identificada na superfície de todas réplicas examinadas. Nenhum dos sistemas adesivos testados foi capaz de eliminar a permeação de fluidos através da dentina, contudo a associação destes adesivos com uma solução a base de oxalato de potássio reduziu de forma significante a permeabilidade dentinária. / There is an ongoing trend to move away from classical multi-component bonding systems toward simplified adhesives. An immediate consequence of adhesive simplification is the intrinsic permeability to water that result from their increase in hydrophilicity. Current studies have demonstrated that single-step adhesives may act as semi-permeable membranes that allow water diffusion through its structure. Oxalate desensitizers are effective in reducing the hydraulic conductance of dentin. When oxalates are used after acid- etching they do not interfere with subsequent resin bonding. The objective of this study was to test the effects of adhesives systems with or without the application of an oxalate desensitizer on dentin permeability. Crown preparations were made from human extracted teeth. After the roots were sectioned and the coronal pulp removed, the crown segments were connected to an automatic flow-recording device (Flodec-System, De Marco Engineering, Switzerland). Fluid conductance was measured before and after the bonding procedures with the adhesives Single Bond -3M ESPE, One UP Bond F -Tokuyama Inc and AdheSe- Ivoclar Vivadent. Specimens were prepared and tested after the surface had been bonded according to manufacturer?s instructions (SBF,ADF and OBF groups) , in a experimental way (ADE and OBE groups) or integrating with a oxalate desensitizer gel (SBO, ADO and OBO groups). For each specimen, fluid flow across the smear-layer and bonded dentin was expressed as a percentage of acidetched dentin, which was assigned a value of 100% flow rate. After the hydraulic conductance measures, impressions were taken from the crown segments and epoxy resin replicas were produced for SEM examination. Two-Way ANOVA reveled that the adhesive systems reduced dentin permeability significantly (p< 0.05) compared to acid etched dentin, but no bonding system was able to eliminate the fluid flow though dentin. For the three bonding systems tested, treating the acid-etched dentin with potassium oxalate prior to the application of the adhesive was the most effective in reducing the hydraulic conductance of the specimens, and this difference was significant (p< 0.05) when comparing to the other treatments. There were no significant differences among the adhesives in their ability to reduce dentin permeability (p> 0.05). SEM micrographs of resin replicas showed that transudation of dentinal fluid droplets could be identified on the surfaces of all replicas examined.
3

Method verification for homocysteine and a sustainability study on glucose, homocysteine and lactate in different sampling tubes

Bohjort, Emelie January 2016 (has links)
The pre-analytical phase is known for being the most important step in the laboratory process to reach reliable test results. If handling, transport or preparation of the sample is performed incorrectly the results can deviate from the true value. Today, sampling tubes contains various additives to stabilize concentration levels. The aim of this study was to test a new sampling tube containing fluoride/citrate for glucose, lactate and homocysteine. It was also of interest to evaluate the stability of those three analytes in lithium-heparin, sodium-fluoride/potassium oxalate and fluoride/citrate tubes. To perform the sustainability study, a method verification was done for homocysteine in plasma. The study was performed in a hospital laboratory on the routine instrument Roche Cobas 6000 analyzer. Blood was drawn from 20 patients and was analyzed at the hospital laboratory in Gävle. The blood samples were transported frozen to the laboratory in Hudiksvall and were used in the method verification. For the sustainability study, blood was drawn from 10 healthy volunteers in lithium-heparin, sodium-fluoride/potassium oxalate and fluoride/citrate tubes. The method verification was approved. The results showed that glucose was stable for up to 72 hours in Vacuette Glycaemia tube with fluoride/citrate and this tube also gave more accurate results. Lactate and homocysteine were also stable in fluoride/citrate, but needs further studies. All three analytes were more stable if the sample tubes were centrifuged as soon as possible after blood collection. Fluoride/citrate tubes were stable without centrifugation directly.
4

Estudo in vitro do efeito de agentes anti-hiperestésicos na permeabilidade dentinária por meio de testes de condutividade hidráulica e de espectroscopia de impedância eletroquímica / In vitro study of the effect of anti-hyperesthesic agents in dentin permeability through hydraulic conductance and electrochemical impedance spectroscopy

