• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da variação da densidade mamográfica ao longo de um ciclo menstrual. / Study of variation of the mammographic density during an menstrual cicle.

Pazuello, Kíssiner 08 April 2003 (has links)
Há muito que se reconhece que a mama não é um orgão estático. Do nascimento à senilidade a mama esta sujeita à variações que vão desde o formato até a composição e arquitetura tecidual. Estas variações são notórias à simples inspeção, palpação, cortes histológicos, dosagens e outros métodos de estudo. Tais variações são decorrentes de fenômenos da esfera endócrina relacionada à vários hormônios envolvidos com o desenvolvimento, tal como: Estrogênios, FSH, LH, TSH, Mineralocorticóides, Prolactina, Progestágenos, Insulina , T3, T4, Glicocorticóides, Hormônio do Crescimento etc. Por outro lado, sabe se também das variações que a mama sofre dentro de apenas um ciclo menstrual decorrentes de fenômenos da esfera endócrina diretamente relacionadas aos hormônios envolvidos com o ciclo menstrual. Por isso, o presente trabalho avalia as implicações cíclicas da mama na qualidade da imagem mamográfica. Para tanto, uma investigação extensiva é feita com exposições radiográficas das mamas de uma cabra a fim de avaliar o perfil das variações de densidade ao longo de um ciclo completo. Inferências dos resultados obtidos são comparadas com algumas mamografias de mulheres , o que comprova a influência e o período em que melhor se pode visibilizar estruturas de interesse no mamograma convencional. / There is known, in long time, that breast is not an static organ. From birth to old age the breast is vulnerable to many variations that come from shape to composition and tissue architecture. This variation is well-know in a single inspection, touching, histological cuts, dosages and many others learning’s methods.These variations come from endocrine phenomenon, connected to many hormones that are involved with the breasts development, as this sequence: Estrogenes, FSH, LH, TSH, T3, T4, Glycocorticoids, Growth’s Hormones and many others. On the other hand, it’s known that the breast’s variations during a menstrual cycle come from endocrine phenomenon with a directly connection to the hormones in this cycle. The present work evaluatetes the breast cycle implications to mammographic images quality. For this pourpose, an extensive investigation is been done by using radiographic exposures of an goat breast in orden to evaluate the image density variation pattern thow a complete cycle. The result can ben inferred to some human mammographics showin the influence and period when structures of interest in convencional mammographicies.
2

Estudo da variação da densidade mamográfica ao longo de um ciclo menstrual. / Study of variation of the mammographic density during an menstrual cicle.

Kíssiner Pazuello 08 April 2003 (has links)
Há muito que se reconhece que a mama não é um orgão estático. Do nascimento à senilidade a mama esta sujeita à variações que vão desde o formato até a composição e arquitetura tecidual. Estas variações são notórias à simples inspeção, palpação, cortes histológicos, dosagens e outros métodos de estudo. Tais variações são decorrentes de fenômenos da esfera endócrina relacionada à vários hormônios envolvidos com o desenvolvimento, tal como: Estrogênios, FSH, LH, TSH, Mineralocorticóides, Prolactina, Progestágenos, Insulina , T3, T4, Glicocorticóides, Hormônio do Crescimento etc. Por outro lado, sabe se também das variações que a mama sofre dentro de apenas um ciclo menstrual decorrentes de fenômenos da esfera endócrina diretamente relacionadas aos hormônios envolvidos com o ciclo menstrual. Por isso, o presente trabalho avalia as implicações cíclicas da mama na qualidade da imagem mamográfica. Para tanto, uma investigação extensiva é feita com exposições radiográficas das mamas de uma cabra a fim de avaliar o perfil das variações de densidade ao longo de um ciclo completo. Inferências dos resultados obtidos são comparadas com algumas mamografias de mulheres , o que comprova a influência e o período em que melhor se pode visibilizar estruturas de interesse no mamograma convencional. / There is known, in long time, that breast is not an static organ. From birth to old age the breast is vulnerable to many variations that come from shape to composition and tissue architecture. This variation is well-know in a single inspection, touching, histological cuts, dosages and many others learning’s methods.These variations come from endocrine phenomenon, connected to many hormones that are involved with the breasts development, as this sequence: Estrogenes, FSH, LH, TSH, T3, T4, Glycocorticoids, Growth’s Hormones and many others. On the other hand, it’s known that the breast’s variations during a menstrual cycle come from endocrine phenomenon with a directly connection to the hormones in this cycle. The present work evaluatetes the breast cycle implications to mammographic images quality. For this pourpose, an extensive investigation is been done by using radiographic exposures of an goat breast in orden to evaluate the image density variation pattern thow a complete cycle. The result can ben inferred to some human mammographics showin the influence and period when structures of interest in convencional mammographicies.
3

