101 |
Some factors affecting the rate of chilling and the temperature distribution within the cold room of a multipurpose farm refrigeratorLarose, Paul Emile January 1948 (has links)
M.S.
|
102 |
Identification of sound transmission paths within a hermetic reciprocating refrigeration compressor via multiple-input/single-output modelingCraun, Matthew Ashby 19 September 2009 (has links)
Through the use of multiple-input/single-output (MISO) modeling, the propagation paths of sound within a reciprocating refrigeration compressor have been investigated and ranked. By investigating the nature of sound propagation within reciprocating compressors, it is hoped that compressor manufacturers can effectively formulate strategies for compressor sound reduction.
From experimental data of compressor far-field sound output, suspension spring forces, and internal pressure fluctuations, a MISO model has been developed. From this model, the importance of the suspension system to the compressor far-field sound spectrum has been identified. In the frequency range above 800 Hz, forces passing through the suspension system appear to be the dominant contributor to shell excitation and sound radiation.
Based upon this finding, it is recommended that modified suspension systems be considered as an avenue for compressor sound reduction efforts in the future. / Master of Science
|
103 |
Optimization of multiple chiller systemsOetjen, Michael Kent January 1984 (has links)
The following investigation describes the method used in minimizing the power consumption of multiple chiller systems by determining not only the most efficient combination of chillers in the system but also the optimal operating levels of each chiller making up the combination. The general mathematical formulation for a system of N chillers with arbitrary performance characteristics is solved and applied to the special case of chillers having parabolic performance characteristics. The analysis is then applied to various two and six chiller systems using performance characteristics of centrifugal chillers in order to show the optimal operating conditions and to illustrate the potential energy savings of multiple chiller systems compared to a single chiller system. The effects of various combinations of chillers and the effects of entering condenser water temperature are systematically investigated. A particular six chiller combination, corresponding to portions of the existing chiller systems at Virginia Tech, is also investigated. / Master of Science
|
104 |
Design of an ultra-low temperature robotStafford, Roland T. 01 April 2002 (has links)
No description available.
|
105 |
Experimental and numerical analysis of axial flow fansAugustyn, Ockert Philippus Hermanus 12 1900 (has links)
Thesis (MScEng)--Stellenbosch University, 2013. / ENGLISH ABSTRACT: The majority of power stations in South Africa are located in coal rich, but arid
regions where wet-cooled condenser systems are not feasible from an
environmental and economic perspective. Consequently the focus on power
generation cooling has shifted towards dry-cooling systems using air-cooled
steam condensers (ACSC). The steam passing through the ACSC units is cooled
by an air-draught, mechanically induced by large diameter axial flow fans.
Consequently the effectiveness of the cooling is impacted by the performance of
these fans, which ultimately affects the overall efficiency of the power plant.
However, due to the large diameters (> 10 m) of these fans, their performance is
predicted based on small scale test results using the fan scaling laws.
The objective of this project was to develop a methodology which accurately
predicts the fan performance of more than one fan configuration using
computational fluid dynamics (CFD) software and validating the results with
experimental tests. Four fans were considered in this study of which three were
scaled fan models of large air-cooled axial fans. The performance of the scaled
fan models (L1-, L2- and N-fan) were measured in a type A, BS 848 standard fan
test facility. The geometries of the fans were scanned three-dimensionally to
obtain the models for simulation purposes. The other fan considered was an 8-
bladed axial fan designed by Bruneau (1994) and referred to as the B-fan.
Simulations were carried out for the L2-, N- and B-fan for different computational
domains while implementing the multiple reference frames (MRF) and steady
RANS approach. Three variations of the k-ε turbulence model were also
investigated.