Canova, Giovana Calicchio 20 September 2007 (has links)
O objetivo do presente estudo foi quantificar, in vitro, a permeabilidade da dentina tratada com dois agentes anti-hiperestésicos à base de oxalato e um à base de fosfato de cálcio, por meio de testes de condutividade hidráulica e de espectroscopia de impedância eletroquímica e, ainda, determinar se espectroscopia de impedância eletroquímica pode ser considerada um método alternativo para avaliar a capacidade obstrutiva de agentes antihiperestésicos. Para o teste de condutividade hidráulica foram utilizados vinte quatro discos de dentina, obtidos de terceiros molares humanos extraídos, que foram divididos em três grupos de oito espécimes, correspondentes aos três materiais testados: gel Experimental, Sensi Kill e BisBlock. Outros dezoito discos foram selecionados para o teste de espectroscopia de impedância eletroquímica, sendo divididos em três grupos de seis espécimes, correspondentes aos três agentes anti-hiperestésicos citados anteriormente. Para ambos os testes as medidas foram realizadas nas seguintes condições: na presença de smear layer; após condicionamento com ácido fosfórico a 37% e após a aplicação dos materiais na superfície oclusal dos discos de dentina. Com base na análise estatística dos resultados, verificou-se, por meio dos dois métodos utilizados, que o gel Experimental e o BisBlock apresentaram efeitos estatisticamente semelhantes na redução da permeabilidade e foram significantemente mais eficientes que o Sensi Kill. Pode-se concluir que os agentes anti-hiperestésicos Experimental e BisBlock mostraram-se efetivos na redução da permeabilidade dentinária, pelos dois métodos de avaliação, e que o método de espectroscopia de impedância eletroquímica pode ser considerado um método alternativo para a avaliação da capacidade obstrutiva de agentes anti-hiperestésicos. / The aim of the present study was to quantify in vitro the dentin permeability of dentin treated with two potassium oxalate dentin desensitizers and one calcium phosphate agent through hydraulic conductance (Lp) and eletrochemical impedance spectroscopy (EIS) tests and, yet, to determine whether EIS may be considered a suitable alternative method to evaluate the occlusive capacity of the dentin desensitizers. For the hydraulic conductance, twenty-four dentin discs were obtained from extracted human third molars, which were divided into three groups of eight specimens, corresponding to the materials to be tested: Experimental gel, Sensi Kill and BisBlock. Other eighteen dentin discs were selected for theEIS and divided into three groups of six specimens corresponding to the three dentin desensitizers mentioned before. For both tests, the following conditions were measured: in the presence of smear layer, after 37% phosphoric acid etching and after the application of the tested materials in the occlusal surfaces of dentin discs. Based upon the statistical analysis of the results, it was demonstrated by both methods that Experimental gel and BisBlock performed statistically similarly in reducing dentin permeability and were significantly more efficient that Sensi Kill. It can be concluded that the dentin desensitizers Experimental e BisBlock were demonstrated to be effective in the reduction of dentin permeability by both experimental methods and that EIS may be considered as an alternative method for the evaluation of the obstructive capacity of dentin desensitizers.
5

Estudo in vitro do efeito de agentes anti-hiperestésicos na permeabilidade dentinária por meio de testes de condutividade hidráulica e de espectroscopia de impedância eletroquímica / In vitro study of the effect of anti-hyperesthesic agents in dentin permeability through hydraulic conductance and electrochemical impedance spectroscopy

Giovana Calicchio Canova 20 September 2007 (has links)
O objetivo do presente estudo foi quantificar, in vitro, a permeabilidade da dentina tratada com dois agentes anti-hiperestésicos à base de oxalato e um à base de fosfato de cálcio, por meio de testes de condutividade hidráulica e de espectroscopia de impedância eletroquímica e, ainda, determinar se espectroscopia de impedância eletroquímica pode ser considerada um método alternativo para avaliar a capacidade obstrutiva de agentes antihiperestésicos. Para o teste de condutividade hidráulica foram utilizados vinte quatro discos de dentina, obtidos de terceiros molares humanos extraídos, que foram divididos em três grupos de oito espécimes, correspondentes aos três materiais testados: gel Experimental, Sensi Kill e BisBlock. Outros dezoito discos foram selecionados para o teste de espectroscopia de impedância eletroquímica, sendo divididos em três grupos de seis espécimes, correspondentes aos três agentes anti-hiperestésicos citados anteriormente. Para ambos os testes as medidas foram realizadas nas seguintes condições: na presença de smear layer; após condicionamento com ácido fosfórico a 37% e após a aplicação dos materiais na superfície oclusal dos discos de dentina. Com base na análise estatística dos resultados, verificou-se, por meio dos dois métodos utilizados, que o gel Experimental e o BisBlock apresentaram efeitos estatisticamente semelhantes na redução da permeabilidade e foram significantemente mais eficientes que o Sensi Kill. Pode-se concluir que os agentes anti-hiperestésicos Experimental e BisBlock mostraram-se efetivos na redução da permeabilidade dentinária, pelos dois métodos de avaliação, e que o método de espectroscopia de impedância eletroquímica pode ser considerado um método alternativo para a avaliação da capacidade obstrutiva de agentes anti-hiperestésicos. / The aim of the present study was to quantify in vitro the dentin permeability of dentin treated with two potassium oxalate dentin desensitizers and one calcium phosphate agent through hydraulic conductance (Lp) and eletrochemical impedance spectroscopy (EIS) tests and, yet, to determine whether EIS may be considered a suitable alternative method to evaluate the occlusive capacity of the dentin desensitizers. For the hydraulic conductance, twenty-four dentin discs were obtained from extracted human third molars, which were divided into three groups of eight specimens, corresponding to the materials to be tested: Experimental gel, Sensi Kill and BisBlock. Other eighteen dentin discs were selected for theEIS and divided into three groups of six specimens corresponding to the three dentin desensitizers mentioned before. For both tests, the following conditions were measured: in the presence of smear layer, after 37% phosphoric acid etching and after the application of the tested materials in the occlusal surfaces of dentin discs. Based upon the statistical analysis of the results, it was demonstrated by both methods that Experimental gel and BisBlock performed statistically similarly in reducing dentin permeability and were significantly more efficient that Sensi Kill. It can be concluded that the dentin desensitizers Experimental e BisBlock were demonstrated to be effective in the reduction of dentin permeability by both experimental methods and that EIS may be considered as an alternative method for the evaluation of the obstructive capacity of dentin desensitizers.

Page generated in 0.0558 seconds