• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • Tagged with
  • 17
  • 17
  • 17
  • 10
  • 10
  • 10
  • 10
  • 8
  • 8
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de diferentes materiais utilizados no selamento da íris protética em relação à tinta acrílica utilizada em sua pintura / Evaluation of different materials used in prosthetic iris painting sealing and their relation to the acrylic paint

Pereira, Shanon Leite 18 December 2007 (has links)
Na confecção de uma prótese ocular a íris artificial é a estrutura responsável pela sua dissimulação e estética. O propósito do presente trabalho foi avaliar a interação tinta e selamento utilizados na pintura da íris protética, verificando as falhas e insucessos na fase de prensagem da íris no corpo escleral. Para este estudo, foram confeccionados quatro tipos de corpos de prova sendo, dez calotas lisas utilizando cianoacrilato como selante, dez calotas lisas utilizando polímero de acetato de vinila como selante, dez calotas despolidas utilizando cianoacrilato como selante e dez calotas despolidas utilizando polímero de acetato de vinila como selante. Os corposde- prova foram submetidos a uma análise em uma lupa estereoscópica para verificação da presença de falhas, e um corpo de prova de cada grupo foi levado a um microscópio eletrônico de varredura para estudo morfológico. Nenhum corpo de prova apresentou alteração macroscopicamente, comprovando que o protocolo utilizado é eficaz podendo-se concluir que as falhas que ocorrem na confecção de próteses oculares são decorrentes de falhas em alguma fase do protocolo. Entretanto foram observados defeitos microscópicos nos grupos selados com cola de cianoacrilato. / In the manufacturing of ocular prosthesis, the artificial iris is the structure responsible for its dissimulation and esthetic. The aim of this study was to evaluate interaction between paint and sealing material used in prosthetic iris painting, attempting to failures on packing of iris shell in sclera resin. It were studied four different groups, ten smooth shells sealed with cianoacrylate, ten smooth shells sealed with vinyl acetate polymer, ten rough shells sealed with ciaoacrylate and ten rough shells sealed with cianoacrylate. Specimens were analyzed with a stereoscopic magnifying glass for detection of failures, and one specimen of each group was analyzed in a scanning electron microscope for morphological analysis. None of the specimens presented failures macroscopically, which demonstrates that the protocol employed in the present study is effective; it can be concluded that failures in manufacturing of ocular prosthesis are consequence of mistakes in one of the steps of the protocol. However, it was detected microscopic defects in specimens of the groups sealed with cianoacrylate adhesive.
2

Avaliação de diferentes materiais utilizados no selamento da íris protética em relação à tinta acrílica utilizada em sua pintura / Evaluation of different materials used in prosthetic iris painting sealing and their relation to the acrylic paint

Shanon Leite Pereira 18 December 2007 (has links)
Na confecção de uma prótese ocular a íris artificial é a estrutura responsável pela sua dissimulação e estética. O propósito do presente trabalho foi avaliar a interação tinta e selamento utilizados na pintura da íris protética, verificando as falhas e insucessos na fase de prensagem da íris no corpo escleral. Para este estudo, foram confeccionados quatro tipos de corpos de prova sendo, dez calotas lisas utilizando cianoacrilato como selante, dez calotas lisas utilizando polímero de acetato de vinila como selante, dez calotas despolidas utilizando cianoacrilato como selante e dez calotas despolidas utilizando polímero de acetato de vinila como selante. Os corposde- prova foram submetidos a uma análise em uma lupa estereoscópica para verificação da presença de falhas, e um corpo de prova de cada grupo foi levado a um microscópio eletrônico de varredura para estudo morfológico. Nenhum corpo de prova apresentou alteração macroscopicamente, comprovando que o protocolo utilizado é eficaz podendo-se concluir que as falhas que ocorrem na confecção de próteses oculares são decorrentes de falhas em alguma fase do protocolo. Entretanto foram observados defeitos microscópicos nos grupos selados com cola de cianoacrilato. / In the manufacturing of ocular prosthesis, the artificial iris is the structure responsible for its dissimulation and esthetic. The aim of this study was to evaluate interaction between paint and sealing material used in prosthetic iris painting, attempting to failures on packing of iris shell in sclera resin. It were studied four different groups, ten smooth shells sealed with cianoacrylate, ten smooth shells sealed with vinyl acetate polymer, ten rough shells sealed with ciaoacrylate and ten rough shells sealed with cianoacrylate. Specimens were analyzed with a stereoscopic magnifying glass for detection of failures, and one specimen of each group was analyzed in a scanning electron microscope for morphological analysis. None of the specimens presented failures macroscopically, which demonstrates that the protocol employed in the present study is effective; it can be concluded that failures in manufacturing of ocular prosthesis are consequence of mistakes in one of the steps of the protocol. However, it was detected microscopic defects in specimens of the groups sealed with cianoacrylate adhesive.
3

