• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 1
  • 1
  • Tagged with
  • 21
  • 21
  • 21
  • 11
  • 7
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Gaseous discharges and their applications as high power plasma switches

Sözer, Esin Bengisu, Kirkici, Hulya, January 2008 (has links) (PDF)
Thesis (M.S.)--Auburn University, 2008. / Abstract. Vita. Includes bibliographical references (p. 55-57).
12

Development and optimisation of a solid-state pulsed power supply for a CO₂ TEA laser

Stehmann, Timo 12 1900 (has links)
Thesis (MSc)--Stellenbosch University, 2003. / ENGLISH ABSTRACT: With technological advances in solid-state switches the modernization of conventional pulsed power supplies utilizing thyratrons has become possible. A novel pulsed power supply is designed where two series-stacked IGBTs (rated at 1700 V and 300 A each) are used to replace a thryatrondriven pulsed power supply for a mini CO2 TEA laser. The mini CO2 TEA laser is firstly characterized in order to optimize the design of the pulsed power supply. It is found that stable laser discharges can be obtained with electrode voltage rise-times of 150 ns or less. Furthermore, the optical output energy and the efficiency of the laser have been significantly increased by reducing the peaking capacitor size of the pulsed power supply. The two stacked IGBTs switch a C-C transfer loop and the generated pulse is stepped up by a pulse transformer and is compressed by a two-stage magnetic pulse compression unit. Theoretically and through measurements it is shown that automatic voltage sharing between the two IGBTs can be obtained if the turn-on time of the IGBTs is much faster than the transfer time of the switched C-C transfer loop. Lifetime tests reveal that high-power IGBTs are able to reliably switch pulses with peak currents between 4 and 5 times the rated average current of the device. Under laser fault conditions, i.e. laser arcing or missing laser discharges, the reliability of the pulser can be increased by using over-voltage snubbers. In addition, it was found that the internal diode of IGBT modules can eventually fail under the prevalence of laser fault conditions. A modular construction approach is used where components of the pulsed power supply are preassembled. A new rectangular layout of the magnetic pulse compression unit is utilized in order to minimize size and simplify the final construction and assembly. / AFRIKAANSE OPSOMMING: Nuwe ontwikkeling in vastetoestand-skakelaars het die modernisering van laser-pulskragbronne moontlik gemaak. ’n Nuwe kragbron wat gebruik maak van twee seriegeskakelde IGBT’s is ontwerp om ’n Tiratron-gedrewe laserkragbron te vervang, wat vir ’n mini-C02-TEA-laser gebruik word. Die laser is vooraf eers gekarakteriseer om sodoende die laserkragbron te optimeer. Daar is bevind dat stabiele laserontladings verkry kan word met spanningstygtye van 150 ns of minder. Verder kan die uittree-energie van die laser beduidend verhoog word deur die uittreekapasitore (eng.: peaking capacitors) van die laserkragbron te verminder. Die twee serie-geskakelde IGBT’s skakel ’n C-C oordraglus. Die spanning van die gegenereerde puls word deur ’n pulstransformator verhoog en die stygtyd van die puls word met ’n twee-stadium magnetiese pulskompressor verlaag. Teoreties en deur metings kan getoon word dat eweredige spanningsverdeling tussen die twee IGBT’s outomaties verkry kan word indien die skakeltye van die IGBT’s baie vinniger as die oordragstyd van die C-C oordraglus is. Toetse het getoon dat IGBT’s pulse met piekstrome van tussen vier tot vyf keer die gespesifiseerde gemiddelde stroom betroubaar kan skakel. Tydens laserfouttoestande kan die betroubaarheid van die IGBT verhoog word deur oorspanningsgapsers te gebruik, maar onder fouttoestande wat voortduur, kan die IGBT se interne diode vemietig word. Die komponente van die laserkragbron is as modules vervaardig, wat op ’n maklike wyse gemonteer kan word. ’n Nuwe reghoekige uitleg is gebruik vir die konstruksie van die magnetiese pulskompressor, waarmee die grootte van die pulskompressor geminimeer en die konstruksie vergemaklik is.
13

Electromechanical Modeling and Open-Loop Control of Parallel-Plate Pulsed Plasma Microthrusters with Applied Magnetic Fields

