• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Medida absoluta da atividade e determinação da probalidade de emissão gama por decaimento do 177 Lu / Absolute activity measurement and determination of gamma-ray emission probability per decay of 177Lu

Silva, Fabricio Fernandes Vaz da 17 February 2011 (has links)
O presente trabalho teve como objetivo a padronização em atividade do radionuclídeo 177Lu, um importante radiofármaco utilizado no tratamento de câncer neuroendócrino. Este radionuclídeo se desintegra por emissão beta acompanhada de várias emissões gama simultâneas, o que tornou possível a aplicação do método de coincidência 4πβ-γ. Para a detecção da radiação beta, foi utilizado um detector proporcional (PC), com geometria 4π e dois cintiladores de NaI(Tl) para a detecção da radiação gama. Os sinais gerados nos detectores passaram por amplificadores, discriminadores e módulos atrasadores, para serem enviados a um analisador multicanal. Para este experimento, foi utilizado um sistema de coincidências que aplica um módulo TAC (Time to Amplitude Converter), o qual converte diferença de tempo em amplitude de pulso. Para obter-se a variação na eficiência beta, foram acrescentados absorvedores de Collodion nas partes superior e inferior da fonte radioativa. Desta forma, foi possível extrapolar o valor para eficiência beta igual a 100%, obtendo assim a atividade da fonte radioativa. A curva de extrapolação experimental foi comparada com a previsão teórica, obtida por meio do método de Monte Carlo. Além da padronização em atividade do 177Lu, também foram determinadas as suas probabilidades de emissão gama por decaimento para cada uma das principais transições gama, por meio de um espectrômetro de HPGe, previamente calibrado. / The present work aimed the activity standardization of radionuclide 177Lu, an important radioisotope used for treatment of neuroendocrine cancer. This radionuclide disintegrates by beta decay followed by several simultaneous gamma-ray emissions, which made possible the application of the 4πβ-γ coincidence method. For the detection of beta radiation in 4π geometry a proportional detector (PC) was used, and for gamma radiation detection a pair of NaI(Tl) scintillators was used. The signals generated by the detectors passed through amplifiers, discriminators and delay modules, and were sent to a multichannel analyzer. For the present experiment, the system includes a TAC (Time to Amplitude Converter) module which converts the time difference in pulse amplitude. To obtain the variation in beta efficiency, Collodion absorbers at the top and bottom of the radioactive source were applied. In this way, it was possible to extrapolate the beta efficiency value to 100%, thereby obtaining the radioactive source activity. The extrapolated experimental curve was compared with the theoretical prediction, obtained by means of the Monte Carlo method. Besides the activity standardization of 177Lu, its gamma-ray emission probabilities per decay for the main gamma transitions were also determined by means of an HPGe spectrometer, previously calibrated.
2

Medida absoluta da atividade e determinação da probalidade de emissão gama por decaimento do 177 Lu / Absolute activity measurement and determination of gamma-ray emission probability per decay of 177Lu

Fabricio Fernandes Vaz da Silva 17 February 2011 (has links)
O presente trabalho teve como objetivo a padronização em atividade do radionuclídeo 177Lu, um importante radiofármaco utilizado no tratamento de câncer neuroendócrino. Este radionuclídeo se desintegra por emissão beta acompanhada de várias emissões gama simultâneas, o que tornou possível a aplicação do método de coincidência 4πβ-γ. Para a detecção da radiação beta, foi utilizado um detector proporcional (PC), com geometria 4π e dois cintiladores de NaI(Tl) para a detecção da radiação gama. Os sinais gerados nos detectores passaram por amplificadores, discriminadores e módulos atrasadores, para serem enviados a um analisador multicanal. Para este experimento, foi utilizado um sistema de coincidências que aplica um módulo TAC (Time to Amplitude Converter), o qual converte diferença de tempo em amplitude de pulso. Para obter-se a variação na eficiência beta, foram acrescentados absorvedores de Collodion nas partes superior e inferior da fonte radioativa. Desta forma, foi possível extrapolar o valor para eficiência beta igual a 100%, obtendo assim a atividade da fonte radioativa. A curva de extrapolação experimental foi comparada com a previsão teórica, obtida por meio do método de Monte Carlo. Além da padronização em atividade do 177Lu, também foram determinadas as suas probabilidades de emissão gama por decaimento para cada uma das principais transições gama, por meio de um espectrômetro de HPGe, previamente calibrado. / The present work aimed the activity standardization of radionuclide 177Lu, an important radioisotope used for treatment of neuroendocrine cancer. This radionuclide disintegrates by beta decay followed by several simultaneous gamma-ray emissions, which made possible the application of the 4πβ-γ coincidence method. For the detection of beta radiation in 4π geometry a proportional detector (PC) was used, and for gamma radiation detection a pair of NaI(Tl) scintillators was used. The signals generated by the detectors passed through amplifiers, discriminators and delay modules, and were sent to a multichannel analyzer. For the present experiment, the system includes a TAC (Time to Amplitude Converter) module which converts the time difference in pulse amplitude. To obtain the variation in beta efficiency, Collodion absorbers at the top and bottom of the radioactive source were applied. In this way, it was possible to extrapolate the beta efficiency value to 100%, thereby obtaining the radioactive source activity. The extrapolated experimental curve was compared with the theoretical prediction, obtained by means of the Monte Carlo method. Besides the activity standardization of 177Lu, its gamma-ray emission probabilities per decay for the main gamma transitions were also determined by means of an HPGe spectrometer, previously calibrated.
3

