• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação da concentração de 222Rn e filhos em ambientes fechados com detectores plásticos / Determination of the concentration of 222 Rn and children indoors with plastic detectors.

Silva, Almy Anacleto Rodrigues da 25 April 2000 (has links)
A presença de altas concentrações de 222Rn e filhos em ambientes fechados tem sido objeto de várias pesquisas e de muitas discussões sobre o real problema que tais concentrações poder trazer à saúde. Essa discussão será mais objetiva e quantitativa se foram conhecidas as doses e se estudos epidemiológicos forem direcionados para o conhecimento dos efeitos da radiação no corpo humano. Este trabalho também foram considerados os efeitos do plate-out, uma característica dos filhos do radônio de se depositarem nas paredes, solo, teto, móveis e meios materiais em geral, ocasionando uma redução na atividade dos filhos do radônio presentes no ar ao redor dessas superfícies, mostrou-se como a melhor forma, de baixo custo e de fácil uso, para a detecção. Sua calibração foi efetuada a partir de medidas com CR39, cujo método também leva em consideração os efeitos do plate-out. Foi feito um estudo das características do LR115 e das condições de ataque químico que maximizam sua resposta; também foram desenvolvidos critérios de leitura, a fim de se escolher o que permite melhor identificação dos traços, com boa eficiência e menor subjetividade. Os resultados obtidos para tais características mostraram consistência com outros resultados encontrados na literatura. A calibração relativa entre os detectores foi feita a partir de exposições simultâneas em ambientes controlados e também em diferentes ambientes fechados e de convívio humano, onde os fatores ambientais são mais importantes. Comparando os resultados nessas duas situações verifica-se uma diferença significativa no fator de calibração (razão entre a densidade de traços e a concentração de emissões alfa) obtido em cada uma (0.60 ± 0,04) cm e (0,43 ± 0,03) cm respectivamente. Foi verificado também um aumento da resposta com a elevação da densidade de traços para exposições com 241Am. Tais resultados apontam para uma supralinearidade da resposta do detector em situações de alta densidade de traços ou para a existência de algum fator intrínseco ao sistema de detecção e calibração como um todo. O fator de calibração obtido em exposições em ambientes de convívio humano é mais apropriado para o uso na monitoração de radônio e filhos, quando se pretende considerar os efeitos do plate-out. Uma aplicação em algumas residências (casas e apartamentos) foi efetuada e as concentrações de emissões alfa variam de (21 ± 7) a (228 ± 21) Bq/m3. / The presence of high indoor concentration of 222Rn and daughters has been object of various studies and discussion about the actual health problem that these radioelements may cause. The aim of this work is to collaborate with the dosimetry of 222Rn and daughters, developing a low cost and easy to use methodology to determine the indoor alpha emission concentration. This methodology is based on passive detection with CR39 and LR115 solid state nuclear track detectors (SSNTD). This work considered the plate-out effect, a characteristic of radon daughters that renders their deposition on walls, soil, ceiling, furniture and materials in general, causing a reduction in activity of radon daughters in the air surrounding these surfaces. LR115 plastics, whose response to self plate-out effects is negligible, proved to be the best form to carry out this detection, when low cost and easyness of use are considered. Its calibration was done in ambients where CR39 measurements of concentration were available, with a method that also considers the plate-out effect. A study of the characteristics of LR115 detector was performed and the etching conditions that turn maximum its response were found. Various criteria for counting the tracks were tested, to choose the one that allows the easiest track identification and a good efficiency, with less subjectivity. The results showed consistency with others found in literature. A relative calibration between the two detectors was done by simultaneous indoor exposures in controlled environments and in dwellings, where the environmental factors are more important. The results obtained in these two conditions showed a significant difference between the calibration factors (ratio between the track density and the alpha emission concentration) obtained: (0,69 ± 0,04) cm and (0,43 ± 0,03) cm respectively. It was also noticed an increase of LR115 response with the track density for 241Am exposures. These outcomes point out to a supralinear behavior of the detector response in high track density situations or to other factors inherent to all detection and calibration system. The calibration factor obtained for dwelling exposure is more appropriated to use in monitoring of222Rn and daughters when the plate-out effects are considered. An application in some residences was made and the alpha emission concentration varied between (21 ± 7) and (228 ± 21) Bq/m3.
2

Determinação da concentração de 222Rn e filhos em ambientes fechados com detectores plásticos / Determination of the concentration of 222 Rn and children indoors with plastic detectors.