Avaliação clínica da atividade eletromiográfica dos músculos óculo motores em pacientes portadores de próteses oculares individualizadas / Clinical evaluation of the electromyographic activity of the eye muscles in patients with individualized ocular prostheses

Hotta, Patricia Tiemy Hirono 07 August 2012 (has links)
As próteses oculares têm a função de restabelecer a estética simultaneamente à manutenção da forma anatômica da cavidade orbital, preservando o tônus muscular palpebral e inibindo o colapso palpebral. Como poucos trabalhos científicos foram realizados para avaliar a recuperação de tônus muscular em indivíduos com necessidade de próteses oculares, este trabalho teve o objetivo de quantificar, por meio da eletromiografia, essa qualidade muscular e observar a atividade dos músculos óculo motores em pacientes não reabilitados, reabilitados e controle. A atividade eletromiográfica foi captada durante os repousos inicial e final e atividades que envolveram efetiva participação da musculatura nas seguintes condições clínicas: abertura e fechamento normais das pálpebras e abertura e fechamento forçados das pálpebras. Diante dos resultados apresentados nesse estudo, observou-se que a prótese ocular individualizada não interfere nos músculos óculo motores da hemiface contralateral à reabilitada; o contato da prótese ocular nos tecidos musculares remanescentes da cavidade anoftálmica realiza efeito mioestimulador e tanto no grupo reabilitado como no grupo controle, houve maior atividade eletromiográfica nos músculos orbiculares inferiores na ação de abertura e fechamento. / The ocular prosthesis is meant to restore the aesthetics while maintaining the anatomical shape of the orbital cavity, preserving the eyelid muscle tone by inhibiting the breakdown of the eyelid. As few scientific studies were conducted to evaluate the recovery of muscle tone in individuals that need ocular prosthesis, this study aimed through electromyography evaluate this muscle quality and observe the activity of eye muscles in patients not rehabilitated, rehabilitated and control. Electromyographic activity was captured during initial and final rest positions and activities involving active participation of muscles in the following clinical conditions: normal opening and closing eyelid and forced opening and closing eyelid. From the results presented in this study, it was concluded that the ocular prosthesis does not interfered in individual ocular motor muscles of the rehabilitated contralateral hemiface; the ocular prosthesis contact on the remaining tissue of the anophthalmic cavity did myostimulator effects, in the rehabilitated and control groups, EMG activities were greater in lower orbicular muscles at opening and closing actions.
4

Avaliação da íris de prótese ocular obtida através de imagem digitalizada impressa em papel fotográfico / Iris evaluation of ocular prosthesis obtained through digitalized image printed in photographic paper

