• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 1
  • Tagged with
  • 13
  • 13
  • 9
  • 9
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análisis de riesgo sísmico de colegios públicos de San Juan de Miraflores mediante la metodología de Rapid Visual Screening y evaluación del desempeño sísmico con análisis no-lineales del pabellón 780 Pre

Cardenas Angeles, Omar Percy, Farfán Bonett, Aaron Gabriel 16 January 2021 (has links)
Perú se localiza en una zona de alta sismicidad, debido a que se encuentra encima del área de subducción entre la placa tectónica de Nazca y Sudamericana, perteneciente al cinturón de fuego del Pacífico. Perú es un país en vía de desarrollo, por lo que es de suma importancia estar preparados para auxiliar a los miles de damnificados que pueda haber ante un evento sísmico importante. La evaluación del riesgo sísmico de edificaciones esenciales como colegios y hospitales es necesario para trabajos de reforzamiento estructural en este tipo de infraestructura. En el presente artículo científico, se presenta cuán vulnerables son los colegios públicos del distrito de San Juan de Miraflores en la ciudad de Lima ante un evento sísmico. Para ello, se utilizó la metodología de Inspección Visual Rápida del FEMA P-154. Además, se analizó de forma cuantitativa el pabellón 780 Pre, un módulo educativo estandarizado y construido en los años noventa cuya presencia es frecuente en dicho distrito. Para ello, se realizó un análisis no-lineal estático y no-lineal dinámico. Los resultados de la investigación concluyen que la mayoría de las edificaciones educativas presentan una alta vulnerabilidad sísmica y no cumplen con los requerimientos de uso post-sismo como se exige en la norma sismorresistente; así como también se verificó la deficiencia del módulo 780 Pre frente a un sismo severo cuando este fue sometido a los análisis no-lineales. / Peru is located in a high seismicity zone because it is set above the subduction area between the Nazca and South American tectonic plates, both belonging to the Pacific’s Ring of Fire. Being a developing country, it is of utmost importance to be prepared to help the thousands of victims that may be in the face of a major seismic event. The assessment of the seismic vulnerability of essential buildings —such as schools and hospitals— is necessary for structural reinforcement procedures in this type of infrastructure if needed. In this thesis, it is presented how vulnerable are the public schools of the district of San Juan de Miraflores in the city of Lima to a seismic event. For this, the FEMA P-154 Rapid Visual Screening methodology was used. In addition, the “780 Pre” public school building, a standardized educational building built in the 1990s and whose presence is frequent in that district, was analyzed quantitatively. For this, a static nonlinear and dynamic nonlinear analysis were performed. The results of the investigation show that most of the educational buildings present high seismic vulnerability and do not meet the requirements of post-earthquake use as required by the Peruvian seismic design provisions. Also, the deficiency of the 780 Pre building against a severe earthquake when it was subjected to non-linear analyzes was verified. / Tesis
12

Análisis de errores constructivos y propuesta de reforzamiento con malla de alambre galvanizado en viviendas de albañilería confinada en sectores con alto riesgo sísmico del distrito de Villa El Salvador – Lima / Analysis of constructive errors and proposal of reinforcement with galvanized wire mesh in masonry houses confined to sectors with high seismic risk in the district of Villa El Salvador – Lima