Almy Anacleto Rodrigues da Silva 25 April 2000 (has links)
A presença de altas concentrações de 222Rn e filhos em ambientes fechados tem sido objeto de várias pesquisas e de muitas discussões sobre o real problema que tais concentrações poder trazer à saúde. Essa discussão será mais objetiva e quantitativa se foram conhecidas as doses e se estudos epidemiológicos forem direcionados para o conhecimento dos efeitos da radiação no corpo humano. Este trabalho também foram considerados os efeitos do plate-out, uma característica dos filhos do radônio de se depositarem nas paredes, solo, teto, móveis e meios materiais em geral, ocasionando uma redução na atividade dos filhos do radônio presentes no ar ao redor dessas superfícies, mostrou-se como a melhor forma, de baixo custo e de fácil uso, para a detecção. Sua calibração foi efetuada a partir de medidas com CR39, cujo método também leva em consideração os efeitos do plate-out. Foi feito um estudo das características do LR115 e das condições de ataque químico que maximizam sua resposta; também foram desenvolvidos critérios de leitura, a fim de se escolher o que permite melhor identificação dos traços, com boa eficiência e menor subjetividade. Os resultados obtidos para tais características mostraram consistência com outros resultados encontrados na literatura. A calibração relativa entre os detectores foi feita a partir de exposições simultâneas em ambientes controlados e também em diferentes ambientes fechados e de convívio humano, onde os fatores ambientais são mais importantes. Comparando os resultados nessas duas situações verifica-se uma diferença significativa no fator de calibração (razão entre a densidade de traços e a concentração de emissões alfa) obtido em cada uma (0.60 ± 0,04) cm e (0,43 ± 0,03) cm respectivamente. Foi verificado também um aumento da resposta com a elevação da densidade de traços para exposições com 241Am. Tais resultados apontam para uma supralinearidade da resposta do detector em situações de alta densidade de traços ou para a existência de algum fator intrínseco ao sistema de detecção e calibração como um todo. O fator de calibração obtido em exposições em ambientes de convívio humano é mais apropriado para o uso na monitoração de radônio e filhos, quando se pretende considerar os efeitos do plate-out. Uma aplicação em algumas residências (casas e apartamentos) foi efetuada e as concentrações de emissões alfa variam de (21 ± 7) a (228 ± 21) Bq/m3. / The presence of high indoor concentration of 222Rn and daughters has been object of various studies and discussion about the actual health problem that these radioelements may cause. The aim of this work is to collaborate with the dosimetry of 222Rn and daughters, developing a low cost and easy to use methodology to determine the indoor alpha emission concentration. This methodology is based on passive detection with CR39 and LR115 solid state nuclear track detectors (SSNTD). This work considered the plate-out effect, a characteristic of radon daughters that renders their deposition on walls, soil, ceiling, furniture and materials in general, causing a reduction in activity of radon daughters in the air surrounding these surfaces. LR115 plastics, whose response to self plate-out effects is negligible, proved to be the best form to carry out this detection, when low cost and easyness of use are considered. Its calibration was done in ambients where CR39 measurements of concentration were available, with a method that also considers the plate-out effect. A study of the characteristics of LR115 detector was performed and the etching conditions that turn maximum its response were found. Various criteria for counting the tracks were tested, to choose the one that allows the easiest track identification and a good efficiency, with less subjectivity. The results showed consistency with others found in literature. A relative calibration between the two detectors was done by simultaneous indoor exposures in controlled environments and in dwellings, where the environmental factors are more important. The results obtained in these two conditions showed a significant difference between the calibration factors (ratio between the track density and the alpha emission concentration) obtained: (0,69 ± 0,04) cm and (0,43 ± 0,03) cm respectively. It was also noticed an increase of LR115 response with the track density for 241Am exposures. These outcomes point out to a supralinear behavior of the detector response in high track density situations or to other factors inherent to all detection and calibration system. The calibration factor obtained for dwelling exposure is more appropriated to use in monitoring of222Rn and daughters when the plate-out effects are considered. An application in some residences was made and the alpha emission concentration varied between (21 ± 7) and (228 ± 21) Bq/m3.
3

Doses populacionais de radiação ionizante na cidade de São Paulo: medidas de dose gama a céu aberto.