Noticeable differences were found between the experimental and numerical
results of the B-fan. Good correlations between the numerical and experimental
fan static pressure, fan power and fan static efficiency were found for the two
scaled model fans over a large operating range. The performance of the full scale
fans, however, did not correlate well with the performance of the scaled models. It
is concluded that accurate simulations of axial fans are possible although these
domains require a large number of mesh elements. It is recommended that further
research is carried out to investigate the relationship between full scale and small
scale fan models. / AFRIKAANSE OPSOMMING: Die meerderheid steenkool kragstasies in Suid-Afrika is geleë in droë, maar
steenkool ryke streke waar natverkoelde kondensor stelsels uit ʼn omgewings en
ekonomiese perspektief nie geskik is nie. Die fokus in kragopwekking verkoeling
het dus verskuif na droë-verkoelings stelsels en spesifiek die gebruik van
lugverkoelde stoomkondensors (LVSKs). Die stoom in LVSK eenhede word
verkoel deur atmosferiese lug wat meganies geïnduseer word deur groot
aksiaalvloeiwaaiers. Die effektiwiteit van die verkoelingsproses word gevolglik
beïnvloed deur die werksverrigting van hierdie waaiers wat uiteindelik die
algehele effektiwiteit van die kragstasie beïnvloed. As gevolg van hierdie waaiers
se grootte word hulle werksverrigting egter bepaal op grond van kleinskaal
toetsresultate en deur gebruik te maak van die waaierskaleringswette.
Die hoofdoelwit van hierdie projek was om ‘n metodiek te ontwikkel wat die
werksverrigting van ʼn aksiaalwaaier akkuraat kan voorspel vir ʼn verskeidenheid
opstellings, deur gebruik te maak van berekenings vloei meganika (BVM)
sagteware en die resultate eksperimenteel te verifieer. Die projek het vier waaiers
ondersoek waarvan drie van hierdie waaiers geskaleerde modelle van groot
lugverkoelde aksiaalwaaiers was. Die werksverrigting van die geskaleerde
waaiers (L1-, L2- en N-waaier) was met ‘n tipe A, BS 848 standaard waaier
toetsfasiliteit gemeet. Die geometrie van dié waaiers was ook drie-dimensioneel
opgemeet vir simulasie doeleindes. Die B-waaier, ‘n 8 lem aksiaalwaaier, wat
ontwerp is deur Bruneau (1994) was slegs numeries ondersoek. Die L2-, N- en Bwaaier
was gesimuleer in verskillende berekeningsdomeine deur gebruik te maak
van die multi verwysingsraamwerk en gestadigde vloeiberekenings benaderings.
Drie k-ε turbulensie modelle was ook ondersoek.
Merkbare verskille tussen die eksperimentele en numeriese resultate van die Bwaaier
was waargeneem. Goeie korrelasie tussen die eksperimentele en numeriese
resultate van die geskaleerde waaiers vir ‘n wye bedryfsbestek was gevind. ‘n
Vergelyking tussen die volskaal en kleinskaal waaiers se werksverrigting het egter
beduidende afwykings aangetoon. Deur gebruik te maak van ‘n groot aantal selle
in die berekeningsdomein was dit moontlik om ʼn verskeidenheid
aksiaalvloeiwaaiers akkuraat te simuleer. Verdere navorsing wat die verhouding
tussen volskaal en kleinskaal waaiers ondersoek woord aanbeveel.
|
106 |
A subcritical and transcritical carbon dioxide refrigeration system utilizing multiple expansion devicesFourie, Marna 04 1900 (has links)
Thesis (MScEng)--Stellenbosch University, 2014. / ENGLISH ABSTRACT: Carbon dioxide is a natural gas that has been used as a refrigerant as far back as the 1850s. It was then primarily used because it was easily obtainable and non-toxic. Due to the high operating pressure and relatively low critical temperature (and high critical pressure) of CO2, it was gradually phased out and replaced with hydrochlorofluorocarbons and chlorofluorocarbons. With the discovery of the greenhouse effect, greenhouse gasses and ozone depleting gasses, the Montreal Protocol and the Kyoto Protocol were placed into effect. These two protocols call for the reduction in use of certain greenhouse gasses and the complete exclusion of others. The focus turned to natural gasses that are more environmentally friendly and easier to come by. Carbon dioxide is one such gas. However, CO2 has a low critical temperature and high pressure, 33.98 °C and 73.77 bar respectively. CO2 refrigeration systems are more effective, have a greater coefficient of performance and have a greater operating temperature difference (over the gas-cooler) when used under transcritical conditions. It is preferred to have transcritical CO2 refriger-ation systems. The drawback of such a system is the extreme operating conditions. A special system must be designed, built and commissioned at the University of Stellenbosch. The system will demand the use or manufacture of unique, special-ised components. Most of the components utilised are extremely expensive and/or difficult to come by, or designed and manufactured specifically for this system.
