• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Randdichtheit und Randqualität von Kl. II-Füllungen aus einem Siloran bzw. konventionellen Kompositen unter Verwendung eines selbstkonditionierenden Dentinhaftvermittlers bei vorheriger selektiver Schmelzätzung in vitro / Microleakage and marginal integrity of class II restorations using a silorane compared to methacrylate-based resin composites luted with self-etch adhesives after phosphoric acid etching of enamel in vitro

Seidl, René January 2013 (has links) (PDF)
Die bei der Polymerisation adhäsiver Kompositrestaurationen unweigerlich auftretende Volumenschrumpfung und die damit verbundene Schrumpfungsspannung stellt ein bis heute grundlegendes Problem in der modernen Zahnerhaltung dar. Das Ziel dieser In-vitro-Untersuchung war es, die Randdichtheit und Randqualität von Klasse II - Füllungen aus dem schrumpfungsreduzierten Komposit FiltekTM Silorane mit denen konventioneller Komposite auf Methacrylatbasis unter Verwendung selbstkonditionierender Dentinhaftvermittler nach vorheriger selektiver Schmelzätzung zu vergleichen. Hierzu wurden 80 extrahierte, menschliche Molaren mit standardisierten MOD-Kavitäten versehen und mit Hilfe einer Mehrschichttechnik gefüllt. Trotz Verwendung von Self-Etch-Adhäsivsystemen (Silorane System Adhesive (3M ESPE), AdheSE® (Ivoclar Vivadent), ClearfilTM SE Bond (Kuraray), AdperTM ScotchbondTM SE (3M ESPE)) wurde zusätzlich eine selektive Schmelzätzung mit 35%iger Phosphorsäure für 30 Sekunden durchgeführt. Als Füllungsmaterialien kamen das auf der Siloranchemie basierende Hybridkomposit FiltekTM Silorane (3M ESPE), sowie die konventionellen, methacrylatbasierten Komposite Tetric EvoCeram® (ein Nano-Hybridkomposit, Ivoclar Vivadent), ClearfilTM AP-X (ein Hybridkomposit, Kuraray) und FiltekTM Supreme XT (ein Nanokomposit, 3M ESPE) zum Einsatz. Eine vierwöchige Wasserlagerung bei 37°C und ein 2500 Zyklen umfassendes Thermocycling (5°C vs. 55°C) dienten der künstlichen Alterung. Zur Bewertung der Randdichtheit und der Randqualität wurden die Proben bzw. Replika der Füllungsflächen einer Farbstoffpenetration und einer Analyse unter dem Rasterelektronenmikroskop unterzogen. Die ermittelten Daten wurden mit Hilfe der nicht-parametrischen Rangvarianzanalyse (Kruskal-Wallis-Test) und dem Multiplen Mittelwertvergleich nach Nemenyi bei einem Signifikanzniveau von P < 0,05 ausgewertet. Im Rahmen dieser Studie konnte kein signifikanter Unterschied bezüglich der Verwendung eines fließfähigen Komposits festgestellt werden. Desweiteren zeigte FiltekTM Silorane abschnittsunabhängig die geringsten Penetrationstiefen. Möglicherweise ist hierfür die deutlich geringere Polymerisationsschrumpfung gegenüber den anderen Kompositen verantwortlich. Hinsichtlich der Randqualität konnte FiltekTM Silorane jedoch nicht uneingeschränkt überzeugen. Während in den okklusalen und zervikalen Abschnitten noch überwiegend vergleichbare Ergebnisse erzielt wurden, zeigten sich insbesondere am axialen Füllungsrand häufiger Imperfektionen in Form von Randspalten. Möglicherweise ist das Silorane System Adhesive als essentielles Bindeglied aktuell noch nicht in der Lage eine ausreichende Haftwirkung am Zahn zu realisieren. Zusammenfassend lässt sich sagen, dass FiltekTM Silorane mit seiner ringöffnenden Polymerisation in Kombination mit einem funktionierenden Adhäsivsystem durchaus das Potential besitzt, den nächsten Schritt auf dem Weg zum schrumpfungsfreien Komposit zu gehen. Maßgeblich für den klinischen Erfolg eines Restaurationsmaterials sind neben einer geringen oder gar fehlenden Volumenkontraktion allerdings noch zahlreiche andere material-, patienten- und behandlerabhängige Faktoren. Auch die Entwicklung eines mit der Siloranchemie kompatiblen Flowables wäre aus Sicht vieler potentieller Anwender sicherlich wünschenswert. / PURPOSE: