• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de método para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se em sangue por espectrometria de massas com fonte de plasma acoplado indutivamente (ICP-MS) utilizando diluição das amostras em meio alcalino / Development of a high-throughput method for assessment of Ag, As, Cd, Co, Mn, Ni, Pb and Se in blood samples by inductively coupled plasma mass spectrometry (ICP-MS)

Nunes, Juliana Andrade 07 August 2009 (has links)
A técnica analítica mais utilizada para o monitoramento de exposição a metais tóxicos ou para avaliação de deficiência a elementos essenciais é a espectrometria de absorção atômica chama (FAAS) ou com forno de grafite (GF AAS). Entretanto, cada vez mais os laboratórios de pesquisa na área clínica estão mudando seus métodos de análise, baseados nestas técnicas, para a utilização da espectrometria de massas com plasma acoplado (ICP-MS). Isso vem acontecendo porque o ICP-MS permite a determinação de elementos químicos, em diversas matrizes, numa ampla faixa de concentração (ng L-1 a mg L-1), além de possibilitar alta rapidez de análise, capacidade multielementar e limites de detecção menores que outras técnicas analíticas. Uma das principais características do método a ser utilizado para a análise de elementos químicos em rotina por ICP-MS é que ele seja rápido, com o mínimo de manipulação da amostra. Neste sentido, métodos que propõem a análise direta de amostra são mais atrativos. Todavia, ainda é limitado o número de métodos que propõem análise direta de fluidos biológicos por ICP-MS. Neste sentido, o presente trabalho teve como objetivo o desenvolvimento de um método para análise direta de sangue por ICP-MS para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se. Para isso, amostras de sangue (200 µL) foram misturadas com 500 µL de hidróxido de tetrametilamônio (TMAH) (10% v/v) e incubadas por 10 minutos. Posteriormente, a solução resultante foi diluída para 10 mL com uma solução contendo 0,05% m/v EDTA; 0,005% v/v Triton® X-100. Em seguida, as amostras foram analisadas diretamente por ICP-MS (ELAN DRC II). Ródio (Rh) foi usado como padrão interno e a calibração das amostras foi feita por meio de ajuste de matriz com sangue base ovino. Os limites de detecção (LD) do método foram de 0,008; 0,02; 0,004; 0,009; 0,003; 0,09; 0,04; 0,1 µg L-1 para Ag, As, Cd, Co, Mn, Ni, Pb and Se, respectivamente. A validação dos resultados foi realizada com análise de um material de referência de sangue do Programa de Proficiência do Institut National de Santé Publique du Quebec, no Canadá. Validação adicional foi obtida pela comparação dos resultados obtidos pela análise de 20 amostras de sangue pelo método proposto e pela técnica de GF AAS. O método foi também comparado a outros dois existentes na literatura e comumente utilizados em laboratórios dos Estados Unidos e Suécia, apresentando limites de detecção comparáveis ou melhores e melhores exatidão e precisão. / The most used analytical technique for monitoring the exposure to toxic metals or for the assessment of the deficiency of essentials elements is the atomic absorption spectrometry with flame (FAAS) or graphite furnace (GF AAS). However, more and more clinical laboratories are changing their methods of analysis, based on this technique, to methods using inductively coupled plasma-mass spectrometry (ICP-MS). It occurs because ICP-MS allows the determination of chemical elements in various types of samples, at concentrations in a wide linear range (ng L-1 to mg L-1), providing high-throughput analysis with multielemental capability with lower detection limits. However, for routine porpuses the method of choice must be fast with minimal sample manipulation.On the other hand, the number of methods proposing direct introduction of biological fluids to the ICP-MS are still limited. This work aimed the development of a method for the direct analysis of blood samples by ICP-MS for the determination of Ag, As, Cd, Co, Mn, Ni, Pb and Se. For this, blood samples (200 L) were mixed with 500 L of tetramethylammonium hydroxide (TMAH) (10% v/v) and left at room temperature during 10 minutes. Subsequently, the resulting solution was diluted to 10 mL with a solution containing 0.05% m/v EDTA + 0005% v / v Triton ® X-100. Thus the samples were analyzed directly by ICP-MS (ELAN DRC II). Rhodium (Rh) was used as internal standard with matrix matching calibration. The method detection limits were: 0.008, 0.02, 0.004, 0.009, 0.003, 0.09, 0.04, 0.1 µg L-1 for Ag, As, Cd, Co, Mn, Ni , Pb, and Se respectively. Method validation was acquired with the analysis of blood reference material provided by the Institut National de Santé Publique du Quebec, Canada. Furthermore, for additional validation 20 ordinary blood samples were analyzed by the proposed method and by GF AAS. The method was also compared with two existing methods in the literature and commonly used in laboratories in the United States and Sweden where comparable or better detection limits and better accuracy and precision were obtained.
2