The CO2 system at the University of Stellenbosch is exceptional and stands out from conventional systems in that: - it can operate under both the subcritical and transcritical conditions;
- it has multiple expansion units, which can be alternated, giving a total of four different operating configurations;
- the system can run with fully automated controllers or as a static system;
- the internal heat exchanger can be included or excluded from the system;
- all the heat exchangers can run in counter flow or parallel flow; and
- The system has multiple testing points, for both temperature and pressure, to give the operator accurate measurements to be used in comparison with design software, etc. Three simulation programs are given that describe the physical system. The first simulation program is a steady-state simulator used to aid in the design of the heat exchangers and the capillary tube. The second simulator is a steady-state program that determines the mass flow rate in the capillary tube. The third simulation is a transient program, programmed to determine the steady-state conditions of a sys-tem, given set initial conditions and a transient start-up. / AFRIKAANSE OPSOMMING: Koolstofdioksied is 'n natuurlike gas wat gebruik word as 'n verkoelingsmiddel so ver terug as die 1850's. Dit is toe hoofsaaklik gebruik omdat dit maklik verkrygbaar en nie giftig is nie. As gevolg van die hoë werksdruk en relatief lae kritiese temperatuur (en hoë kritiese druk) van CO2, is dit geleidelik uitgefaseer en vervang met hidrochloorfluoorkoolstof en chloorfluoorkoolstowwe. Met die ontdekking van die kweekhuiseffek, kweekhuisgasse en osoon-afbrekende gasse, is die Montreal-protokol en die Kyoto-protokol in werking gestel. Hierdie twee protokolle vereis die afname in die gebruik van sekere kweekhuisgasse en die algehele uitsluiting van ander. Die fokus het verskuif na natuurlike gasse wat omgewingsvriendeliker en makliker is om te bekom. Koolstofdioksied is so 'n gas. Maar CO2 het 'n lae kritiese temperatuur en hoë kritiese druk, 33.98 °C en 73.77 bar onderskeidelik. CO2 verkoelingstelsels is meer effektief, het 'n groter koëffisiënt van werksverrigting en het 'n groter bedryfstemperatuur-verskil (oor die gas-verkoeler) wanneer dit gebruik word onder transkritiese toestande. Dit is dus verkieslik om transkritiese CO2 verkoelingstelsels te hê. Die nadeel van so 'n stelsel is die relatief uiterste bedryfstoestande. 'n Spesiale stelsel moet ontwerp word, dikwels met die gebruik of vervaardiging van unieke, hoogs gespesialiseerde komponente. So 'n stelsel is ontwerp vir die Universiteit van Stellenbosch. Die meeste van die komponente wat gebruik is, is baie duur en/of moeilik om te bekom, of is spesifiek ontwerp en vervaardig vir hierdie stelsel.
Die CO2-stelsel by die Universiteit van Stellenbosch is uitsonderlik en staan uit bo konvensionele stelsels deurdat:
- dit kan funksioneer onder beide subkritiese en transkritiese toestande;
- dit verskeie gasuitsettings-eenhede het, wat afgewissel kan word, wat 'n totaal van vier verskillende bedryfskonfigurasies gee;
- die stelsel bedryf kan word met volle outomatiese beheerders of as 'n statiese stelsel;
- die interne hitte-uitruiler óf in-, óf uitgesluit kan word van die stelsel;
- al die hitte-uitruilers bedryf kan word in kontra-vloei of parallelle vloei; en
- die stelsel verskeie toetspunte het, vir beide temperatuur en druk, wat die operateur akkurate metings gee om te vergelyk met die ontwerp sagteware, ens., wat gebruik word. Drie gegewe simulasieprogramme beskryf die fisiese stelsel. In een simulasie word 'n bestendige toestand-simulator gebruik om te help met die ontwerp van die hitteruilers en die kapillêre buis. Die tweede simulasie program is 'n bestendige toestands-program wat die algehele vloeitempo in die kapillêre buis bepaal. Die laaste simulasie is 'n vlugtige program, geprogrammeer om die tydelike toestande van 'n stelsel te bepaal, gegewe vasgestelde aanvanklike toestande en 'n kortstondige aanskakeling.
|
107 |
Air-cooled heat exchangers and cooling towers : thermal-flow performance evaluation and designKroger, Detlev G. 12 1900 (has links)
Thesis (PhD)--Stellenbosch University, 2004. / ENGLISH ABSTRACT: During the last 30 years I have been involved in the theory and practice of thermal engineering and
in particular, in the areas of air-cooled heat exchangers and cooling towers for the power,
refrigeration, process and petrochemical industries in South Africa and internationally. During this
period, I have authored and co-authored more than 120 papers that were published in technical
journals or presented at conferences nationally or internationally. Most of these papers are included
in a manuscript entitled "Air-cooled Heat Exchangers and Cooling Towers", in which Ipresent a
systematic approach to the thermal performance evaluation and design of industrial air-cooled heat
exchangers and cooling towers. This original publication also includes the relevant practice
applicable to the design of cooling systems, based on my experience as a consultant to industry.