Reis, Ricardo Cesar dos 11 April 2008 (has links)
A reprodução fiel da íris do olho remanescente na confecção da prótese ocular é fator fundamental no resultado estético e na dissimulação da perda para os pacientes afetados. Este trabalho apresenta uma nova técnica de confecção da íris protética, substituindo a pintura tradicional da mesma, pela imagem digitalizada da íris remanescente, obtida através de fotografia impressa em papel fotográfico. Decidiu-se avaliar a estabilidade das cores, comparando-se a técnica de pintura com a obtida através da fotografia digital, sob a ação de dois fatores: ação térmica do ciclo de polimerização da resina acrílica na confecção da prótese e a incidência da luz solar, principal agente de fotodegradação que compromete a longevidade das próteses oculares, através de teste de envelhecimento acelerado. Foram assim, confeccionados corpos de prova simulando a íris protética, divididos em dois grupos: pintura e fotografia, nas cores azul, amarelo, preto, marrom e verde. Foi realizada leitura colorimétrica inicial e após submetê-los às condições térmicas de polimerização. Posteriormente os corpos de prova foram testados durante três semanas através de ensaio de envelhecimento acelerado artificialmente com radiação ultravioleta A, com leituras colorimétricas semanais. A análise estatística sugere que, após a polimerização, as cores amarelo e marrom apresentaram diferenças significativas entre os grupos, sendo que, a cor amarelo na amostra pintura apresentou uma degradação um pouco acima do nível clinicamente aceitável. Após o ensaio de envelhecimento, não houve diferença significativa entre as amostras pintura e fotografia para as cores verde e amarelo, com alteração um pouco acima do nível clinicamente aceitável. Para as cores marrom e preto ocorreram diferenças significantes, com variações em níveis clinicamente aceitáveis; para a cor azul em níveis elevados, inviáveis clinicamente tanto na fotografia como na pintura. / The accurate iris reproduction in the making of ocular prosthesis for the remaining eye is a fundamental factor for the loss dissimulation aesthetic result in affected patients. This paper presents a new technique for the making of prosthetic iris that consists in substituting the traditional painting of the prosthesis for a digitalized image of the remaining iris, obtained through a picture printed in a photographic paper. It was decided to evaluate the stability of the colors by comparing the painting technique with the digital picture, for this two factors were considered: thermal conditions of the acrylic resin polymerization cycle in the prosthesis making and incidence of the sun light, which is the main photo degradation agent that affect the longevity of the ocular prosthesis, through the accelerated aging test. Then proof bodies simulating the prosthetic iris were made and divided into two groups: painted (in the colors blue, yellow, black, brown and green) and picture. An initial colorimetric scanning was made before and after submitting the bodies to the thermal conditions of the polymerization process. The proof bodies were then tested artificially for three weeks using the accelerated aging with A-ultraviolet radiation technique and proceeding to colorimetric scans weekly. Statistical analysis suggests that after the temperature action in the polymerization cycle, the yellow and brown color presented significative alteration between both groups and the yellow color in the painted presented degradation slightly above the acceptable clinical level. After the aging test, there was no significant difference between the samples in both groups for the green and yellow colors, however, for the brown and black colors significant differences were observed, with variations in clinically acceptable levels, and for blue color in high levels, clinically impracticable, in both groups.
5

Desenvolvimento e avaliação colorimétrica de íris digitalizada obtida através de impressão em etiqueta autocolante e em adesivo / Development and colorimetric evaluation of iris scanned obtained through sticker printing and adhesive

Reis, Ricardo Cesar dos 06 February 2013 (has links)
Um dos fatores imprescindíveis no resultado estético satisfatório do tratamento reabilitador protético ocular é a reprodução fiel da íris do olho remanescente na íris protética. É a dissimulação da perda para os pacientes afetados. Este trabalho apresenta duas novas técnicas de confecção da íris protética, utilizando imagem digitalizada da íris remanescente, obtida por meio de imagem fotográfica impressa em etiqueta autocolante e em adesivo. Em função da fotodegradação que compromete a longevidade das próteses oculares, decidiu-se avaliar a estabilidade das cores, comparando-se ambas as técnicas, através de teste de envelhecimento acelerado. Para os ensaios foram confeccionados corpos de prova simulando a íris protética, divididos em dois grupos: adesivo e etiqueta autocolante, nas cores verde, azul, marrom e preto. A variação do grau de degradação foi avaliada por leitura colorimétrica inicial e, em três intervalos semanais durante o envelhecimento artificial com radiação ultravioleta. A análise estatística sugere que quando as cores foram avaliadas em função do período de ensaio de envelhecimento artificial, somente na cor azul no grupo adesivo houve diferença estatisticamente significante. Quando avaliadas em função do grupo e período de ensaio, os testes estatísticos indicam que não houve diferença entre as cores entre adesivo. Nenhuma das cores entre os grupos apresentou uma degradação de cor acima do nível clinicamente aceitável. / One of the essential factors in satisfactory final result of ocular prosthetic rehabilitation treatment is a faithful reproduction of the iris of the eye remaining in prosthetic iris. It concealment loss for affected patients. This paper presents two new techniques to manufacture prosthetic iris, using the remaining iris scanned image, obtained by photographic image printed sticker and adhesive. Depending on the photo degradation that compromises the longevity of artificial eyes, decided to evaluate the stability of colors, comparing both techniques, through accelerated aging test. For the tests were prepared specimens simulating prosthetic iris, divided into two groups: adhesive sticker and, in green, blue, brown and black. The variation of the degree of degradation was evaluated by colorimetric reading before and after and three weekly intervals during aging with artificial ultraviolet radiation. Statistical analysis suggests that when the colors were evaluated according to the period of artificial aging test, only in blue color in the adhesive group difference was statistically significant. When evaluated as a function of group and trial period, the statistical tests indicate no difference between the colors of adhesive. None of the colors between the groups showed color degradation above the clinically acceptable level.
6

