• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Protusão de ombros: construção de aparelho postural de biofeedback / Shoulder protrusion: construction of a postural biofeedback device

Carvalho, Gilmar José Alves de 29 March 2010 (has links)
Made available in DSpace on 2016-12-06T17:07:27Z (GMT). No. of bitstreams: 1 Gilmar.pdf: 1680429 bytes, checksum: 6eb062d33cfa1169c08c1dc12e076ae5 (MD5) Previous issue date: 2010-03-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study is to construct a biofeedback device to monitor the posture of shoulder protrusion. The research subjects were five normal adult individuals. The choice was intentional, with one being male and four female, with an average age of 26.6 years (20/326). A device was built to detect posture of the shoulder protrusion by means of sensors with gyroscopes fixed to the acromia. Based on a pre-established posture, the device detects variations in the coordinates. When the individual transgresses from the pre-established posture the device issues a vibratory alert signal by biofeedback. This device was tested in a laboratory and in the field. In the laboratory the vibratory response was checked in the movements of clavicular abduction and trunk rotation movements in different angular positions. The vibratory response was also found at pre-established times that represented tolerance of activation in relation to daily activities. In the laboratory, all of these measures of the device functions were virtually simulated with the Proteus Labcenter Electronics software. In the field, in working activities, the viability of the use of the device was verified when programmed with a tolerance of 30 seconds and allowing a variation of 7 degrees in clavicular abduction. The laboratory tests for validation demonstrated that the precision of the coordinate measurements is <1°. The coefficients of correlation of the tests and retests were = 1. The results measured in the tests show that this device measures what it was proposed to measure and can be used in the detection and orientation of posture of shoulder protrusion. / Este estudo teve como objetivo a construção de um aparelho de biofeedback para a monitoração da postura de protusão de ombros. Os sujeitos da pesquisa foram cinco indivíduos adultos normais. A escolha foi intencional, sendo um do gênero masculino e quatro femininos, média de idade = 26,6 anos (20/326). Foi desenvolvido um aparelho de detecção da postura de protusão de ombros por meio de sensores com giroscópios fixados nos acrômios. A partir de uma postura pré-estabelecida o aparelho detecta as variações de coordenadas. Quando o indivíduo transgride a postura pré-estabelecida o aparelho emite por biofeedback um sinal de alerta vibratório. Este aparelho foi testado em laboratório e em campo. Em laboratório foi aferida a resposta de vibração nos movimentos de adução clavicular e rotação de tronco em diferentes posições angulares. Também foi verificada a resposta de vibração em tempos pré-estabelecidos que representam a tolerância de ativação frente as atividades de vida diária. Em laboratório, todos estes aferimentos de funções do aparelho foram simulados virtualmente no software Proteus Labcenter Eletronics. Em campo, em atividades laborais, foi verificada a viabilidade de uso do aparelho programado com um tempo de tolerância de 30s e permitindo a variação de 7° graus de movimento de adução clavicular. Os testes de validação de laboratório demonstraram que a precisão das medidas de coordenadas do aparelho é <1°. Os coeficientes de correlação dos testes e retestes foram =1. Os resultados aferidos nos testes mostraram que este aparelho mede o que se propõe a medir e pode ser utilizado na detecção e orientação na postura de protusão de ombros.

Page generated in 0.0511 seconds