Spelling suggestions: "subject:"quality off tests"" "subject:"quality oof tests""
1 |
Quality of Test Design in Test Driven DevelopmentČaušević, Adnan January 2013 (has links)
One of the most emphasised software testing activities in an Agile environment is the usage of the Test Driven Development (TDD) approach. TDD is a development activity where test cases are created by developers before writing the code, and all for the purpose of guiding the actual development process. In other words, test cases created when following TDD could be considered as a by-product of software development. However, TDD is not fully adopted by the industry, as indicated by respondents from our industrial survey who pointed out that TDD is the most preferred but least practised activity. Our further research identified seven potentially limiting factors for industrial adoption of TDD, out of which one of the prominent factor was lack of developers’ testing skills. We subsequently defined and categorised appropriate quality attributes which describe the quality of test case design when following TDD. Through a number of empirical studies, we have clearly established the effect of “positive test bias”, where the participants focused mainly on the functionality while generating test cases. In other words, there existed less number of “negative test cases” exercising the system beyond the specified functionality, which is an important requirement for high reliability systems. On an average, in our studies, around 70% of test cases created by the participants were positive while only 30% were negative. However, when measuring defect detecting ability of those sets of test cases, an opposite ratio was observed. Defect detecting ability of negative test cases were above 70% while positive test cases contributed only by 30%. We propose a TDDHQ concept as an approach for achieving higher quality testing in TDD by using combinations of quality improvement aspects and test design techniques to facilitate consideration of unspecified requirements during the development to a higher extent and thus minimise the impact of potentially inherent positive test bias in TDD. This way developers do not necessarily focus only on verifying functionality, but they can as well increase security, robustness, performance and many other quality improvement aspects for the given software product. An additional empirical study, evaluating this method, showed a noticeable improvement in the quality of test cases created by developers utilising TDDHQ concept. Our research findings are expected to pave way for further enhancements to the way of performing TDD, eventually resulting in better adoption of it by the industry.
|
2 |
Využití testů s destruenty pro ekotoxikologické hodnocení kvality půd / Using tests with destruents for ecotoxicological evaluation of soil qualityRábová, Petra January 2020 (has links)
The aim of this diploma thesis was to determine the dehydrogenase activity of matrix samples that can enter the environment and the use of ecotoxicological tests to assess the quality of the affected soil. The effects of sludge, biochar samples, two landfill samples and a sediment sample were monitored. Ecotoxicology included tests on decomposers - tests of avoidance behavior (Eisenia fetida and Folsomia candida), acute, chronic and reproductive toxicity tests (Eisenia fetida) and Lactuca sativa root growth inhibition tests. The results indicate that dehydrogenase activity assays serve as a suitable complement to ecotoxicological tests. They provide valuable additional information on soil quality and sample effect after application to soil. The sediment sample had the least favorable effect on the activity of the enzyme and the vitality of the organisms, both in the determination of dehydrogenase activity and in ecotoxicological tests. Furthermore, it was found that biochar as a product of sewage sludge treatment is less toxic to organisms than the original sludge.