Design offices throughout the world presently follow our design methods, or at least employ many
of our research results. Our work has furthermore contributed to the development of improved
cooling system designs (e.g. new dephlegmator header designs), components (e.g. single-row
flattened finned tubes) and product improvement and quality control (e.g. performance testing and
measurement of thermal contact resistance between fin and tube during production). Many of our
research findings have found application in the modification of existing cooling systems. The
manuscript has also been used as reference work during the presentation of short courses to
practising engineers and consultants in industry and to engineering graduates at the University of
Stellenbosch.
A two-volume edition of this manuscript was published by PennWell Corp., Tulsa, Oklahoma, USA
in 2004. / AFRIKAANSE OPSOMMING: Gedurende die laaste 30 jaar was ek betrokke by die teorie en praktyk van lugverkoelde warmteoordraers
en koeltorings vir die kragopwekkings-, verkoelings-, proses- en petro-chemiesenywerhede
in Suid-Afrika sowel as in die buiteland. Gedurende hierdie periode was ek outeur en
mede-outeur van meer as 120 publikasies wat in tegniese tydskrifte, of by plaaslike of oorsese
konferensies aangebied is. Die meeste van hierdie publikasies vorm deel van 'n manuskrip getiteld
"Air-cooled Heat Exchangers and Cooling Towers" waarin ek 'n sistematiese benadering tot die
bepaling van die termiese vermoë en ontwerp van industriële lugverkoelde warmteoordraers en
koeltorings aanbied. Hierdie oorspronklike publikasie bevat ook die relevante praktyk wat van
toepassing is op verkoelingsaanlegte. Ontwerpkantore wêreldwyd volg tans hierdie
ontwerpsmetodes, of gebruik ten minste baie van ons navorsingsresultate. Ons werk het verder
bygedra tot die ontwikkeling van verbeterde verkoelingsaanlegte (bv. nuwe deflegmatore),
komponente (bv. enkelbuisry platvinbuise ) en verbeterde produkte en kwaliteitskontrole
(bv. toetsing van verkoelingsvermoë oftermiese kontakweerstand tussen vin en buis gedurende
produksie). Baie van ons bevindinge het toepassing gevind in die modifikasie van
verkoelingsaanlegte. Die manuskrip is ook as verwysing gebruik gedurende die aanbieding van
kort kursusse aan ingenieurs in die praktyk en aan nagraadse studente aan die Universiteit van
Stellenbosch.
'n Twee-volume uitgawe van die manuskrip is deur PennWell Corp., Tulsa, Oklahome, VSA in
2004 gepubliseer.
|
108 |
Computer simulation of transient refrigeration load in a cold storage for apples and pearsAdre, Norberto 31 July 1987 (has links)
Increased consumer demand for fresh fruit throughout
the year has created a need for long term storage. Long
term storage of fruit uses more energy than fresh market
products, thus increasing production cost. Pacific
Northwest energy costs and more competition for markets
has made energy conservation an important factor to be
considered by the fruit industry. A BASICA computer
program, RLSIM, was developed to predict the transient
refrigeration load throughout the storage season in apple
and pear cold storage warehouses. RLSIM accurately
predicted the seasonal and component refrigeration system
energy demand curves during the 1985-1986 cold storage
season. The results also indicated that the largest single
energy use component is the continuous operation of
evaporator fans. Simulation of a six hours on and six hours off fan cycling technique indicated a reduction of 23.75 percent could be achieved in overall refrigeration
system energy use in the cold storage warehouse. Cold
storage warehouse management can be improved by using the
results of RLSIM. Fan cycling schemes could be properly
employed without risk of increasing fruit temperature.