Avaliação ponto a ponto de sistemas de imagem radiológica utilizando funções de espalhamento de ponto simuladas. / Evaluating the focal sopt MTF in all radiological field location by computer simulation.

Marques, Paulo Mazzoncini de Azevedo 23 September 1994 (has links)
Esta tese propõe um método de avaliação de sistemas de obtenção de imagem radiológica através das Funções de Transferência simuladas para qualquer região do campo de radiação. Esse processo de simulação reflete as mudanças sofridas pelo ponto focal e, portanto, pela Função de Espalhamento de Ponto (FEP) ao longo do campo. A avaliação utiliza informações obtidas de Funções de Transferência ótica bi-dimensionais calculadas através da aplicação de Transformadas de Fourier sobre as Funções de Espalhamento de Ponto simuladas. O método permite realizar um mapeamento da resposta em freqüências espaciais dos sistemas radio1ógicos para todo o campo de radiação, comparar a nitidez da imagem de sistemas distintos com relação a regiões equivalentes e estudar uma região especifica para prever as distorções que serão inseridas na imagem. / In this work a method of evaluation for the radiological imaging systems performance by simulated transfer functions for any X-ray field region is proposed. The simulation procedures provide information of the changes of the focal spot sizes and, therefore, of the Point Spread Function (PSF) along the field. The evaluation yields the bi-dimensional optical Transfer Functions calculated from Fourier Transformation of the simulated PSFs. This method provides: the spatial frequency response for the entire radiation field of the radiological systems; comparisons of the image sharpness relative to equivalent field regions for different systems; and the study of a singular region in order to predict image distortions.
4

Avaliação ponto a ponto de sistemas de imagem radiológica utilizando funções de espalhamento de ponto simuladas. / Evaluating the focal sopt MTF in all radiological field location by computer simulation.

Paulo Mazzoncini de Azevedo Marques 23 September 1994 (has links)
Esta tese propõe um método de avaliação de sistemas de obtenção de imagem radiológica através das Funções de Transferência simuladas para qualquer região do campo de radiação. Esse processo de simulação reflete as mudanças sofridas pelo ponto focal e, portanto, pela Função de Espalhamento de Ponto (FEP) ao longo do campo. A avaliação utiliza informações obtidas de Funções de Transferência ótica bi-dimensionais calculadas através da aplicação de Transformadas de Fourier sobre as Funções de Espalhamento de Ponto simuladas. O método permite realizar um mapeamento da resposta em freqüências espaciais dos sistemas radio1ógicos para todo o campo de radiação, comparar a nitidez da imagem de sistemas distintos com relação a regiões equivalentes e estudar uma região especifica para prever as distorções que serão inseridas na imagem. / In this work a method of evaluation for the radiological imaging systems performance by simulated transfer functions for any X-ray field region is proposed. The simulation procedures provide information of the changes of the focal spot sizes and, therefore, of the Point Spread Function (PSF) along the field. The evaluation yields the bi-dimensional optical Transfer Functions calculated from Fourier Transformation of the simulated PSFs. This method provides: the spatial frequency response for the entire radiation field of the radiological systems; comparisons of the image sharpness relative to equivalent field regions for different systems; and the study of a singular region in order to predict image distortions.

Page generated in 0.1093 seconds