Neoplasias malignas em cavidade orbitária e reabilitação pós-cirúrgica em um hospital brasileiro de oncologia - estudo retrospectivo de 12 anos / Malignant neoplasms in the orbit and post-surgical rehabilitation in a Brazilian hospital oncology - a retrospective study of 12 years

SIRIANNI, Daniela 06 August 2010 (has links)
Made available in DSpace on 2014-07-29T15:21:56Z (GMT). No. of bitstreams: 1 Dissertacao daniela sirianni.pdf: 497398 bytes, checksum: fd20139664c8c71e41d1aa9caae182c6 (MD5) Previous issue date: 2010-08-06 / Malignant tumors in the orbital cavity often require surgical treatment, however, few studies recording the prevalence of tumors in the orbit and post-surgical rehabilitation through maxillofacial prosthetics. The aim of this study was to investigate the prevalence of malignant tumors in the orbital cavity, employed as the surgical treatment and prosthetic rehabilitation after surgery. A retrospective convenience sample was selected from 269 charts of patients treated at Hospital Araújo Jorge (Goiânia, Goiás, Brazil), regional referral center for cancer treatment and supported by the National Health System, from 1998 to 2009. Data concerning the clinical and pathological, psychological support, rehabilitation, prosthetics and clinical outcome were investigated. Descriptive statistical analysis revealed that the age group ranged from 1 to 92 years, mean 43.5 years, 50.2% of female patients. Tumors were more prevalent basal cell carcinoma (58%), retinoblastoma (17.1%), squamous cell carcinoma of the conjunctiva (7.1%), malignant melanoma (6.7%) and rhabdomyosarcoma (4.5%). Of the total, 250 patients (92.3%) underwent surgery by exenteration (78%) or enucleation (21.6%). Variables associated with the rehabilitation aesthetic eye were age (p <0.001) and type of surgery (p <0.001). It follows then that there are low rates of prosthetic care and psychological care offered to patients and that the process was influenced by the esthetic rehabilitative patient's young age and in cases of surgical enucleation of the eyeball / Tumores malignos em cavidade ocular em geral requerem tratamento cirúrgico, porém, há poucos estudos registrando a prevalência de tumores na região orbital e a reabilitação pós-cirúrgica através de próteses bucomaxilofaciais. O objetivo deste estudo foi investigar a prevalência de tumores malignos na cavidade orbitária, as modalidades cirúrgicas empregadas como tratamento e a reabilitação protética pós-cirúrgica. Uma amostra retrospectiva de conveniência foi selecionada de 269 prontuários de pacientes atendidos no Hospital Araújo Jorge (Goiânia, Goiás, Brasil), referência regional para tratamento oncológico e apoiado pelo Sistema Único de Saúde, no período entre 1998 a 2009. Dados relativos a variáveis clínico-patológicas, suporte psicológico, reabilitação protética e desfecho clínico foram investigados. A análise estatística descritiva revelou que a faixa etária variou de 1 a 92 anos, com média de 43,5 anos, sendo 50,2% dos pacientes do gênero feminino. Os tumores mais prevalentes foram carcinoma basocelular (58%), retinoblastoma (17,1%), carcinoma espinocelular de conjuntiva (7,1%), melanoma maligno (6,7%) e rabdomiossarcoma (4,5%). Do total, 250 pacientes (92,3%) foram submetidos a cirurgia por meio de exenteração (78%) ou enucleação (21,6%). As variáveis associadas a reabilitação estética ocular foram idade (p<0,001) e tipo de cirurgia (p<0,001). Conclui-se, então, que há baixos índices de cuidados protéticos e atenção psicológica oferecida aos pacientes e, que o processo estético reabilitador foi influenciado pela idade jovem do paciente e nos casos de enucleação cirúrgica do globo ocular.
7