Goñi Paulino, Wilder Brayan, Maquin Damazo, Nehemias Isaias 13 September 2020 (has links)
En la investigación se analiza el estado de las viviendas de albañilería confinada construidas sin asistencia profesional en zonas con alto riesgo sísmico del distrito de Villa El Salvador. Se estudian los errores constructivos mediante la inspección visual de las casas autoconstruidas, las cuales presentan una alta vulnerabilidad frente a un terremoto de gran magnitud, en los sectores I (zona 1) y III (zona 2) del distrito. El error constructivo más frecuente que se ha podido identificar es el uso de ladrillos tubulares (ladrillo pandereta) con un fin estructural. Frente a este problema, la propuesta para mejorar la resistencia a la compresión y fuerzas cortantes de los muros de albañilería de pandereta es reforzarlos con malla de alambre galvanizado recubierta con mortero. Lo que se busca es proporcionar, por lo menos, un área segura dentro de las viviendas para que las familias puedan salvaguardar la vida de sus ocupantes frente a la ocurrencia de movimientos telúricos. En ese sentido, mediante ensayos de laboratorio se verifica que el reforzamiento con malla galvanizada mejora, en gran medida, la resistencia a la compresión y al corte de los muros. Además, su implementación resulta ser más económica frente a otras técnicas de reforzamiento como el refuerzo con mallas electrosoldadas. Esto es importante, porque la población beneficiaria pertenece a los niveles socioeconómicos C y D (bajo nivel socioeconómico). / The research analyzes the state of confined masonry houses built without professional assistance in areas with high seismic risk in the district of Villa El Salvador. Constructive errors are studied by visual inspection of self – constructed houses, which have a high vulnerability in the face of a large earthquake, in sectors I (Zone 1) and III (Zone 2) of the district. The most frequent constructive error that has been identified is the use of tubular bricks (pandereta brick) with a structural purpose. In the face of this problem, the proposal to improve the compression resistance and cutting forces of the pandereta masonry walls is to reinforce them with galvanized wire mesh coated with mortar. What is sought is to provide, at least, a safe area within homes so that families can safeguard the lives of their occupants in the face of the occurrence of telluric movements. In this sense, through laboratory tests it is verified that the reinforcement with galvanized mesh improves, to a large extent the resistance to the compression and the cutting of the walls. In addition, its implementation turns out to be more economical compared to other reinforcement techniques such as reinforcing with electro welded meshes. This is important, because the beneficiary population belongs to the socioeconomic levels C and D (low socioeconomic level). / Tesis
13

Evaluación mixta del sistema de evacuación: interacción del comportamiento humano, basado en Agent Based Modelling, y estructural, con análisis tiempo-historia no lineal, de un edificio educativo de 8 pisos ubicado en San Isidro, Lima, Perú / Mixed evaluation of the evacuation system: interaction of human behavior, based on agent based modelling, and structural, with nonlinear time-history analysis, of an 8-story educational building located in San Isidro, Lima, Peru

Rosales Baltazar, Rooy Alex, Delgado Basurco, Mauricio Fernando 21 October 2021 (has links)
La presente investigación se realizó para evaluar el desempeño estructural y funcional del sistema de evacuación, de un edificio educativo superior durante un sismo severo, en atención a lo cual, se analizó mediante el método basado en Agent Based Modelling y Análisis Tiempo-Historia no Lineal. No obstante, el análisis no se limita solo a edificaciones esenciales; se puede aplicar para edificios importantes y comunes que concentran gran cantidad de personas, ya que el lineamiento que se plantea en esta tesis busca una alternativa más que se debe tener en cuenta en los proyectos de la construcción civil. La información estructural y geotécnica del edificio en estudio, se recopila y se introduce en una base de datos para su análisis. Se realiza un procedimiento similar para la información relacionada de los ocupantes. Usando estas informaciones: a) Se determinará la fragilidad estructural y el colapso localizado, b) se establecerá la interacción de la persona con el colapso focalizado. Para el primer aspecto, se utilizará el historial de tiempo no lineal; para el segundo, el modelado basado en agentes se empleará para recrear la reacción de las personas que enfrentan el micro colapso. Los resultados importantes de estas evaluaciones son: 1) Se ha localizado vigas, columnas y muros de corte colapsadas que afectan la evacuación; 2) Se ha ubicado de cuellos de botella, donde presentan gran concentración de personas durante la evacuación; y 3) se ha cuantificado a las personas afectadas, en términos de individuos atrapadas en el edificio que no pudieron evacuar. / The present investigation was carried out to evaluate the structural and functional performance of the evacuation system of a high-rise higher education building during a severe earthquake, which was analyzed using the Agent Based Modeling and Non-Linear Time-History Analysis method. However, the analysis is not limited only to essential buildings; it can be applied to important and common buildings that concentrate a large number of people, such as: Health establishments, airports, shopping centers, stadiums, condominiums, etc., since the guideline proposed in this thesis seeks one more alternative to be taken into account in civil construction projects. The structural and geotechnical information of the building under study is compiled and entered into a database for analysis. A similar procedure is performed for the related occupant information. Using this information: a) the structural fragility and localized collapse will be determined, b) the interaction of the person with the focused collapse will be established. For the first aspect, nonlinear time history will be used; for the second, agent-based modeling will be used to recreate the reaction of people facing the micro collapse. The important results of these evaluations are: 1) collapsed beams, columns and shear walls have been located, which make evacuation routes inoperable; 2) bottleneck areas have been located, where they present high concentration of people during evacuation; and 3) affected people have been quantified, in terms of individuals trapped in the building who could not evacuate. / Tesis

Page generated in 0.066 seconds