Recommendations were made to update research in areas of
cooling and respiration rates of various fruits in both
controlled atmosphere and common storage. / Graduation date: 1988
|
109 |
Waste minimisation at an air-conditioning company.January 2003 (has links)
Waste minimisation involves reducing waste (emissions, effluent, solid waste) in companies, at source. v 7, 8 Its benefits include cost savings, environmental improvement, increased throughput and risk and liability reduction. 7, 8, 13 Through implementation of a structured waste minimisation programme, companies can identify waste minimisation
opportunities: broad focus areas that will benefit from a more detailed waste minimisation assessment. More specific waste minimisation solutions can then be identified. In this study, the waste minimisation opportunity was identified by the company, Ben Booysen, a priori. Ben Booysen is a local air-conditioning and refrigeration company in Pietermaritzburg, which services air-conditioner units. They identified the waste minimisation opportunity of optimising the process conditions for cleaning the airconditioner units. At the time at Ben Booysen, Alukleen, an acid cleaner (RT Chemicals®, RTCM 64) , was applied manually (by a paintbrush) at an effective dilution of 1:3 to clean the aluminium air-conditioner coils. Handy Andy and green soap were used to clean the plastic covers of the units. Concerns about the effluent, cost and safety of handling Alukleen led to their identification of this waste minimisation opportunity. The initial objectives of this project were thus the qualification and quantification of the species present in Alukleen; the quantification of the species present in the Ben Booysen effluent and the subsequent comparison of these values to limits for disposal to stormwater and Darvill. A further objective was the optimisation of the cleaning system with regard to Alukleen concentration and contact (soaking) time. Wet chemical analysis was employed as a qualitative tool for identification of the components present in Alukleen. This analysis indicated that fluoride, sulfate, sulfide, arsenite and chloride ions are present in Alukleen. Further quantitative analysis using the
Ion chromatograph, the ICP-OES and a fluoride ion selective electrode indicated that only sulfate (152600 ppm) and fluoride (25400 ppm) are present in significant quantities. Studies were conducted on aluminium coil pieces in which both the contact (soaking) times and Alukleen concentrations were varied. These tests indicated that the effect of
soaking time on the cleanliness achieved was negligible. Although a greater amount of dirt was removed when using more concentrated Alukleen solutions, etching of the metal occurred at higher concentrations, resulting in a loss of sheen and malleability of the metal. Etching of the aluminium air-conditioner coils by Alukleen, as indicated by both digital photography and electron microscopy, resulted in extending the objectives of this project
to include the investigation of alternative aluminium cleaners. Hence, the cleaning action of three degreasers was investigated: Powerkleen (RT Chemicals®, RTCMI23), Technicians' Choice (Auto Brite (PTY) Ltd.) and Klengine (Auto Brite (PTY) Ltd.) . Powerkleen was found to be the most effective degreaser and did not compromise the metal's sheen or malleability. Further studies were then conducted to characterise the
major components ofPowerkleen and to optimise its use with regard to concentration and contact (soaking) time. The suitability oftwo methods of application was also tested. The main component of Powerkleen, determined through the use of ICP-OES, was found to be potassium hydroxide, present at a concentration of 0.711 M. The optimum Powerkleen concentration range for cleaning the aluminium coils was found to be between a 1:20 and 1:40 dilution. Contact (soaking) time of Powerkleen with the aluminium coils was found to have a negligible effect on the mass of dirt removed by the degreaser. Application of the Powerkleen to the aluminium coils by an air gun at a pressure of 4 bars (for units serviced at Ben Booysen) and by a pump bottle (for units serviced in industry) were both found to achieve an acceptable degree of cleanliness of the aluminium.
A feasibility analysis (technical , economical and environmental) indicated that a 1:40 dilution of Powerkleen is a feasible, cost-effective and environmentally compliant alternative to Alukleen. Implementation of the Powerkleen cleaning system would result in a R5030 annual saving with a payback period of 5.9 months and an internal rate of return of 214.9%. It would further eliminate the fluoride effluent problems associated with Alukleen and reduce the quantity of chemical raw materials required for the process from 2100 Llannum to 260 Llannum. In industry, an effective dilution of 1:39 would be used for the sake of eas y dilution. A 1:79 dilution of Powerkleen was also found to be a feasible replacement for Handy Andy and green soap in the cleaning of the plastic covers of the units. / Thesis (M.Sc.)-University of Natal, Pietermaritzburg, 2003.
