• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design and Testing of a High Gradient Radio Frequency Cavity for the Muon Collider

Wu, Vincent 21 June 2002 (has links)
No description available.
2

Calibration Model for Detection of Potential Demodulating Behaviour in Biological Media Exposed to RF Energy

Abd-Alhameed, Raed, See, Chan H., Excell, Peter S., McEwan, Neil J., Ali, N.T. 11 May 2017 (has links)
Yes / Potential demodulating ability in biological tissue exposed to Radio Frequency (RF) signals intrinsically requires an unsymmetrical diode-like nonlinear response in tissue samples. This may be investigated by observing possible generation of the second harmonic in a cavity resonator designed to have fundamental and second harmonic resonant frequencies with collocated antinodes. Such a response would be of interest as being a mechanism that could enable demodulation of information-carrying waveforms having modulating frequencies in ranges that could interfere with cellular processes. Previous work has developed an experimental system to test for such responses: the present work reports an electric circuit model devised to facilitate calibration of any putative nonlinear RF energy conversion occurring within a nonlinear test-piece inside the cavity. The method is validated computationally and experimentally using a well-characterised nonlinear device. The variations of the reflection coefficients of the fundamental and second harmonic responses of the cavity due to adding nonlinear and lossy material are also discussed. The proposed model demonstrates that the sensitivity of the measurement equipment plays a vital role in deciding the required input power to detect any second harmonic signal, which is expected to be very weak. The model developed here enables the establishment of a lookup table giving the level of the second harmonic signal in the detector as a function of the specific input power applied in a measurement. Experimental results are in good agreement with the simulated results. / Engineering and Physical Science Research Council through Grant EP/E022936A

Page generated in 0.0515 seconds