|
3 |
Aspectos da variabilidade experimental do ensaio de módulo de deformação do concreto. / Aspects of experimental variability of test method for static modulus of elasticity of concrete in compression.Montija, Fernando Celotto 03 August 2007 (has links)
Esta dissertação insere-se nas áreas de qualidade laboratorial e de ensaios de controle de concreto, especificamente quanto à propriedade módulo estático de deformação ou módulo de Young. A motivação do trabalho é a elevada variabilidade de resultados experimentais observada pelo meio técnico nacional em ensaios interlaboratoriais, cujos resultados indicam desvios-padrão totais da ordem de 3,5 GPa, valor significativo para o controle tecnológico de obras de construção civil. Os objetivos buscados foram a identificação das parcelas da variabilidade oriundas da produção e do ensaio, com especial atenção àquela originada na instrumentação para medida das deformações durante o ensaio, e a discussão da aplicabilidade do conceito semiprobabilístico normativo à propriedade módulo de deformação do concreto. Além disso, a própria discussão da aplicabilidade da sistemática de pesquisa e análise sobre este tipo de ensaio e de material constou como um objetivo do trabalho. Para tal, desenvolveu-se um programa experimental em duas etapas: a primeira foi destinada às avaliações de acurácia (precisão e exatidão) do método de ensaio. As avaliações se deram segundo roteiros da área metrológica para validação de métodos e sistemas de medida. De quatro instrumentações para medida das deformações testadas, uma se mostrou mais precisa (identificada como clip gages) e outra se mostrou a mais suscetível a erros sistemáticos e aleatórios entre as testadas (identificada como compressômetro com dois relógios comparadores). Recomendou-se a ampliação do programa experimental para o âmbito interlaboratorial, pois, a rigor, o método de ensaio vigente não poderia ser considerado validado em termos de acurácia baseando-se unicamente nos resultados deste programa experimental. Porém, concluiu-se pela possibilidade de aceitação prática do método independentemente da utilização de três de um total de quatro tipos de instrumentação para medida das deformações testados em ensaio, sem que houvesse prejuízo para a produção ou o controle tecnológico usual desta propriedade. Na segunda etapa, obteve-se um Diagrama de Dosagem e estudou-se um cenário de fornecimento de concreto sob critérios estatísticos diferentes de atendimento à especificação de módulo de deformação: utilização do valor característico e do valor médio, com diferença de 4 GPa entre eles. Estimou-se um aumento da ordem de 9% no deslocamento vertical de uma viga simples bi-apoiada quando executada com o concreto de menor módulo em relação à execução com o de maior módulo. Por sua vez, o concreto de maior módulo exigiria um aumento no consumo de cimento da ordem de até 200 kg/m3, se conservados todos os insumos materiais e os demais parâmetros tecnológicos contidos nos traços. Concluiu-se pela aplicabilidade do uso da sistemática empregada na avaliação da acurácia do método de ensaio e do uso do conceito semiprobabilístico para esta propriedade. / This work is developed into the areas of laboratorial quality and concrete control tests, specifically focusing on the static modulus of elasticity or Young´s modulus. The motivation of this work is the high variability of experimental results observed by national technicians in interlaboratorial tests. These results show total standard deviations of around 3.5 GPa, a significant value for the technological control for civil construction. The main objectives are the identification of the variability fragments derived from the production and test, specially the ones related to the instrumentation for measuring deformations during the test, and the discussion of the semi-probabilistic concept applicability on the concrete Young´s modulus control. Moreover, the discussion of the applicability of the procedure used in this work and its analysis are also objective pursued here. The experimental program was developed in two steps: the first step covered the accuracy assessments (precision and exactness) of test method. The assessments were carried out according to instructions from Metrology concepts for the validation of the methods and the measure systems. One out of four instrumentations for measuring the tested deformations proved to be more precise (identified as clip gages) and another one proved to be more susceptible to systematic and random errors (identified as a compressometer with two dial indicators). The extension of the experimental program to an interlaboratorial scope is recommended because the current test method could not be considered valid based only on the results of this experimental program. However, it was shown that the practical acceptance of the test method for three among the four kinds of instrumentations analyzed, without damaging the production or the usual technological control of this property, is possible. On the second step, a mix design diagram was obtained and a case of supply of concrete under different statistical criteria (fulfillment the modulus of elasticity specification): the use of the characteristic value and the average value, with difference of 4 GPa between them. An increase of 9% on the vertical transference of a simple dual supported beam was observed when using a lower modulus concrete, when compared to another one with a higher modulus. On the other hand, the modulus increase would require an increment in the cement consumption up to 200 kg per cubic meter, if all the material inputs and further technological parameters is maintained. The final conclusion was that the procedure used on the assessment of the test method accuracy and the semi-probabilistic concept on this material property is applicable.