Desenvolvimento e avaliação colorimétrica de íris digitalizada obtida através de impressão em etiqueta autocolante e em adesivo / Development and colorimetric evaluation of iris scanned obtained through sticker printing and adhesive

Ricardo Cesar dos Reis 06 February 2013 (has links)
Um dos fatores imprescindíveis no resultado estético satisfatório do tratamento reabilitador protético ocular é a reprodução fiel da íris do olho remanescente na íris protética. É a dissimulação da perda para os pacientes afetados. Este trabalho apresenta duas novas técnicas de confecção da íris protética, utilizando imagem digitalizada da íris remanescente, obtida por meio de imagem fotográfica impressa em etiqueta autocolante e em adesivo. Em função da fotodegradação que compromete a longevidade das próteses oculares, decidiu-se avaliar a estabilidade das cores, comparando-se ambas as técnicas, através de teste de envelhecimento acelerado. Para os ensaios foram confeccionados corpos de prova simulando a íris protética, divididos em dois grupos: adesivo e etiqueta autocolante, nas cores verde, azul, marrom e preto. A variação do grau de degradação foi avaliada por leitura colorimétrica inicial e, em três intervalos semanais durante o envelhecimento artificial com radiação ultravioleta. A análise estatística sugere que quando as cores foram avaliadas em função do período de ensaio de envelhecimento artificial, somente na cor azul no grupo adesivo houve diferença estatisticamente significante. Quando avaliadas em função do grupo e período de ensaio, os testes estatísticos indicam que não houve diferença entre as cores entre adesivo. Nenhuma das cores entre os grupos apresentou uma degradação de cor acima do nível clinicamente aceitável. / One of the essential factors in satisfactory final result of ocular prosthetic rehabilitation treatment is a faithful reproduction of the iris of the eye remaining in prosthetic iris. It concealment loss for affected patients. This paper presents two new techniques to manufacture prosthetic iris, using the remaining iris scanned image, obtained by photographic image printed sticker and adhesive. Depending on the photo degradation that compromises the longevity of artificial eyes, decided to evaluate the stability of colors, comparing both techniques, through accelerated aging test. For the tests were prepared specimens simulating prosthetic iris, divided into two groups: adhesive sticker and, in green, blue, brown and black. The variation of the degree of degradation was evaluated by colorimetric reading before and after and three weekly intervals during aging with artificial ultraviolet radiation. Statistical analysis suggests that when the colors were evaluated according to the period of artificial aging test, only in blue color in the adhesive group difference was statistically significant. When evaluated as a function of group and trial period, the statistical tests indicate no difference between the colors of adhesive. None of the colors between the groups showed color degradation above the clinically acceptable level.
8

Avaliação da íris de prótese ocular obtida através de imagem digitalizada impressa em papel fotográfico / Iris evaluation of ocular prosthesis obtained through digitalized image printed in photographic paper

