• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Implementation of Accelerometer-Based Adaptive Noise Cancellation in a Wireless Wearable Pulse Oximeter Platform for Remote Physiological Monitoring and Triage

Comtois, Gary W. 31 August 2007 (has links)
"A wireless wearable battery-operated pulse oximeter has been developed in our laboratory for field triage applications. The wearable pulse oximeter, which uses a forehead-mounted sensor to provide arterial oxygen saturation (SpO2) and heart rate (HR) information, would enable field medics to monitor vital physiological information following critical injuries, thereby helping to prioritize life saving medical interventions. This study was undertaken to investigate if accelerometry (ACC)-based adaptive noise cancellation (ANC) is effective in minimizing SpO2 and HR errors induced during jogging to simulate certain motion artifacts expected to occur in the field. Preliminary tests confirmed that processing the motion corrupted photoplethysmographic (PPG) signals by simple Least-Mean-Square (LMS) and Recursive Least-Squares (RLS) ANC algorithms can help to improve the signal-to-noise ratio of motion-corrupted PPG signals, thereby reducing SpO2 and HR errors during jogging. The study showed also that the degree of improvement depends on filter order. In addition, we found that it would be more feasible to implement an LMS adaptive filter within an embedded microcontroller environment since the LMS algorithm requires significantly less operations."
2

Wearable Forehead Pulse Oximetry: Minimization of Motion and Pressure Artifacts

Dresher, Russell Paul 03 May 2006 (has links)
Although steady progress has been made towards the development of a wearable pulse oximeter to aid in remote physiological status monitoring (RPSM) and triage operations, the ability to extract accurate physiological data from a forehead pulse oximeter during extended periods of activity and in the presence of pressure disturbances acting on the sensor remains a significant challenge. This research was undertaken to assess whether the attachment method used to secure a pulse oximeter sensor affects arterial oxygen saturation (SpO2) and heart rate (HR) accuracy during motion. Additionally, two sensor housings were prototyped to assess whether isolating the sensor from external pressure disturbances could improve SpO2 and HR accuracy. The research revealed that measurement accuracy during walking is significantly affected by the choice of an attachment method. Specifically, the research indicated that an elastic band providing a contact pressure of 60 mmHg can result in decreased measurement error and improved reliability. Furthermore, the research validated that the two isolating housings we have investigated improve SpO2 and HR errors significantly at pressures as high as 1200 mmHg (160 kPa) compared to current commercial housings. This information may be helpful in the design of a more robust pulse oximeter sensor for use in RPSM.

Page generated in 0.1284 seconds