|
4 |
Aspectos da variabilidade experimental do ensaio de módulo de deformação do concreto. / Aspects of experimental variability of test method for static modulus of elasticity of concrete in compression.Fernando Celotto Montija 03 August 2007 (has links)
Esta dissertação insere-se nas áreas de qualidade laboratorial e de ensaios de controle de concreto, especificamente quanto à propriedade módulo estático de deformação ou módulo de Young. A motivação do trabalho é a elevada variabilidade de resultados experimentais observada pelo meio técnico nacional em ensaios interlaboratoriais, cujos resultados indicam desvios-padrão totais da ordem de 3,5 GPa, valor significativo para o controle tecnológico de obras de construção civil. Os objetivos buscados foram a identificação das parcelas da variabilidade oriundas da produção e do ensaio, com especial atenção àquela originada na instrumentação para medida das deformações durante o ensaio, e a discussão da aplicabilidade do conceito semiprobabilístico normativo à propriedade módulo de deformação do concreto. Além disso, a própria discussão da aplicabilidade da sistemática de pesquisa e análise sobre este tipo de ensaio e de material constou como um objetivo do trabalho. Para tal, desenvolveu-se um programa experimental em duas etapas: a primeira foi destinada às avaliações de acurácia (precisão e exatidão) do método de ensaio. As avaliações se deram segundo roteiros da área metrológica para validação de métodos e sistemas de medida. De quatro instrumentações para medida das deformações testadas, uma se mostrou mais precisa (identificada como clip gages) e outra se mostrou a mais suscetível a erros sistemáticos e aleatórios entre as testadas (identificada como compressômetro com dois relógios comparadores). Recomendou-se a ampliação do programa experimental para o âmbito interlaboratorial, pois, a rigor, o método de ensaio vigente não poderia ser considerado validado em termos de acurácia baseando-se unicamente nos resultados deste programa experimental. Porém, concluiu-se pela possibilidade de aceitação prática do método independentemente da utilização de três de um total de quatro tipos de instrumentação para medida das deformações testados em ensaio, sem que houvesse prejuízo para a produção ou o controle tecnológico usual desta propriedade. Na segunda etapa, obteve-se um Diagrama de Dosagem e estudou-se um cenário de fornecimento de concreto sob critérios estatísticos diferentes de atendimento à especificação de módulo de deformação: utilização do valor característico e do valor médio, com diferença de 4 GPa entre eles. Estimou-se um aumento da ordem de 9% no deslocamento vertical de uma viga simples bi-apoiada quando executada com o concreto de menor módulo em relação à execução com o de maior módulo. Por sua vez, o concreto de maior módulo exigiria um aumento no consumo de cimento da ordem de até 200 kg/m3, se conservados todos os insumos materiais e os demais parâmetros tecnológicos contidos nos traços. Concluiu-se pela aplicabilidade do uso da sistemática empregada na avaliação da acurácia do método de ensaio e do uso do conceito semiprobabilístico para esta propriedade. / This work is developed into the areas of laboratorial quality and concrete control tests, specifically focusing on the static modulus of elasticity or Young´s modulus. The motivation of this work is the high variability of experimental results observed by national technicians in interlaboratorial tests. These results show total standard deviations of around 3.5 GPa, a significant value for the technological control for civil construction. The main objectives are the identification of the variability fragments derived from the production and test, specially the ones related to the instrumentation for measuring deformations during the test, and the discussion of the semi-probabilistic concept applicability on the concrete Young´s modulus control. Moreover, the discussion of the applicability of the procedure used in this work and its analysis are also objective pursued here. The experimental program was developed in two steps: the first step covered the accuracy assessments (precision and exactness) of test method. The assessments were carried out according to instructions from Metrology concepts for the validation of the methods and the measure systems. One out of four instrumentations for measuring the tested deformations proved to be more precise (identified as clip gages) and another one proved to be more susceptible to systematic and random errors (identified as a compressometer with two dial indicators). The extension of the experimental program to an interlaboratorial scope is recommended because the current test method could not be considered valid based only on the results of this experimental program. However, it was shown that the practical acceptance of the test method for three among the four kinds of instrumentations analyzed, without damaging the production or the usual technological control of this property, is possible. On the second step, a mix design diagram was obtained and a case of supply of concrete under different statistical criteria (fulfillment the modulus of elasticity specification): the use of the characteristic value and the average value, with difference of 4 GPa between them. An increase of 9% on the vertical transference of a simple dual supported beam was observed when using a lower modulus concrete, when compared to another one with a higher modulus. On the other hand, the modulus increase would require an increment in the cement consumption up to 200 kg per cubic meter, if all the material inputs and further technological parameters is maintained. The final conclusion was that the procedure used on the assessment of the test method accuracy and the semi-probabilistic concept on this material property is applicable.
|
Page generated in 0.0743 seconds