Desenvolvimento de método para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se em sangue por espectrometria de massas com fonte de plasma acoplado indutivamente (ICP-MS) utilizando diluição das amostras em meio alcalino / Development of a high-throughput method for assessment of Ag, As, Cd, Co, Mn, Ni, Pb and Se in blood samples by inductively coupled plasma mass spectrometry (ICP-MS)

Juliana Andrade Nunes 07 August 2009 (has links)
A técnica analítica mais utilizada para o monitoramento de exposição a metais tóxicos ou para avaliação de deficiência a elementos essenciais é a espectrometria de absorção atômica chama (FAAS) ou com forno de grafite (GF AAS). Entretanto, cada vez mais os laboratórios de pesquisa na área clínica estão mudando seus métodos de análise, baseados nestas técnicas, para a utilização da espectrometria de massas com plasma acoplado (ICP-MS). Isso vem acontecendo porque o ICP-MS permite a determinação de elementos químicos, em diversas matrizes, numa ampla faixa de concentração (ng L-1 a mg L-1), além de possibilitar alta rapidez de análise, capacidade multielementar e limites de detecção menores que outras técnicas analíticas. Uma das principais características do método a ser utilizado para a análise de elementos químicos em rotina por ICP-MS é que ele seja rápido, com o mínimo de manipulação da amostra. Neste sentido, métodos que propõem a análise direta de amostra são mais atrativos. Todavia, ainda é limitado o número de métodos que propõem análise direta de fluidos biológicos por ICP-MS. Neste sentido, o presente trabalho teve como objetivo o desenvolvimento de um método para análise direta de sangue por ICP-MS para determinação de Ag, As, Cd, Co, Mn, Ni, Pb e Se. Para isso, amostras de sangue (200 µL) foram misturadas com 500 µL de hidróxido de tetrametilamônio (TMAH) (10% v/v) e incubadas por 10 minutos. Posteriormente, a solução resultante foi diluída para 10 mL com uma solução contendo 0,05% m/v EDTA; 0,005% v/v Triton® X-100. Em seguida, as amostras foram analisadas diretamente por ICP-MS (ELAN DRC II). Ródio (Rh) foi usado como padrão interno e a calibração das amostras foi feita por meio de ajuste de matriz com sangue base ovino. Os limites de detecção (LD) do método foram de 0,008; 0,02; 0,004; 0,009; 0,003; 0,09; 0,04; 0,1 µg L-1 para Ag, As, Cd, Co, Mn, Ni, Pb and Se, respectivamente. A validação dos resultados foi realizada com análise de um material de referência de sangue do Programa de Proficiência do Institut National de Santé Publique du Quebec, no Canadá. Validação adicional foi obtida pela comparação dos resultados obtidos pela análise de 20 amostras de sangue pelo método proposto e pela técnica de GF AAS. O método foi também comparado a outros dois existentes na literatura e comumente utilizados em laboratórios dos Estados Unidos e Suécia, apresentando limites de detecção comparáveis ou melhores e melhores exatidão e precisão. / The most used analytical technique for monitoring the exposure to toxic metals or for the assessment of the deficiency of essentials elements is the atomic absorption spectrometry with flame (FAAS) or graphite furnace (GF AAS). However, more and more clinical laboratories are changing their methods of analysis, based on this technique, to methods using inductively coupled plasma-mass spectrometry (ICP-MS). It occurs because ICP-MS allows the determination of chemical elements in various types of samples, at concentrations in a wide linear range (ng L-1 to mg L-1), providing high-throughput analysis with multielemental capability with lower detection limits. However, for routine porpuses the method of choice must be fast with minimal sample manipulation.On the other hand, the number of methods proposing direct introduction of biological fluids to the ICP-MS are still limited. This work aimed the development of a method for the direct analysis of blood samples by ICP-MS for the determination of Ag, As, Cd, Co, Mn, Ni, Pb and Se. For this, blood samples (200 L) were mixed with 500 L of tetramethylammonium hydroxide (TMAH) (10% v/v) and left at room temperature during 10 minutes. Subsequently, the resulting solution was diluted to 10 mL with a solution containing 0.05% m/v EDTA + 0005% v / v Triton ® X-100. Thus the samples were analyzed directly by ICP-MS (ELAN DRC II). Rhodium (Rh) was used as internal standard with matrix matching calibration. The method detection limits were: 0.008, 0.02, 0.004, 0.009, 0.003, 0.09, 0.04, 0.1 µg L-1 for Ag, As, Cd, Co, Mn, Ni , Pb, and Se respectively. Method validation was acquired with the analysis of blood reference material provided by the Institut National de Santé Publique du Quebec, Canada. Furthermore, for additional validation 20 ordinary blood samples were analyzed by the proposed method and by GF AAS. The method was also compared with two existing methods in the literature and commonly used in laboratories in the United States and Sweden where comparable or better detection limits and better accuracy and precision were obtained.

Page generated in 0.0793 seconds