Ricardo Cesar dos Reis 11 April 2008 (has links)
A reprodução fiel da íris do olho remanescente na confecção da prótese ocular é fator fundamental no resultado estético e na dissimulação da perda para os pacientes afetados. Este trabalho apresenta uma nova técnica de confecção da íris protética, substituindo a pintura tradicional da mesma, pela imagem digitalizada da íris remanescente, obtida através de fotografia impressa em papel fotográfico. Decidiu-se avaliar a estabilidade das cores, comparando-se a técnica de pintura com a obtida através da fotografia digital, sob a ação de dois fatores: ação térmica do ciclo de polimerização da resina acrílica na confecção da prótese e a incidência da luz solar, principal agente de fotodegradação que compromete a longevidade das próteses oculares, através de teste de envelhecimento acelerado. Foram assim, confeccionados corpos de prova simulando a íris protética, divididos em dois grupos: pintura e fotografia, nas cores azul, amarelo, preto, marrom e verde. Foi realizada leitura colorimétrica inicial e após submetê-los às condições térmicas de polimerização. Posteriormente os corpos de prova foram testados durante três semanas através de ensaio de envelhecimento acelerado artificialmente com radiação ultravioleta A, com leituras colorimétricas semanais. A análise estatística sugere que, após a polimerização, as cores amarelo e marrom apresentaram diferenças significativas entre os grupos, sendo que, a cor amarelo na amostra pintura apresentou uma degradação um pouco acima do nível clinicamente aceitável. Após o ensaio de envelhecimento, não houve diferença significativa entre as amostras pintura e fotografia para as cores verde e amarelo, com alteração um pouco acima do nível clinicamente aceitável. Para as cores marrom e preto ocorreram diferenças significantes, com variações em níveis clinicamente aceitáveis; para a cor azul em níveis elevados, inviáveis clinicamente tanto na fotografia como na pintura. / The accurate iris reproduction in the making of ocular prosthesis for the remaining eye is a fundamental factor for the loss dissimulation aesthetic result in affected patients. This paper presents a new technique for the making of prosthetic iris that consists in substituting the traditional painting of the prosthesis for a digitalized image of the remaining iris, obtained through a picture printed in a photographic paper. It was decided to evaluate the stability of the colors by comparing the painting technique with the digital picture, for this two factors were considered: thermal conditions of the acrylic resin polymerization cycle in the prosthesis making and incidence of the sun light, which is the main photo degradation agent that affect the longevity of the ocular prosthesis, through the accelerated aging test. Then proof bodies simulating the prosthetic iris were made and divided into two groups: painted (in the colors blue, yellow, black, brown and green) and picture. An initial colorimetric scanning was made before and after submitting the bodies to the thermal conditions of the polymerization process. The proof bodies were then tested artificially for three weeks using the accelerated aging with A-ultraviolet radiation technique and proceeding to colorimetric scans weekly. Statistical analysis suggests that after the temperature action in the polymerization cycle, the yellow and brown color presented significative alteration between both groups and the yellow color in the painted presented degradation slightly above the acceptable clinical level. After the aging test, there was no significant difference between the samples in both groups for the green and yellow colors, however, for the brown and black colors significant differences were observed, with variations in clinically acceptable levels, and for blue color in high levels, clinically impracticable, in both groups.
9

Avaliação clínica da atividade eletromiográfica dos músculos óculo motores em pacientes portadores de próteses oculares individualizadas / Clinical evaluation of the electromyographic activity of the eye muscles in patients with individualized ocular prostheses

Patricia Tiemy Hirono Hotta 07 August 2012 (has links)
As próteses oculares têm a função de restabelecer a estética simultaneamente à manutenção da forma anatômica da cavidade orbital, preservando o tônus muscular palpebral e inibindo o colapso palpebral. Como poucos trabalhos científicos foram realizados para avaliar a recuperação de tônus muscular em indivíduos com necessidade de próteses oculares, este trabalho teve o objetivo de quantificar, por meio da eletromiografia, essa qualidade muscular e observar a atividade dos músculos óculo motores em pacientes não reabilitados, reabilitados e controle. A atividade eletromiográfica foi captada durante os repousos inicial e final e atividades que envolveram efetiva participação da musculatura nas seguintes condições clínicas: abertura e fechamento normais das pálpebras e abertura e fechamento forçados das pálpebras. Diante dos resultados apresentados nesse estudo, observou-se que a prótese ocular individualizada não interfere nos músculos óculo motores da hemiface contralateral à reabilitada; o contato da prótese ocular nos tecidos musculares remanescentes da cavidade anoftálmica realiza efeito mioestimulador e tanto no grupo reabilitado como no grupo controle, houve maior atividade eletromiográfica nos músculos orbiculares inferiores na ação de abertura e fechamento. / The ocular prosthesis is meant to restore the aesthetics while maintaining the anatomical shape of the orbital cavity, preserving the eyelid muscle tone by inhibiting the breakdown of the eyelid. As few scientific studies were conducted to evaluate the recovery of muscle tone in individuals that need ocular prosthesis, this study aimed through electromyography evaluate this muscle quality and observe the activity of eye muscles in patients not rehabilitated, rehabilitated and control. Electromyographic activity was captured during initial and final rest positions and activities involving active participation of muscles in the following clinical conditions: normal opening and closing eyelid and forced opening and closing eyelid. From the results presented in this study, it was concluded that the ocular prosthesis does not interfered in individual ocular motor muscles of the rehabilitated contralateral hemiface; the ocular prosthesis contact on the remaining tissue of the anophthalmic cavity did myostimulator effects, in the rehabilitated and control groups, EMG activities were greater in lower orbicular muscles at opening and closing actions.
10

