• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Nano systèmes électromécaniques résonants à haute fréquence (NEMS HF) : une rupture technologique pour l'imagerie infrarouge non refroidi / High frequency nano electro mechanical systems (NEMS HF) : a breakthrough in infrared imaging technology

Laurent, Ludovic 13 July 2017 (has links)
Les progrès de la microélectronique, axés en premier lieu sur l’amélioration des performances et la réduction des coûts des processeurs et des mémoires, ont aussi bénéficié depuis de nombreuses années aux capteurs, à l’éclairage, aux actionneurs et autres technologies dites More than Moore. La détection infrarouge à l’aide de détecteurs thermiques fait partie de ces bénéficiaires. Les détecteurs thermiques actuels utilisent principalement une fine couche résistive (typiquement du dioxyde de vanadium ou du silicium amorphe) déposée sur une membrane suspendue comme thermomètre : ce sont les microbolomètres. Cette technique a permis de produire des caméras thermiques dont le coût de fabrication a drastiquement chuté avec des performances qui se rapprochent des détecteurs photoniques onéreux, fonctionnant à des températures cryogéniques. Néanmoins, le coût de ces imageurs reste encore excessif pour des applications grand public (conduite nocturne, smartphones, domotique) tandis que les applications militaires (surveillance, lunettes portatives) demandent des performances accrues dans un budget maîtrisé. Un des objectifs des industriels du domaine est donc de réduire la surface des détecteurs, le pas pixel, afin d’augmenter le nombre de rétines fabriquées sur une plaque de silicium. Néanmoins, la réduction de cette surface diminue de facto le flux infrarouge incident sur le pixel, et donc le signal. Il faut donc améliorer la sensibilité des détecteurs à chaque nouveau pas pixel. La technologie résistive, largement employée par l’industrie jusqu’à maintenant, se prêtait volontiers à cet exercice jusqu’au pas de 17 µm, permettant de densifier d’un facteur 4 le nombre de détecteurs tous les 5 ans. L’auto-échauffement lié à la lecture résistive et le bruit en 1/f sont les principales causes du ralentissement observé dans cette réduction des échelles ces dernières années. Nos travaux se sont focalisés sur un nouveau principe de détection au pas de 12 µm, fonctionnant avec un auto-échauffement minime. Dans cette approche, une planche suspendue est mise en résonance mécanique autour de deux bras ancrés subissant une torsion. L’actionnement et la détection électrostatique du mouvement de la membrane sont réalisés avec deux électrodes situés 2 µm sous la planche. La modification du module d’Young avec la température et les contraintes thermiques vont modifier la fréquence de résonance. Les résonateurs mécaniques étant peu bruités, le suivi cette fréquence de résonance doit permettre de réaliser des détecteurs thermiques performants. Le travail de thèse a consisté à concevoir, fabriquer et caractériser de tels pixels et à comparer cette technique aux détecteurs résistifs. Différents modèles (linéaire et nonlinéaire) du mouvement de la structure sont présentés et comparés aux caractérisations expérimentales de résonateurs fabriqués en réseaux denses, selon différentes variantes. Nous avons mesuré le bruit fréquentiel de nos détecteurs puis leur sensibilité à un flux infrarouge. Les meilleurs dispositifs montrent une limite de sensibilité de 30 pW/√Hz. Une résolution sur la scène (NETD) de 2 K est obtenu pour un temps d’intégration adapté au temps image. Ces performances sont inégalées pour un résonateur non refroidi à ces dimensions. Nous montrons qu’un NETD de 20 mK est atteignable au pas de 12 µm (pour un temps de réponse de 10 ms) en se focalisant sur 3 axes de recherche : une cointégration des résonateurs avec leur électronique de lecture, une acquisition plus précise du signal par un temps d’intégration adapté au temps image et l’amélioration de la sensibilité thermique (TCF) du résonateur d’un facteur 10. Pour ce dernier point, nous présentons des méthodes afin d’améliorer le TCF. Finalement, nous étudions des architectures de pixels au pas de 5 µm présentant des performances théoriques proches de celles requises par l’imagerie infrarouge (NETD=70 mK et τth=8 ms). Des perspectives de transductions tout optiques sont finalement évoquées. / Progress in microelectronics has been mainly driven by informatics needs for addressing both increased performances and lower costs for processors and memories, according to the well-known Moore’s Law. For many years, these tremendous progresses in silicon fabrication and integration have also contributed to the emergence of new type of devices, such as sensors, actuators, filters, clocks or imagers, forming a new class of devices called More than Moore. Uncooled infrared imaging, which uses thermal sensors belongs to this new class of devices. Today thermal sensors principally use a thin resistive layer (mainly vanadium dioxide or amorphous silicon) on a suspended membrane as a thermometer and are called microbolometers. The fabrication cost of thermal cameras has dramatically dropped over the last 20 years, while attaining performances close to the expensive cooled cameras. Nevertheless, the cost of these imagers still remains too high for consumer market (night driving, smartphones, home automation) whereas military applications (surveillance, personal googles) need improved resolutions – in an affordable camera. Therefore, one objective of the microbolometers industry roadmap is to scale down the sensor surface – the pixel pitch – in order to increase the number of imagers fabricated on a silicon wafer. Yet, the pixel pitch reduction goes necessarily with a reduction of the captured infrared power leading to a reduction of the sensor signal. As a consequence, the sensor sensitivity needs to be improved as the pixel pitch scales down. The resistive technology has managed this scaling so far, down to 17µm pixel pitch, allowing a densification of the sensors by a factor 4 every 5 years. Despite this success, the scaling has been recently slowed down, mostly because of microbolometers self-heating issue and 1/f noise which are inherent to the resistive transduction. Our work has focused on a new type of sensor at 12µm pixel pitch, which theoretically gets rid of self-heating and 1/f noise. In our approach, an absorbing plate is excited at its mechanical resonance through two tiny torsion arms using an actuation electrode placed 2µm underneath. Pixel motion is also transduced electrostatically. Since micromechanical resonators feature very low frequency noise, we believe that an uncooled infrared sensor based on the monitoring of its resonance frequency (which changes with temperature through the TCF) should be extremely sensitive. In our work, we present different models (linear and nonlinear) for the pixel mechanical behavior and compare them to experimental characterization of resonators which were fabricated in dense arrays, according to several designs. We measure the frequency stability of our sensors along with their sensitivity to infrared flux. The best devices show a resolution of 30pW/sqrt(Hz), with a response time lower than one millisecond. The scene resolution (NETD) is 2K for an integration time compatible with imaging frame rate. These performances overtake results previously published on this topic with such reduced pixel pitch. We show that a NETD of 20mK (with a response time of 10ms) is reachable at 12µm pixel pitch if we can address the following 3 challenges: a cointegration of the resonators with their electronics, a shared readout of several pixels in the imaging frame rate and an improved TCF by a factor 10. Therefore, we provide different methods in order to improve the TCF. Finally, we present different pixel designs at 5µm pixel pitch which show theoretical performances close to uncooled infrared imaging requirements (NETD=70mK and tau_th=8ms). An optical transduction may also be a new route toward even better signal to noise ratio at low pitch.
2