Laperriere, David Daniel 26 June 2005 (has links)
"The pulsed plasma thruster (PPT) is an onboard electromagnetic propulsion device currently being considered for use in various small satellite missions. The work presented in this thesis is directed toward improving PPT performance using a control engineering approach along with externally applied magnetic fields. An improved one dimensional electromechanical model for PPT operation is developed. This slug model represents the PPT as an LRC circuit with a dynamics equation for the ablated plasma. The improved model includes detailed derivation for the induced magnetic field and a model for the plasma resistance. A modified electromechanical model for the case of externally applied magnetic fields is also derived for the parallel plate geometry. A software package with a graphical user interface (GUI) is developed for the simulation of various PPT types, geometric configurations, and parameters The simulations show excellent agreement with data from the Lincoln Experimental Satellite (LES)-6, the LES-8/9 PPT and the Univ. of Tokyo PPT. The control objective employed in this thesis involves the maximization of the specific impulse and thrust efficiency of the PPT, which are each directly related with the exhaust velocity of the thruster. This objective is achieved through the use of an externally applied magnetic field as a system actuator. To simulate an open-loop constant-input controller the modified electromechanical PPT model is applied to the various PPT configurations. In this controller the external magnetic field was applied as constant throughout or portions of the PPT channel. For the Univ. of Tokyo PPT a magnetic field applied over the entire 6-cm long channel increases the specific impulse and thrust efficiency by 10% over the case that the filed is applied in the first 1.75 cm of the PPT channel. The magnitude of these increases compare well with the results of the UOT applied B-field experiments. For the LES-6 and LES-9 PPTs, the simulations predicts significant performance enhancements with approximately linear increases for the specific impulse, thrust efficiency and impulse bit. "
14

Langmuir Probe Measurements in the Plume of a Pulsed Plasma Thruster

Eckman, Robert Francis 04 October 1999 (has links)
"As new, smaller satellites are built, the need for improved on-board propulsion systems has grown. The pulsed plasma thruster has received attention due to its low power requirements, its simple propellant management, and the success of initial flight tests. Successful integration of PPTs on spacecraft requires the comprehensive evaluation of possible plume-spacecraft interactions. The PPT plume consists of neutrals and ions from the decomposition of the Teflon propellant, material from electrode erosion, as well as electromagnetic fields and optical emissions. To investigate the PPT plume, an on-going program is underway at WPI that combines experimental and computational investigations. Experimental investigation of the PPT plume is challenging due to the unsteady, pulsed as well as the partially ionized character of the plume. In this thesis, a triple Langmuir probe apparatus was designed and used to obtain electron temperature and density measurements in the plume of a PPT. This experimental investigation provides further characterization of the plume, much needed validation data for computational models, and is useful in thruster optimization studies. The pulsed plasma thruster used in this study is a rectangular geometry laboratory model built at NASA Lewis Research Center for component lifetime tests and plume studies. It is almost identical in size and performance to the LES 8/9 thruster, ablating 26.6 ug of Teflon, producing an impulse bit of 256 uN-s and a specific impulse of 986 s at 20 J. All experiments were carried out at NASA LeRC Electric Propulsion Laboratory. The experimental setup included triple Langmuir probes mounted on a moveable probe stand, to collect data over a wide range of locations and operating conditions. Triple probes have the ability to instantaneously measure electron temperature and density, and have the benefit of being relatively simple to use, compared to other methods used to measure these same properties. The implementation of this measuring technique is discussed in detail, to aid future work that utilizes these devices. Electron temperature and density was measured from up to 45 degrees from the centerline on planes parallel and perpendicular to the thruster electrodes, for thruster energy levels of 5, 20 and 40 J. Radial distances extend from 6 to 20 cm downstream from the Teflon surface. These locations cover the core of the PPT plume, over a range of energy levels that corresponds to proposed mission operating conditions. Data analysis shows the spatial and temporal variation of the plume. Maximum electron density near the exit of the thruster is 1.6 x 1020, 1.6 x 1021, and 1.8 x 1021 m-3 for the 5, 20 and 40 J discharges, respectively. At 20 cm downstream from the Teflon surface, densities are 1 x 1019, 1.5 x 1020 and 4.2 x 1020 for the 5, 20 and 40 J discharges, respectively. The average electron temperature at maximum density was found to vary between 3.75 and 4.0 eV for the above density measurements at the thruster exit, and 20 cm from the Teflon surface the temperatures are 0.5, 2.5, and 3 eV for the 5, 20 and 40 J discharges. Plume properties show a great degree of angular variation in the perpendicular plane and very little in the parallel plane, most likely due to the rectangular geometry of the PPT electrodes. Simultaneous electron temperature and density traces for a single thruster discharge show that the hottest electrons populate the leading edge of the plume. Analysis between pulses shows a 50% variation in density and a 25% variation in electron temperature. Error analysis estimates that maximum uncertainty in the temperature measurements to be approximately +/- 0.75 eV due to noise smoothing, and the maximum uncertainty in electron density to be +/- 60%, due to assumptions related to the triple probe theory. In addition, analysis of previously observed slow and fast ion components in the PPT plume was performed. The analysis shows that there is approximately a 3 us difference in creation time between the fast and slow ions, and that this correlates almost exactly with the half period of the oscillations in the thruster discharge current."
15

