• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Confiabilidade intra e interobservador da análise da mobilidade diafragmática pelo método radiográfico / Intra and interobserver reability of the analysis of diaphragmatic mobility by the radiographic method

Saltiél, Rossana Von 01 December 2011 (has links)
Made available in DSpace on 2016-12-06T17:06:46Z (GMT). No. of bitstreams: 1 Rossana von Saltiel.pdf: 785136 bytes, checksum: 450fa73958d2b1db3cf60cbd2ad7d229 (MD5) Previous issue date: 2011-12-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Objective: Radiographic measure reliability analyzed as mobility assessment method of the right and left hemi-diaphragms in adults. Methods: It was selected 42 in-patients to be submitted to cholecystectomy. The study participants were assessed according to the following parameters: physical exam for measuring the cardio-respiratory signals and anthropometric variables, pulmonary function tests and mobility radiographic assessment of right and left hemi-diaphragm. The radiographic measure of the cranial-caudal mobility of each hemi-diaphragm was determined by the distance between the respective hemi-domes, when the maximum breath in and breath out were taken by two physiotherapist (observer A and B) in an independent way in two distinct intervals (1st and 2nd assessment). The reproducibility intra and inter-observers of the radiographic measure were determined by the intra-class correlation coefficient (ICC[ 2,1]) by the reliability interval (IC) of 95%. The graphic disposition of Bland & Altman was also used by allowing better concordance visualization between the measures. The significance level adopted for the statistic treatment was 5% (p<0.05). Results: In the analyses of intra-observer reproducibility, the ICC[2.1] indicated very high correlation for the observer A as for radiographic assessment of the right hemi-diaphragm as for the left (ICC[2.1] = 0.99, p<0.001 and ICC[2.1]=0.97 p<0.001, respectively) and also for observer B (ICC[2.1]=0.99, p<0.001 and ICC[2.1] = 0.99 p<0.001, respectively). In the analyses of inter-observer reproducibility, the ICC[2.1] indicated very high correlation as for the 1st as for the 2nd radiographic assessment for the right hemi-diaphragms (ICC[2.1] = 0.98 and ICC[2.1] = 0.99, respectively, p<0.001) and left (ICC[2.1] = 0.98 and ICC[2,1] = 0.99, respectively, p<0.001). Conclusion: The mobility intra and inter-observer exams of the right and left hemi-diaphragm, through the radiographic method presented high reliability. The technique is of easy application and supplies the practical clinic a reliable method for measuring the diaphragm mobility. / Objetivo: Analisar a confiabilidade da medida radiográfica como método de avaliação da mobilidade dos hemidiafragmas direito e esquerdo em indivíduos adultos. Métodos: Foram selecionados 42 pacientes que estavam internados para serem submetidos à colecistectomia. Os participantes do estudo foram avaliados segundo os seguintes parâmetros: exame físico para mensuração dos sinais cardiorrespiratórios e das variáveis antropométricas, prova de função pulmonar e avaliação radiográfica da mobilidade dos hemidiafragmas direito e esquerdo. A medida radiográfica da mobilidade crânio-caudal de cada hemidiafragma foi determinada pela distância entre as respectivas hemicúpulas quando em inspiração e expiração máximas por dois fisioterapeutas (observador A e B), de forma independente, em dois momentos distintos (1a e 2a avaliação). A reprodutibilidade intra e interobservadores das medidas radiográficas foram determinadas pelo coeficiente de correlação intraclasse (ICC[2,1]) e pelo intervalo de confiança (IC) de 95%. A disposição gráfica de Bland & Altman também foi utilizada por permitir melhor visualização da concordância entre as medidas. O nível de significância adotado para o tratamento estatístico foi de 5% (p<0,05). Resultados: Na análise da reprodutibilidade intraobservador, o ICC[2,1] indicou correlação muito alta para o observador A tanto na avaliação radiográfica do hemidiafragma direito quanto do esquerdo (ICC[2,1] = 0,99, p<0,001 e ICC[2,1] = 0,97 p<0,001 respectivamente) e também para o observador B (ICC[2,1] = 0,99, p<0,001 e ICC[2,1] = 0,99 p<0,001 respectivamente). Na análise da reprodutibilidade interobservadores, o ICC[2,1] indicou correlação muito alta tanto para a 1ª quanto para a 2ª avaliação radiográfica dos hemidiafragmas direito (ICC[2,1] = 0,98 e ICC[2,1] = 0,99, respectivamente, p<0,001) e esquerdo (ICC[2,1] = 0,98 e ICC[2,1] = 0,99, respectivamente, p<0,001). Conclusão: Os exames intra e interobservadores da mobilidade dos hemidiafragmas direito e esquerdo, por meio do método radiográfico, apresentaram alta confiabilidade. A técnica é de fácil aplicação e fornece à prática clínica um método confiável para mensurar a mobilidade diafragmática.

Page generated in 0.1179 seconds