• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 63
  • Tagged with
  • 63
  • 63
  • 21
  • 18
  • 15
  • 15
  • 15
  • 12
  • 12
  • 9
  • 9
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo comparativo da Panorametria de Puricelli na radiografia panorâmica e reconstrução panorâmica de tomografia computadorizada de feixe cônico

Martins, Gustavo Lisboa January 2010 (has links)
A radiografia panorâmica, tecnicamente resultante da projeção de um sistema rotacional, permite uma visão ampla do complexo bucomaxilofacial. Além das arcadas dentárias, estruturas ósseas fixas e articuladas, oferece ainda imagens anatômicas das cavidades orbitárias, fossas nasais, seios maxilares e espaços aéreos. Entretanto, este meio auxiliar de diagnóstico apresenta limitações, principalmente no que diz respeito a distorções e magnificações. A aquisição de imagem da tomografia computadorizada de feixe cônico (TCFC) surge como uma ferramenta de custo acessível, baixa exposição à radiação X e fidelidade de imagem, sem distorções e em tamanho real. Buscamos estabelecer a reprodução dos estudos graficométricos da Panorametria, proposta por Puricelli (2004), sobre imagens panorâmicas multiplanares adquiridas no modo MIP (Projeção de Intensidade Máxima), com o objetivo de comparar as diferenças entre as medidas lineares e angulares advindas da radiografia panorâmica convencional. Cinqüenta e quatro conjuntos de imagens panorâmicas convencionais e panorâmicas de TCFC, do mesmo paciente, foram avaliados. A Panorametria foi realizada através de traçados manuais, em ambos os filmes, por três examinadores. A reproductibilidade dos examinadores foi de ótima a excelente nas radiografias panorâmicas e de panorâmicas de TCFC (0,86±0,07 e 0,88±0,07, respectivamente). A magnificação total da radiografia panorâmica, para as medidas estudadas, foi de 4,3%, sendo maior no sentido vertical (12%) e horizontal inferior (11,5%) em comparação às medidas angulares das retas (6,7%) e horizontal superior (1,9%). Houve minimização angular em ambos os lados da radiografia panorâmica, em comparação a panorâmica de TCFC. Mais estudos são necessários para avaliar a panorâmica de TCFC adquirida no modo MIP, a fim de se conhecer mais sobre as suas características de reconstrução e distorção. / The panoramic radiograph, technical resultant of the projection of a rotational system, allows a wide view of the maxillofacial complex. Beyond the dental arches, fixed and articulated osseous structures, still offers anatomical images of orbital sockets, nasal fosses, maxillary sinus and airspaces. However, this auxiliary diagnosis mean presents limitations, mainly by means of distortions and magnifications. The Cone Beam Computed Tomography (CBCT) appears as a tool of accessible costs, low exposition to radiation X and image allegiance, without distortions and in real size. Aiming to establish a the reproduction of graphic and metrical studies of Panorametry, proposed by Puricelli (2004), on the multiplanar panoramic images acquired by MIP (Maximum Intensity Projection) mode, with the objective of comparing the differences between the linear and angular measurements from the conventional panoramic radiography. Fifty-four sets of conventional panoramic radiographs and CBCT panoramic MIP reconstructions, from the same patient, had been evaluated. The Panorametry was done by manually tracings, in both films, by three examiners. The correlation of the examiners was excellent in the panoramic radiographs and the CBCT panoramic MIP reconstructions (0,86±0,07 and 0,88±0,07, respectively). The total magnification of panoramic radiograph, for the studied measurements, was of 4,3%, being higher in the vertical direction (12%) and the horizontal inferior line (11,5%) in comparison to the angular measurements of the straight lines (6,7%) and the horizontal superior lines (1,9%). There was angular minimization in both sides of the panoramic radiograph, in comparison to the CBCT. More studies are necessary to evaluate CBCT panoramic MIP reconstructions, in order to know more about its characteristics of reconstruction and distortion.
2

Avaliação radiográfica da projeção das espinhas mentais em relação ao forame lingual