Implementation of the University of Missouri Terawatt Test Stand and the study of a large, multichanneling, laser tirggered gas switch

LeChien, Keith Robert, January 2006 (has links)
Thesis (Ph.D.)--University of Missouri-Columbia, 2006. / The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file viewed on (February 27, 2007) Vita. Includes bibliographical references.
16

Flashover prevention on polystyrene high voltage insulators in a vacuum

Benwell, Andrew L., January 2007 (has links)
Thesis (M.S.)--University of Missouri-Columbia, 2007. / The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file (viewed on March 18, 2008) Includes bibliographical references.
17

Runtime and jitter of a laser triggered gas switch

Hutsel, Brian T. Kovaleski, Scott D. January 2008 (has links)
The entire thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file; a non-technical public abstract appears in the public.pdf file. Title from PDF of title page (University of Missouri--Columbia, viewed on September 24, 2009). Thesis advisor: Dr. Scott Kovaleski. Includes bibliographical references.
18

Investigation of a Pulsed Plasma Thruster Plume Using a Quadruple Langmuir Probe Technique

Zwahlen, Jurg C 08 January 2003 (has links)
The rectangular pulsed plasma thruster (PPT) is an electromagnetic thruster that ablates Teflon propellant to produce thrust in a discharge that lasts 5-20 microseconds. In order to integrate PPTs onto spacecraft, it is necessary to investigate possible thruster plume-spacecraft interactions. The PPT plume consists of neutral and charged particles from the ablation of the Teflon fuel bar as well as electrode materials. In this thesis a novel application of quadruple Langmuir probes is implemented in the PPT plume to obtain electron temperature, electron density, and ion speed ratio measurements (ion speed divided by most probable thermal speed). The pulsed plasma thruster used is a NASA Glenn laboratory model based on the LES 8/9 series of PPTs, and is similar in design to the Earth Observing-1 satellite PPT. At the 20 J discharge energy level, the thruster ablates 26.6 mg of Teflon, creating an impulse bit of 256 mN-s with a specific impulse of 986 s. The quadruple probes were operated in the so-called current mode, eliminating the need to make voltage measurements. The current collection to the parallel to the flow electrodes is based on Laframboise's theory for probe to Debye length ratios between 5 and 100, and on the thin-sheath theory for ratios above 100. The ion current to the perpendicular probe is based on a model by Kanal and is a function of the ion speed ratio, the applied non-dimensional potential and the collection area. A formal error analysis is performed using the complete set of nonlinear current collection equations. The quadruple Langmuir probes were mounted on a computer controlled motion system that allowed movement in the radial direction, and the thruster was mounted on a motion system that allowed angular variation. Measurements were taken at 10, 15 and 20 cm form the Teflon fuel bar face, at angles up to 40 degrees off of the centerline axis at discharge energy levels of 5, 20, and 40 J. All data points are based on an average of four PPT pulses. Data analysis shows the temporal and spatial variation in the plume. Electron temperatures show two peaks during the length of the pulse, a trend most evident during the 20 J and 40 J discharge energies at 10 cm from the surface of the Teflon fuel bar. The electron temperatures after the initial high temperature peak are below 2 eV. Electron densities are highest near the thruster exit plane. At 10 cm from the Teflon surface, maximum electron densities are 1.04e20 ± 2.8e19 m-3, 9.8e20 ± 2.3e20 m-3, and 1.38e21 ± 4.05e20 m-3 for the 5 J, 20 J and 40 J discharge energy, respectively. The electrons densities decrease to 2.8x1019 ± 8.9e18 m-3, 1.2e20 ± 4.2e19 m-3, and 4.5e20 ± 1.2e20 m-3 at 20 cm for the 5 J, 20 J, and 40 J cases, respectively. Electron temperature and density decrease with increasing angle away from the centerline, and with increasing downstream distance. The plume is more symmetric in the parallel plane than in the perpendicular plane. Ion speed ratios are lowest near the thruster exit, increase with increasing downstream distance, but do not show any consistent angular variation. Peak speed ratios at a radial distance of 10 cm are 5.9±3.6, 5.3±0.39, and 4.8±0.41 for the 5 J, 20 J and 40 J discharge energies, respectively. The ratios increase to 6.05±5.9, 7.5±1.6, and 6.09±0.72 at a radial distance of 20 cm. Estimates of ion velocities show peak values between 36 km/s to 40 km/s, 26 km/s to 30 km/s, and 26 km/s to 36 km/s for the % J, 20 J, and 40 J discharge energies, respectively.
19