|
110 |
Convective instability of oscillatory flow in pulse tube cryocoolers due to asymmetric gravitational body forceMulcahey, Thomas Ian 22 May 2014 (has links)
Pulse tube cryocoolers (PTCs) are among the most attractive choices of refrigerators for applications requiring up to 1 kW of cooling in the temperature range of 4-123 K as a result of the high relative efficiency of the Stirling cycle, the reliability of linear compressors, and the lack of cryogenic moving parts resulting in long life and low vibration signature. Recently, PTCs have been successfully used in applications in the 150 K range, extending the useful range of the device beyond the traditional cryogenic regime. A carefully designed cylindrical cavity referred to as the pulse tube replaces the mechanical expander piston found in a Stirling machine. A network consisting of the pulse tube, inertance tube, and surge volume invoke out-of-phase pressure and mass flow oscillations while eliminating all moving parts in the cold region of the device, significantly improving reliability over Stirling cryocoolers. Terrestrial applications of PTCs expose a fundamental flaw. Many PTCs only function properly in a narrow range of orientations, with the cold end of the pulse tube pointed downward with respect to gravity. Unfavorable orientation of the cold head often leads to a catastrophic loss of cooling, rendering the entire cryocooler system inoperable. Previous research indicates that cooling loss is most likely attributed to secondary flow patterns in the pulse tube caused by free convection. Convective instability is initiated as a result of non-uniform density gradients within the pulse tube. The ensuing secondary flow mixes the cryogen and causes enhanced thermal transport between the warm and cold heat exchangers of the cryocooler.
This study investigates the nonlinear stabilizing effect of fluid oscillation on Rayleigh-Bénard instability in a cryogenic gas subject to misalignment between gravitational body force and the primary flow direction. The results are directly applicable to the flow conditions frequently experienced in PTCs. Research has shown that the convective component can be minimized by parametrically driven fluid oscillation as a result of sinusoidal pressure excitation; however, a reliable method of predicting the influence of operating parameters has not been reported. In this dissertation, the entire PTC domain is first fully simulated in three dimensions at various angles of inclination using a hybrid method of finite volume and finite element techniques in order to incorporate conjugate heat transfer between fluid domains and their solid containment structures. The results of this method identify the pulse tube as the sole contributor to convective instability, and also illustrate the importance of pulse tube design by incorporating a comparison between two pulse tubes with constant volume but varying aspect ratio. A reduced domain that isolates the pulse tube and its adjacent components is then developed and simulated to improve computational efficiency, facilitating the model’s use for parametric study of the driving variables. A parametric computational study is then carried out and analyzed for pulse tubes with cold end temperatures ranging from 4 K to 80 K, frequencies between 25-60 Hz, mass flow - pressure phase relationships of -30◦ and +30◦, and Stokes thickness-based Reynolds numbers in the range of 43-350, where the turbulent transition occurs at 500.
In order to validate the computational models reported and therefore justify their suitability to perform parametric exploration, the CFD codes are applied to a commercially developed single stage PTR design. The results of the CFD model are compared to laboratory-measured values of refrigeration power at temperatures ranging from 60 K to 120 K at inclination angles of 0◦ and 91◦. The modeled results are shown to agree with experimental values with less than 8.5% error for simulation times of approximately six days using high performance computing (HPC) resources through Georgia Tech’s Partnership for Advanced Computing (PACE) cluster resource, and 10 days on a common quad-core desktop computer. The results of the computational parametric study as well as the commercial cryocooler data sets are compiled in a common analysis of the body of data as a whole. The results are compared to the current leading pulse tube convective stability model to improve the reliability of the predictions and bracket the range of losses expected as a function of pulse tube convection number. Results can be used to bracket the normalized cooling loss as a function of the pulse tube convection number NPTC. Experimental data and simulated results indicate that a value of NPTC greater than 10 will yield a loss no greater than 10% of the net pulse tube energy flow at any angle. A value of NPTC greater than 40 is shown to yield a loss no greater than 1% of the net pulse tube energy flow at all angles investigated.
The computational and experimental study completed in this dissertation addresses static angles of inclination. Recent interest in the application of PTCs to mobile terrestrial platforms such as ships, aircraft, and military vehicles introduces a separate regime wherein the angle of inclination is dynamically varying. To address this research need, the development of a single axis rotating cryogenic vacuum facility is documented. A separate effects apparatus with interchangeable pulse tube components has also been built in a modular fashion to accommodate future research needs.
|