Baldissera, Elaine de Fátima Zanchin January 2001 (has links)
Resumo não disponível.
3

Pós-processamento de imagens digitalizadas na odontometria de primeiros pré-molares superiores

Santos, Antônio Furlan dos January 2001 (has links)
A partir de uma amostra de 30 radiografias mesiorradiais prémolares superiores, contendo um instrumento endodôntico em cada um de seus condutos, obtidas com a finalidade de odontometria, foi avaliado se a manipulação digital pela aplicação de filtros grráficos de inversão, pseudocolorização e relevo, favorece ou não a localização do ápice radiográfico.As imagens convencionais foram digitalizadas através de scanner em 300 dpi e 256 tons de cinca, tamanho original e ajuste automático de brilho e contraste, reproduzidas três vezes e submetidas aos filtros gráficos. Uma seqüência aleatória de todas as imagens foi apresentada em monitor, em condições padronizadas de visualização, a um observador habituado à utilização de imagens digitais que, através de régua eletrônica da barra de ferramentas do programa PhotoshopR, efetuou a medida da distância entre a borda superior da imagem e o limite apical para ambas as raízes, três vezes em oportunidades distintas. As quatro imagens de cada dente foram montadas em apresentação do programa PowerPointR e exibidas, com os mesmos critérios de padronização, para três observadores especialistas em endodontia, os quais qualitativamente em qual delas o limite apical de cada raiz era melhor visualizado. Através dos resultados do teste não-paramétrico de Friedman verificou-se que os valores médios para as imagens manipuladas não diferem significativamente daqueles obtidos sobre a imagem (p=0,001), onde se observa o maior coeficiente de variação. A imagem e sua versão em negativo foram classificadas como as melhores de forma mais consistente. A modalidade pseudocores e relevo receberam os piores escores, porém não de modo consistente.
4

Avaliação da reprodutibilidade na interpretação de imagens por ressonância magnética nuclear da articulação temporomandibular

Butzke, Karine Wagner January 2007 (has links)
Resumo não disponível.
5

Estudo comparativo da Panorametria de Puricelli na radiografia panorâmica e reconstrução panorâmica de tomografia computadorizada de feixe cônico