"Avaliação da estabilidade de cor da esclera em prótese ocular" / Evaluation of the scleral color stability of ocular prosthesis

Kawabata, Simone Cristina 10 May 2006 (has links)
Baseados no fato de que o corpo escleral sofre alterações progressivas de sua cor no decorrer do tempo, e também pela ausência na literatura específica de trabalhos experimentais relacionados com estas alterações, o presente trabalho tem por objetivo, verificar o desempenho de resinas para esclera e de três tipos de pigmentos neste processo. Os pigmentos utilizados para este fim foram: lápis aquarelável, acrílico termo-polimerizante colorido e pigmento cerâmico; nas cores azul, amarelo e vermelho. Para a realização do experimento, foram confeccionados 100 corpos de prova, sendo 50 de resina para esclera no1e os outros 50 de resina para esclera no2. Cada grupo foi subdividido em 10 subgrupos, com 5 unidades cada, separados em quatro categorias: A, B ,C e E. O grupo A foi caracterizado com lápis aquarelável, o B com resina termo-polimerizável colorida, o C com pigmento cerâmico e o E não recebeu caracterização. Todos os grupos foram recobertos por uma camada de resina incolor. Inicialmente, todos os corpos de prova foram submetidos à análise em um espectrofotômetro acoplado a um sistema de colorimetria. A leitura inicial foi considerada como padrão, sendo as demais, efetuadas a cada 24 horas, até um total de 144 horas intercaladas com ensaios de envelhecimento acelerado por radiação UVA. Os dados colorimétricos, obtidos através das curvas de reflexão de cada amostra, foram utilizados para o cálculo das diferenças de cor. Após o tratamento estatístico dos dados obtidos, foi possível concluir que o lápis aquarelável, nas cores amarela e vermelha e o pigmento cerâmico vermelho, apresentaram uma estabilidade de cor clinicamente aceitável durante todo o tempo experimental. Das duas resinas para esclera avaliadas, a de no2 apresentou melhor estabilidade de cor. / Based on the fact that the sclera of ocular prosthesis presents progressive color alterations with time and due to lack of experimental studies on this topic, the purpose of this study was to evaluate the performance of two types of resins combined with three different kinds of pigments. The pigments used herein were: watercolour pencils, heat-polymerized acrylic resin and ceramic pigment on the colors blue, yellow and red. A total of one-hundred specimens were prepared, among which 50 were made by resin no 1 and the remaining 50 were made by resin no 2. Each group of 50 samples were divided in 10 subgroups containing 5 specimens each, and were separated in four categories: A, B, C and E. Group A was colored with watercolour pencils, while in group B it was used heat-polymerized acrylic resin and in group C, it was used ceramic pigment. Group E was not pigmented. After pigmentation, all specimens received a transparent heat-cured resin layer. At time point zero, all specimens were assessed by a spectrophotometer connected to a colorimeter system, and the initial data were used as the standard value. Immediately after the initial assessment, all samples were kept in a UVA irradiation chamber. The following data were taken after every 24 hours until completion of 144 hours. All colorimetric data were obtained by the reflection curves of each sample and used to calculate the color difference rate. After statistical analysis, it was concluded that the samples colored with watercolour pencil in yellow and red as well as the ceramic pigment in red showed color stability clinically acceptable during the whole experimental period. Between the two types of resin used herein, the resin no 2 showed better color stability.

Page generated in 0.0755 seconds