Polymerization shrinkage is still a great problem in modern dentistry. This study aimed to analyze the microleakage and marginal integrity of class II restorations using a silorane compared to methacrylate based resin composites luted with self-etch adhesives after enamel etching. METHODS: Eighty extracted caries-free human molars were used and evenly distributed into eight groups (N=10). Wide mod cavities were prepared in each molar. Four self-etching adhesives were used, after enamel etching with 35% phosphoric acid gel for 30 seconds. The adhesive materials were: Silorane System Adhesive (3M ESPE), AdheSE® (Ivoclar Vivadent), ClearfilTM SE Bond (Kuraray) and AdperTM ScotchbondTM SE (3M ESPE). The cavities were restored with a silorane-based microhybrid composite (FiltekTM Silorane (3M ESPE)) and three different methacrylate based composites (Tetric EvoCeram® (Ivoclar Vivadent), ClearfilTM AP-X (Kuraray), FiltekTM Supreme XT (3M ESPE)). Respectivly twenty cavities were filled with the same composite. One half with an additional flowable, one half without. The flowable composites were: FiltekTM Supreme XT Flowable (3M ESPE), Tetric EvoFlow® (Ivoclar Vivadent) and Clearfil MAJESTYTM Flow (Kuraray). Simulating clinical conditions the teeth were stored in water for four weeks at 37°C and subjected to 2500 thermal cycles of 5°C vs. 55°C in water with a 30-second dwell. After replicas were taken, two test procedures were carried out. Procedure A: a quantitative margin analysis in the scanning-electron microscopy (SEM) was performed at a magnification of 100 x using nine different criteria. Procedure B: the teeth were immersed in 50% AgNO3 solution at 37°C for two hours. Sectioned samples were examined under a stereomicroscope (EZ4 D, Leica Microsystems). Statistical analysis was performed with Kruskal-Wallis and Nemenyi’s test at 95% significance level. RESULTS: FiltekTM Silorane exhibited the lowest values of dye penetration. Compared with methacrylat based resin composites FiltekTM Silorane showed a comparable due of continuous margins. No statistically significant difference was observed between groups filled with the same composite with and without an additional flowable composite.
2

Randdichtheit und Randqualität von Kl. II-Füllungen aus einem Siloran bzw. methacrylatbasierten Kompositen unter Verwendung eines selbstkonditionierenden Dentinhaftvermittlers bei vorheriger Schmelz- und Dentinätzung in vitro / Micro-leakage and marginal integrity of class II restorations using a silorane compared to methacrylate-based resin composites luted with self-etch adhesives after phosphoric acid etching of enamel and dentine in vitro

Häfner [geb. Wagner], Daniela Claudia January 2017 (has links) (PDF)
Im Rahmen dieser In-vitro-Studie wurde Randdichtheit und Randqualität von plastischen Füllungsmaterialien aus einem schrumpfungsreduziertem Siloran (FiltekTM Silorane), zwei Hybridkompositen (Tetric EvoCeram® und ClearfilTM AP-X) und einem Nanokomposit (FiltekTM Supreme XT) mit den dazugehörigen Dentinadhäsivsystemen in Klasse II-Kavitäten mit einem von Schmelz und einem von Dentin begrenzten Füllungsrand untersucht. Obwohl die Hersteller die Dentinhaftvermittlermaterialien als selbstkonditionierend im Schmelz und Dentin vermarkten, wurde ein Total-Etching durchgeführt. Dessen Auswirkungen auf die Systeme sollte im Vergleich zu den früheren Arbeiten mit selektiver Schmelzätzung bzw. Selbstkonditionierung nach Herstellerangabe untersucht werden. An 80 extrahierenten dentes sapientes wurden Klasse II-Kavitäten nach Black präpariert, die eine Ausdehnung von 3,5 mm in vestibulo-oraler Richtung und eine okklusale Tiefe von 4 mm besaßen. Mesial wurde die okklusale Tiefe von 4 mm beibehalten, distal endete die Kavität an der Schmelz-Zement-Grenze. Die approximalen Schmelzränder wurden auf einer Breite von 