Martins, Gustavo Lisboa January 2010 (has links)
A radiografia panorâmica, tecnicamente resultante da projeção de um sistema rotacional, permite uma visão ampla do complexo bucomaxilofacial. Além das arcadas dentárias, estruturas ósseas fixas e articuladas, oferece ainda imagens anatômicas das cavidades orbitárias, fossas nasais, seios maxilares e espaços aéreos. Entretanto, este meio auxiliar de diagnóstico apresenta limitações, principalmente no que diz respeito a distorções e magnificações. A aquisição de imagem da tomografia computadorizada de feixe cônico (TCFC) surge como uma ferramenta de custo acessível, baixa exposição à radiação X e fidelidade de imagem, sem distorções e em tamanho real. Buscamos estabelecer a reprodução dos estudos graficométricos da Panorametria, proposta por Puricelli (2004), sobre imagens panorâmicas multiplanares adquiridas no modo MIP (Projeção de Intensidade Máxima), com o objetivo de comparar as diferenças entre as medidas lineares e angulares advindas da radiografia panorâmica convencional. Cinqüenta e quatro conjuntos de imagens panorâmicas convencionais e panorâmicas de TCFC, do mesmo paciente, foram avaliados. A Panorametria foi realizada através de traçados manuais, em ambos os filmes, por três examinadores. A reproductibilidade dos examinadores foi de ótima a excelente nas radiografias panorâmicas e de panorâmicas de TCFC (0,86±0,07 e 0,88±0,07, respectivamente). A magnificação total da radiografia panorâmica, para as medidas estudadas, foi de 4,3%, sendo maior no sentido vertical (12%) e horizontal inferior (11,5%) em comparação às medidas angulares das retas (6,7%) e horizontal superior (1,9%). Houve minimização angular em ambos os lados da radiografia panorâmica, em comparação a panorâmica de TCFC. Mais estudos são necessários para avaliar a panorâmica de TCFC adquirida no modo MIP, a fim de se conhecer mais sobre as suas características de reconstrução e distorção. / The panoramic radiograph, technical resultant of the projection of a rotational system, allows a wide view of the maxillofacial complex. Beyond the dental arches, fixed and articulated osseous structures, still offers anatomical images of orbital sockets, nasal fosses, maxillary sinus and airspaces. However, this auxiliary diagnosis mean presents limitations, mainly by means of distortions and magnifications. The Cone Beam Computed Tomography (CBCT) appears as a tool of accessible costs, low exposition to radiation X and image allegiance, without distortions and in real size. Aiming to establish a the reproduction of graphic and metrical studies of Panorametry, proposed by Puricelli (2004), on the multiplanar panoramic images acquired by MIP (Maximum Intensity Projection) mode, with the objective of comparing the differences between the linear and angular measurements from the conventional panoramic radiography. Fifty-four sets of conventional panoramic radiographs and CBCT panoramic MIP reconstructions, from the same patient, had been evaluated. The Panorametry was done by manually tracings, in both films, by three examiners. The correlation of the examiners was excellent in the panoramic radiographs and the CBCT panoramic MIP reconstructions (0,86±0,07 and 0,88±0,07, respectively). The total magnification of panoramic radiograph, for the studied measurements, was of 4,3%, being higher in the vertical direction (12%) and the horizontal inferior line (11,5%) in comparison to the angular measurements of the straight lines (6,7%) and the horizontal superior lines (1,9%). There was angular minimization in both sides of the panoramic radiograph, in comparison to the CBCT. More studies are necessary to evaluate CBCT panoramic MIP reconstructions, in order to know more about its characteristics of reconstruction and distortion.
6

Avaliação radiográfica da projeção das espinhas mentais em relação ao forame lingual

Baldissera, Elaine de Fátima Zanchin January 2001 (has links)
Resumo não disponível.
7

Pós-processamento de imagens digitalizadas na odontometria de primeiros pré-molares superiores

Santos, Antônio Furlan dos January 2001 (has links)
A partir de uma amostra de 30 radiografias mesiorradiais prémolares superiores, contendo um instrumento endodôntico em cada um de seus condutos, obtidas com a finalidade de odontometria, foi avaliado se a manipulação digital pela aplicação de filtros grráficos de inversão, pseudocolorização e relevo, favorece ou não a localização do ápice radiográfico.As imagens convencionais foram digitalizadas através de scanner em 300 dpi e 256 tons de cinca, tamanho original e ajuste automático de brilho e contraste, reproduzidas três vezes e submetidas aos filtros gráficos. Uma seqüência aleatória de todas as imagens foi apresentada em monitor, em condições padronizadas de visualização, a um observador habituado à utilização de imagens digitais que, através de régua eletrônica da barra de ferramentas do programa PhotoshopR, efetuou a medida da distância entre a borda superior da imagem e o limite apical para ambas as raízes, três vezes em oportunidades distintas. As quatro imagens de cada dente foram montadas em apresentação do programa PowerPointR e exibidas, com os mesmos critérios de padronização, para três observadores especialistas em endodontia, os quais qualitativamente em qual delas o limite apical de cada raiz era melhor visualizado. Através dos resultados do teste não-paramétrico de Friedman verificou-se que os valores médios para as imagens manipuladas não diferem significativamente daqueles obtidos sobre a imagem (p=0,001), onde se observa o maior coeficiente de variação. A imagem e sua versão em negativo foram classificadas como as melhores de forma mais consistente. A modalidade pseudocores e relevo receberam os piores escores, porém não de modo consistente.
8

Avaliação da reprodutibilidade na interpretação de imagens por ressonância magnética nuclear da articulação temporomandibular