Energy storage system requirements for shipboard power systems supplying pulsed power loads

Duvoor, Prashanth, January 2007 (has links)
Thesis (M.S.)--Mississippi State University. Department of Electrical and Computer Engineering. / Title from title screen. Includes bibliographical references.
20

Langmuir Probe Measurements in the Plume of a Pulsed Plasma Thruster

Byrne, Lawrence Thomas 19 December 2002 (has links)
"The ablative Teflon pulsed plasma thruster (PPT) is an onboard electromagnetic propulsion enabling technology for small spacecraft missions. The integration of PPTs onboard spacecraft requires the understanding and evaluation of possible thruster/spacecraft interactions. To aid in this effort the work presented in this thesis is directed towards the development and application of Langmuir probe techniques for use in the plume of PPTs. Double and triple Langmuir probes were developed and used to measure electron temperature and density of the PPT plume. The PPT used in this thesis was a laboratory model parallel plate ablative Teflon® PPT similar in size to the Earth Observing (EO-1) PPT operating in discharge energies between 5 and 40 Joules. The triple Langmuir probe was operated in the current-mode technique that requires biasing all three electrodes and measuring the resulting probe currents. This new implementation differs from the traditional voltage-mode technique that keeps one probe floating and requires a voltage measurement that is often susceptible to noise in the fluctuating PPT plume environment. The triple Langmuir probe theory developed in this work incorporates Laframboise’s current collection model for Debye length to probe radius ratios less than 100 in order to account for sheath expansion effects on ion collection, and incorporates the thin-sheath current collection model for Debye length to probe radius ratios greater than 100. Error analysis of the non-linear system of current collection equations that describe the operation of the current-mode triple Langmuir probe is performed as well. Measurements were taken at three radial locations, 5, 10, and 15 cm from the Teflon® surface of the PPT and at angles of 20 and 40 degrees to either side of the thruster centerline as well as at the centerline. These measurements were taken on two orthogonal planes, parallel and perpendicular to the PPT electrodes. A data-processing software was developed and implements the current-mode triple Langmuir probe theory and associated error analysis. Results show the time evolution of the electron temperature and density. Characteristic to all the data is the presence of hot electrons of approximately 5 to 10 eV at the beginning of the pulse, occurring near the peak of the discharge current. The electron temperature quickly drops off from its peak values to 1-2 eV for the remainder of the pulse. Peak electron densities occur after the peak temperatures. The maximum electron density values on the centerline of the plume of a laboratory PPT 10 cm from the Teflon® surface are 6.6x10^19 +/- 1.3x10^19 m^-3 for the 5 J PPT, 7.2x10^20 +/- 1.4x10^20 m^-3 for the 20 J PPT, and 1.2x10^21 +/- 2.7x10^20 m^-3 for the 40 J PPT. Results from the double Langmuir probe taken at r=10 cm, theta perpendicular=70 degrees and 90 degrees of a laboratory PPT showed good agreement with the triple probe method."

Page generated in 0.174 seconds