Désorption forcée de tensioactifs à l'interface polymère-eau

Clauzel, Maryline 14 November 2006 (has links) (PDF)
Les recherches présentées dans ce mémoire s'intéressent à la désorption du tensioactif dans les films de latex en cours de séchage. Les travaux concernent d'une part l'élaboration d'un système expérimental modélisant le rapprochement de deux particules de latex recouvertes de tensioactif pour accéder aux paramètres influençant la désorption, et d'autre part l'étude de ce phénomène directement sur un latex. Un protocole pertinent de fabrication d'un film polymère mince déposé sur du mica, de faible rugosité, et résistant à une immersion prolongée dans un milieu aqueux a été obtenu. L'adsorption d'un tensioactif anionique, le dodécyl sulfate de sodium (SDS) sur un film polymère de poly (méthacrylate d'éthyle) (PEMA) est investiguée par microscopie à force atomique et indique la présence d'agrégats de surface dont la densité croit lorsque la concentration en tensioactif dans la solution dépasse la concentration micellaire critique (CMC). Le profil des interactions s'exerçant entre deux surfaces de polymère immergées en solutions aqueuses de tensioactif en fonction de la séparation entre les interfaces est obtenu par la technique de mesure des forces de surface (surface force apparatus, SFA), et permet de répondre à la question de l'occurrence ou non de la désorption du tensioactif (SDS) lorsque le milieu aqueux intermédiaire séparant les interfaces de PEMA est réduit jusqu'au contact physique, comme dans le mécanisme de séchage lorsque les colloïdes de latex se rapprochent au fur et à mesure que l'eau disparaît. L'étude de la désorption du tensioactif dans un système réel, à savoir lors du séchage d'un film de latex, est menée par mesures d'anisotropie de fluorescence et mesures par résonateur de torsion et montre la simultanéité entre la perte de mobilité de la sonde fluorescente hydrophile et l'évaporation de l'eau, augurant d'un comportement analogue pour le tensioactif.

Page generated in 0.1298 seconds