Butzke, Karine Wagner January 2007 (has links)
Resumo não disponível.
9

Estudo comparativo da Panorametria de Puricelli na radiografia panorâmica e reconstrução panorâmica de tomografia computadorizada de feixe cônico

Martins, Gustavo Lisboa January 2010 (has links)
A radiografia panorâmica, tecnicamente resultante da projeção de um sistema rotacional, permite uma visão ampla do complexo bucomaxilofacial. Além das arcadas dentárias, estruturas ósseas fixas e articuladas, oferece ainda imagens anatômicas das cavidades orbitárias, fossas nasais, seios maxilares e espaços aéreos. Entretanto, este meio auxiliar de diagnóstico apresenta limitações, principalmente no que diz respeito a distorções e magnificações. A aquisição de imagem da tomografia computadorizada de feixe cônico (TCFC) surge como uma ferramenta de custo acessível, baixa exposição à radiação X e fidelidade de imagem, sem distorções e em tamanho real. Buscamos estabelecer a reprodução dos estudos graficométricos da Panorametria, proposta por Puricelli (2004), sobre imagens panorâmicas multiplanares adquiridas no modo MIP (Projeção de Intensidade Máxima), com o objetivo de comparar as diferenças entre as medidas lineares e angulares advindas da radiografia panorâmica convencional. Cinqüenta e quatro conjuntos de imagens panorâmicas convencionais e panorâmicas de TCFC, do mesmo paciente, foram avaliados. A Panorametria foi realizada através de traçados manuais, em ambos os filmes, por três examinadores. A reproductibilidade dos examinadores foi de ótima a excelente nas radiografias panorâmicas e de panorâmicas de TCFC (0,86±0,07 e 0,88±0,07, respectivamente). A magnificação total da radiografia panorâmica, para as medidas estudadas, foi de 4,3%, sendo maior no sentido vertical (12%) e horizontal inferior (11,5%) em comparação às medidas angulares das retas (6,7%) e horizontal superior (1,9%). Houve minimização angular em ambos os lados da radiografia panorâmica, em comparação a panorâmica de TCFC. Mais estudos são necessários para avaliar a panorâmica de TCFC adquirida no modo MIP, a fim de se conhecer mais sobre as suas características de reconstrução e distorção. / The panoramic radiograph, technical resultant of the projection of a rotational system, allows a wide view of the maxillofacial complex. Beyond the dental arches, fixed and articulated osseous structures, still offers anatomical images of orbital sockets, nasal fosses, maxillary sinus and airspaces. However, this auxiliary diagnosis mean presents limitations, mainly by means of distortions and magnifications. The Cone Beam Computed Tomography (CBCT) appears as a tool of accessible costs, low exposition to radiation X and image allegiance, without distortions and in real size. Aiming to establish a the reproduction of graphic and metrical studies of Panorametry, proposed by Puricelli (2004), on the multiplanar panoramic images acquired by MIP (Maximum Intensity Projection) mode, with the objective of comparing the differences between the linear and angular measurements from the conventional panoramic radiography. Fifty-four sets of conventional panoramic radiographs and CBCT panoramic MIP reconstructions, from the same patient, had been evaluated. The Panorametry was done by manually tracings, in both films, by three examiners. The correlation of the examiners was excellent in the panoramic radiographs and the CBCT panoramic MIP reconstructions (0,86±0,07 and 0,88±0,07, respectively). The total magnification of panoramic radiograph, for the studied measurements, was of 4,3%, being higher in the vertical direction (12%) and the horizontal inferior line (11,5%) in comparison to the angular measurements of the straight lines (6,7%) and the horizontal superior lines (1,9%). There was angular minimization in both sides of the panoramic radiograph, in comparison to the CBCT. More studies are necessary to evaluate CBCT panoramic MIP reconstructions, in order to know more about its characteristics of reconstruction and distortion.
10

Avaliação da reprodutibilidade na interpretação de imagens por ressonância magnética nuclear da articulação temporomandibular

Butzke, Karine Wagner January 2007 (has links)
Resumo não disponível.

Page generated in 0.0959 seconds