Padronização em sistema primário por coincidências 4πβ-γ e determinação das intensidades de emissão gama por decaimento dos radionuclídeos Cu-64 e Ho-166 / Primary standardization of 64Cu and 166Ho radionuclides in the 4πβ(PC)-γ coincidence system and determination of its gamma-ray emission probability per decay

Yamazaki, Ione Makiko 12 February 2019 (has links)
O Laboratório de Metrologia Nuclear (LMN) do Instituto de Pesquisas Energéticas e Nucleares (IPEN) realizou a padronização primária dos radionuclídeos 64Cu e 166Ho. Esses radioisótopos são utilizados na Medicina Nuclear em investigações diagnósticas e em radioterapia. A atividade absoluta foi determinada utilizando o método de coincidências 4πβ(PC)- γ associado à técnica de extrapolação de eficiência. Para isto, foram utilizados um contador proporcional em geometria 4π acoplado ao um contador de cintilação NaI (Tl). Para a padronização do 64Cu foram utilizados dois sistemas para registro de dados: sistema TAC e sistema SCS. No sistema TAC é utilizado o módulo Time to Amplitude Converter (TAC) associado a um analisador multicanal, sendo que a eficiência do detector 4πPC foi variada por meio de absorvedores externos e foi aplicado fator de correção para as eficiências beta denominado fator Kawada. No sistema SCS (Software Coincidence System) o registro dos eventos foi feito por meio da digitalização dos pulsos, a eficiência do detector 4πPC foi variada por discriminação eletrônica e a atividade foi obtida pela extrapolação biparamétrica. A padronização do 166Ho em sistema de coincidências 4πβ(PC)- γ foi realizada utilizando o sistema de aquisição de dados por software, SCS (Software Coincidence System). Para determinação das probabilidade de emissão gama dos radionuclídeos foi utilizado um espectrômetro gama HPGe calibrado com ampolas padrão de 152Eu, 60Co, 133Ba, 137Cs e 241Am, calibradas no sistema primário 4πβ(PC)- γ. A probabilidade de emissão gama por decaimento do fóton de 1345,7 keV do 64Cu obtida foi de 0,472 (10) % apresentando um bom acordo com os dados da literatura. A probabilidade de emissão gama por decaimento do fóton gama de 1379,45 keV do 166Ho foi de 0,936 (4) %. Por meio destas medidas foi possível também a determinação das intensidades relativas de outros fótons emitidos por este radionuclídeo. Os resultados obtidos foram concordantes com a literatura dentro da incerteza experimental. / The procedure followed by the Nuclear Metrology Laboratory (LMN) at the Nuclear and Energy Research Institute (IPEN) for the primary standardization of 64Cu and 166Ho is described. These radionuclides are widely applied to Nuclear Medicine such as in diagnostic investigations and in radiotherapy. The absolute activity of both radionuclides were determined by the efficiency extrapolation method applied to 4πβ(PC)-γ coincidence counting system using a proportional counter in 4π geometry coupled with NaI(Tl) scintillation counter. The primary standardisation of 64Cu for the conventional coincidence counting, the events were registered using a Time to Amplitude Converter (TAC) system associated with a multi-channel analyzer and by a software coincidence counting system, SCS, a digital method for primary activity measurements that simplifies the setting of optimal coincidence parameters. For perfoming the standardization of 64Cu in the TAC system, the efficiency of the 4πβ(PC)-γ detector was varied using external absorbers and in order to correct the beta efficiency, the Kawada factor was applied. In the SCS counting, the events were registered by means of pulse digitalization and the efficiencies (εEC and εβ) were varied through eletronic discrimination. The biparametric method was used for determining the absolute activity and the result was in good agreement with the ones obtained with TAC system. The standardization of 166Ho in the primary system was performed using the software coincidence counting, SCS. The gamma-ray emission probability per decay of the main transitions of both radionuclides were determined using the results obtained from the primary method, the 4πβ(PC)-γ coincidence system, associated with a calibrated HPGe gamma-ray spectrometer with standard ampoules of 152Eu, 60Co, 133Ba, 137Cs e 241Am, previously standardized in the 4πβ(PC)-γ system. The gamma-ray emission probability per decay of the 1345,7 keV transition of 64Cu was 0,472 (10) %, in good agreement with the literature. The gamma-ray emission probability per decay of the 1379,45 keV transition of 166Ho was 0,936 (4) %. It were also determined the relative gamma ray emmission probability of other gamma rays for this nuclide . All the results obtained were in good agreement with the literature.

Page generated in 0.0987 seconds