1 mm angeschrägt. Die okklusal-zervikale Ausdehnung variierte je nach Ausdehnung der klinischen Krone zwischen 5 und 7 mm. In Inkrementtechnik wurden die Füllungen gelegt und ausgearbeitet. Die Materialien wurden wie folgt kombiniert: Silorane System Adhesive / FiltekTM Supreme XT / FiltekTM Silorane, Silorane System Adhesive / FiltekTM Silorane, AdperTM ScotchbondTM SE / FiltekTM Supreme XT Flow / FiltekTM Supreme XT Universalrestaurationsmaterial, AdperTM ScotchbondTM SE / FiltekTM Supreme XT Universalrestaurationsmaterial, ClearfilTM SE Bond / ClearfilTM AP-X, Clear-filTM SE Bond / Clearfil MajestyTM Flow / ClearfilTM AP-X, AdheSE® Bond / Tetric EvoFlow® / Tetric EvoCeram®, AdheSE® Bond / Tetric EvoCeram®. Nach 15-tägiger Lagerung in 0,9 %-iger Kochsalzlösung bei 37°C wurden die Proben einer Temperaturwechselbelastung (2500 Zyklen bei 5°C und 55°C, Verweilzeit 30 s) unterzogen. Im Anschluss an das Thermocycling erfolgte eine weitere 15-tägige Lagerung in Kochsalzlösung bei 37°C. Nach Herstellung von Replika zur Untersuchung der Randqualität unter dem Elektronenmikroskop wurde ein Farbstoffpenetrationstest zur qualitativen Randanalyse durchgeführt. Hierzu wurden die Zähne in 50 Gewichts-% AgNO3-Lösung eingelegt, belichtet und in zwei Ebenen (mesial-distal und bukkal-lingual) geschnitten. Die Auswertung erfolgt mit einem Auflichtmikroskop. Die statistische Auswertung erfolgte mit nicht-parametrischen Testverfahren wie dem Wilcoxon-Vorzeichen-Rang-Test und dem Kruskal-Wallis-Test. Unter-schiede zwischen den einzelnen Versuchsgruppen wurden mit dem multiplen Mittelwertsvergleich nach Nemenyi ermittelt. Das Signifikanzniveau war p<0,05. Filtek™ Silorane ist den anderen Kompositen nicht überlegen. Unabhängig vom verwendeten Material hat die Lage des Füllungsrandes im Zahn entscheidenden Einfluss auf die Randdichtheit und Randqualität bei Klas-se II-Füllungen. Die Anzahl der Randspalten und die Farbstoffpenetration sind okklusal am geringsten (im Mittel 2%), dafür aber der prozentuale Anteil der Überschüsse am größten (im Mittel 36%). Randdichtheit und Randqualität sind im Schmelz besser als im Dentin. Weder unter dem Elektronenmikroskop, noch unter dem Auflichtmikroskop, konnte ein Unterschied von statistischer Signifikanz zwischen der Verwendung und der Nichtverwendung eines Flowables zur Verbesserung der marginalen Integrität aufgezeigt werden. Das Hybridkomposit Tetric EvoCeram® schnitt beim Farbstoffpenetrationstest und der rasterelektronenmikroskopischen Untersuchung schlechter ab als das Filtek™ Silorane sowie als das Universalhybrid- und Nanokomposit. / Aim of this study was to analyse the micro-leakage and marginal integrity of class II restorations using a silorane compared to methacrylate-based resin composites luted with self-etch adhesives after phosporic acid etching of enamel and dentine in vitro. Eighty extracted human molars were used, divided into eight groups at ten molars. After preparing mod cavities, the teeth were filled with: Silorane Systeme Adhesive and FiltekTM Silorane, AdperTM ScotchbondTM SE and FiltekTM Supreme XT, ClearfilTM SE Bond and ClearfilTM AP-X, AdheSE® Bond and Tetric EvoCeram®. In four groups, an additional flowable was used. After artificial aging, a quantitative margin analysis was performed by means of a scanning electron microscope (SEM). After storage in AgNO3 solution, dye penetration was examinated under a stereomicroscope. Results: FiltekTM Silorane is not better than the other composites. Tetric EvoCeram® showed the highest values of dye penetration. No statistically significant difference was observed between groups filled with the same composite with and without an additional flowable composite. The location of the restorative junction in the tooth strongly influence the marginal integrity and quality.

Page generated in 0.0646 seconds