• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The Fc Orth (SA) final examination The short-term outcome of hip revision arthroplasty with Trabecular Metal™ components and augments

Noconjo, Lubabalo 15 September 2021 (has links)
Background: Highly porous Trabecular Metal™ acetabular components are increasingly being used in revision hip arthroplasty as they facilitate ingrowth, provide a useful mechanism to deal with bone loss and may decrease the risk of infection. The purpose of this audit was to describe: 1) the short-term radiological outcomes of revision hip arthroplasty with Trabecular Metal™ components and augments. 2) the total number of hip arthroplasty surgeries over five years, and indications for revision. Methods: A retrospective folder and radiograph review of all patients who had revision total hip arthroplasty (THA) at a tertiary level hospital from February 2012 to February 2017 was done. Results: There were 979 THAs performed over the period – 863 (87%) primary THAs, and 116 (12%) hip revision cases performed in 107 patients. Of the 116 (107 patients) hip revisions, there were seven (6%) re-revisions in five patients. Trabecular Metal™ was used for revision in 16 hips (14 patients), which is 13.7% of the total 116 revisions. There were ten females and four males with an average age of 61 years. The average duration of follow-up in this group was 18.5 months (1.5– 39.2). In these 16 Trabecular Metal™ hips, there were three (18.7%) early failures of fixation due to technical errors. The indications for revision were aseptic loosening 67 (58.6%), septic loosening 11 (9.5%), liner wear 18 (15.5%), periprosthetic fracture five (4.3%), other 15 (13%). Conclusion: In our institution, Trabecular Metal™ revisions had a 18.7% early failure rate due to technical error. 12% of the arthroplasty is revision surgery. The indications for revision are similar to published literature.
2

Global Joint Registry: Analysis of Revision Hip Arthroplasty Data

Runser, Alicia M. January 2020 (has links)
No description available.

Page generated in 0.0842 seconds