• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 3
  • Tagged with
  • 11
  • 10
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Investiga??o e gerenciamento de ?reas contaminadas por postos revendedores de combust?veis em Natal

Ramalho, Adriana Margarida Zanbotto 06 May 2013 (has links)
Made available in DSpace on 2014-12-17T14:09:17Z (GMT). No. of bitstreams: 1 AdrianaMSR_TESE.pdf: 15407461 bytes, checksum: 9724571238317c177c2fdb4b02772cad (MD5) Previous issue date: 2013-05-06 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Activities that have fuel subterranean storage system are considered potentially polluting fuels by CONAMA Resolution 273, due to the possibility of leak, outpouring and overflow of fuel into the ground. Being even more worrying when contaminate groundwater for public supply, as the case of Natal City. For this reason, the Public Ministry/RN, in partnership with UFRN, developed the project environmental suitability of Gas stations in Natal, of which 36% showed evidence of contamination. This paper describes the four stages of the management of contaminated areas: preliminary assessment of environmental liabilities, detailed confirmatory investigation of the contamination, risk analysis to human health (RBCA), as well as the remediation plan of degraded areas. Therefore it is presented a case study. For the area investigated has been proposed a mathematical method to estimate the volume of LNAPL by a free CAD software (ScketchUp) and compare it with the partition method for grid area. Were also performed 3D graphics designs of feathers contamination. Research results showed that passive benzene contamination in groundwater was 2791.77 ?g/L, when the maximum allowed by CONAMA Resolution 420 is 5 ?g/L which is the potability standards. The individual and cumulative risks were calculated from 4.4 x10-3, both above the limits of 1.0 x10-5 or by RBCA 1.0 x10-6 by the Public Ministry/RN. Corrective action points that remediation of dissolved phase benzene is expected to reach a concentration of 25 ?g/L, based on carcinogenic risk for ingestion of groundwater by residents residential, diverging legislation. According to the proposed model, the volume of LNAPL using the ScketchUp was 17.59 m3, while by the grid partitioning method was 14.02 m3. Because of the low recovery, the expected removal of LNAPL is 11 years, if the multiphase extraction system installed in the enterprise is not optimized / Atividades que possuem sistema de armazenamento subterr?neo de combust?veis s?o consideradas potencialmente poluidoras pela Resolu??o CONAMA 273/2000, devido ? possibilidade de vazamento, derramamento e transbordamento de combust?veis para o solo. Sendo ainda mais preocupante quando contaminam ?guas subterr?neas destinadas ao abastecimento p?blico, como o caso de Natal. Por este motivo, o Minist?rio P?blico/RN, em parceria com a UFRN, desenvolveu o projeto de adequa??o ambiental dos postos revendedores de combust?veis em Natal, dos quais 36% apresentaram ind?cios de contamina??o. Este trabalho descreve as quatro etapas do gerenciamento de ?reas contaminadas: avalia??o preliminar do passivo ambiental, investiga??o confirmat?ria detalhada da contamina??o, an?lise de risco a sa?de humana (RBCA), bem como o plano de remedia??o das ?reas degradadas. E apresenta um estudo de caso. Para a ?rea investigada ? proposto um m?todo matem?tico para estimar o volume de fase livre auxiliado por um software CAD livre (ScketchUp), este foi comparado com o m?todo de parti??o da ?rea por grid. Tamb?m s?o realizados os designs gr?ficos 3D das plumas de contamina??o. Os resultados da investiga??o de passivo mostraram que a contamina??o por benzeno na ?gua subterr?nea foi 2791,77 ?g/L, quando o m?ximo permitido pela Resolu??o CONAMA 420/2009 ? de 5 ?g/L que ? o padr?o de potabilidade. Os riscos individual e cumulativo calculados foram de 4,4x10-3, ambos acima dos limites aceit?veis pelo RBCA de 1,0x10-5 ou pelo Minist?rio P?blico/RN de 1,0x10-6. A a??o corretiva aponta que a remedia??o da fase dissolvida de benzeno dever? atingir uma concentra??o de 25 ?g/L, com base no risco carcinog?nico, para ingest?o de ?gua subterr?nea para moradores residenciais, divergindo da legisla??o. De acordo com o modelo proposto, o volume de fase livre utilizando o ScketchUp foi de ? de 17,59 m3, enquanto o m?todo de parti??o por grid foi de 14,02 m3. Devido ? baixa recupera??o, a previs?o de remo??o da fase livre ? de 11 anos, caso o sistema de extra??o multif?sica instalado no empreendimento n?o seja otimizado / 2020-01-01

Page generated in 0.0534 seconds