Oliveira, Raimundo Enoch Rodrigues 16 March 2001 (has links)
Os efeitos da radiação ionizante aos seres humanos são sobejamente conhecidos para doses altas e intermediárias, ao passo que há muitas controvérsias sobre os efeitos de irradiações com baixa intensidade. Para que se possa entender melhor tais efeitos é necessário que se conheçam bem essas doses. No presente estudo, fez-se um levantamento da média anual da taxa de equivalente de dose ambiente H*(10) à qual as pessoas estão expostas na cidade de São Paulo, uma vez que inexistem dados a esse respeito na literatura. Para tal, traçou-se rotas de maneira a se cobrir a maior e mais representativa área da cidade e, na escolha dos pontos de coleta de dados, levou-se em consideração principalmente o fator ocupação. Utilizou-se um sistema de espectrometria gama, portátil, que fornece automaticamente, a taxa de H*(10) e o espectro gama medido (no intervalo de 50 a 1670 keV) no local de interesse, dentro de um intervalo de tempo curto por se detectar contribuições de uma fonte muito extensa. As medidas foram realizadas a 1 m do solo e adotou-se 300 s como tempo de medida. Os valores medidos variaram de 33,1 a 152,3 nSv.h-1, descontada a contribuição dos raios cósmicos, o desvio padrão da amostra foi de 22 nSv.h-1 e a média obtida para a cidade de São Paulo foi de 96,1(24) nSv.h-1. Além disto, calcularam-se as médias da taxa de equivalente de dose ambiente para os cinco Núcleos de Saúde nos quais a Secretaria de Saúde do Estado de São Paulo dividiu a cidade. O teste estatístico t de Student indicou uma não homogeneidade do conjunto de dados, com o que se vê necessária a realização de um levantamento mais detalhado a fim de se verificar a natureza de tal diferença. A fim de se comparar o valor médio obtido para a cidade de São Paulo com os valores encontrados na literatura para outras regiões do mundo, converteu-se o valor obtido de equivalente de dose ambiente para dose efetiva. Com isto, pode-se notar que a média anual de dose efetiva para a cidade de São Paulo, de 0,522(13) mSv é superior à estimativa média para o mundo fornecida pelo UNSCEAR – United Nations Scientific Commitee on the Effects of Atomic Radiation, de 0,40 mSv, valor esse que também só leva em conta a contribuição de radiação gama a céu aberto. / The effects of ionizing radiation to the human beings are well known for high and intermediate doses. As far as low level radiation doses are concerned, there is no consensus. In order to get a better understanding of such effects it is necessary to assess the low doses with better accuracy. In this work, it was made an estimate of the annual ambient dose equivalent (H*(10)) to which the people are exposed in the city of São Paulo. Until now there are no data about it available in the literature. For the purpose of this evaluation, a map with various routes covering the largest and more representative area of the city was designed. The choice of points for data collection was made taking into account mainly the occupancy of the region. A portable gamma spectrometry system was used. It furnishes the rate of H*(10) and the measured gamma spectrum (in the range from 50 to 1670 keV) in the place of interest. The measurements were performed in a short time interval, since the gamma radiation arrives from a great extent of soil. Each measurement was done 1 m above the soil during 300 s. The rates of H*(10) varied from 33.1 to 152.3 nSv.h-1, net values, obtained after subtraction of the cosmic rays contribution. The standard deviation was 22 nSv.h-1 for an average for the city of São Paulo of 96.1(24) nSv.h-1. In addition, average values of H*(10) rates for the city Health Divisions were calculated. Those values are not statistically equivalent and the whole set of data could not be treated as one, as the statistical Student test indicated a non homogeneity of the group of data. Hence it is necessary the accomplishment of a more detailed survey in order verify the origin of the discrepancy. The mean value of H*(10) rate obtained for the city of São Paulo was converted to effective dose, in order to be compared with other places’ results. It could be noticed that the annual average of effective dose for the city of São Paulo, 0.522(13) mSv, is superior to the world average estimate of 0.40 mSv, supplied by UNSCEAR – United Nations Scientific Commitee on the Effects of Atomic Radiation, value that also takes into account only the outdoor gamma contribution.
4

Doses populacionais de radiação ionizante na cidade de São Paulo: medidas de dose gama a céu aberto.

Raimundo Enoch Rodrigues Oliveira 16 March 2001 (has links)
Os efeitos da radiação ionizante aos seres humanos são sobejamente conhecidos para doses altas e intermediárias, ao passo que há muitas controvérsias sobre os efeitos de irradiações com baixa intensidade. Para que se possa entender melhor tais efeitos é necessário que se conheçam bem essas doses. No presente estudo, fez-se um levantamento da média anual da taxa de equivalente de dose ambiente H*(10) à qual as pessoas estão expostas na cidade de São Paulo, uma vez que inexistem dados a esse respeito na literatura. Para tal, traçou-se rotas de maneira a se cobrir a maior e mais representativa área da cidade e, na escolha dos pontos de coleta de dados, levou-se em consideração principalmente o fator ocupação. Utilizou-se um sistema de espectrometria gama, portátil, que fornece automaticamente, a taxa de H*(10) e o espectro gama medido (no intervalo de 50 a 1670 keV) no local de interesse, dentro de um intervalo de tempo curto por se detectar contribuições de uma fonte muito extensa. As medidas foram realizadas a 1 m do solo e adotou-se 300 s como tempo de medida. Os valores medidos variaram de 33,1 a 152,3 nSv.h-1, descontada a contribuição dos raios cósmicos, o desvio padrão da amostra foi de 22 nSv.h-1 e a média obtida para a cidade de São Paulo foi de 96,1(24) nSv.h-1. Além disto, calcularam-se as médias da taxa de equivalente de dose ambiente para os cinco Núcleos de Saúde nos quais a Secretaria de Saúde do Estado de São Paulo dividiu a cidade. O teste estatístico t de Student indicou uma não homogeneidade do conjunto de dados, com o que se vê necessária a realização de um levantamento mais detalhado a fim de se verificar a natureza de tal diferença. A fim de se comparar o valor médio obtido para a cidade de São Paulo com os valores encontrados na literatura para outras regiões do mundo, converteu-se o valor obtido de equivalente de dose ambiente para dose efetiva. Com isto, pode-se notar que a média anual de dose efetiva para a cidade de São Paulo, de 0,522(13) mSv é superior à estimativa média para o mundo fornecida pelo UNSCEAR – United Nations Scientific Commitee on the Effects of Atomic Radiation, de 0,40 mSv, valor esse que também só leva em conta a contribuição de radiação gama a céu aberto. / The effects of ionizing radiation to the human beings are well known for high and intermediate doses. As far as low level radiation doses are concerned, there is no consensus. In order to get a better understanding of such effects it is necessary to assess the low doses with better accuracy. In this work, it was made an estimate of the annual ambient dose equivalent (H*(10)) to which the people are exposed in the city of São Paulo. Until now there are no data about it available in the literature. For the purpose of this evaluation, a map with various routes covering the largest and more representative area of the city was designed. The choice of points for data collection was made taking into account mainly the occupancy of the region. A portable gamma spectrometry system was used. It furnishes the rate of H*(10) and the measured gamma spectrum (in the range from 50 to 1670 keV) in the place of interest. The measurements were performed in a short time interval, since the gamma radiation arrives from a great extent of soil. Each measurement was done 1 m above the soil during 300 s. The rates of H*(10) varied from 33.1 to 152.3 nSv.h-1, net values, obtained after subtraction of the cosmic rays contribution. The standard deviation was 22 nSv.h-1 for an average for the city of São Paulo of 96.1(24) nSv.h-1. In addition, average values of H*(10) rates for the city Health Divisions were calculated. Those values are not statistically equivalent and the whole set of data could not be treated as one, as the statistical Student test indicated a non homogeneity of the group of data. Hence it is necessary the accomplishment of a more detailed survey in order verify the origin of the discrepancy. The mean value of H*(10) rate obtained for the city of São Paulo was converted to effective dose, in order to be compared with other places’ results. It could be noticed that the annual average of effective dose for the city of São Paulo, 0.522(13) mSv, is superior to the world average estimate of 0.40 mSv, supplied by UNSCEAR – United Nations Scientific Commitee on the Effects of Atomic Radiation, value that also takes into account only the outdoor gamma contribution.

Page generated in 0.0563 seconds