• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Paper-Based Sensors for Contaminant Detection Using Surface Enhanced Raman Spectroscopy

Jain, Ishan 29 June 2015 (has links)
Surface enhanced Raman spectroscopy (SERS) is highly promising analytical technique for trace detection of analytes. It is particularly well suited for environmental analyses due to its high sensitivity, specificity, ease of operation and rapidity. The detection and characterization of environmental contaminants, using SERS is highly related to the uniformity, activity and reproducibility of the SERS substrate. In this thesis, SERS substrates were produced by gold nanoparticle formation on wax patterned chromatography paper. In situ reduction of hydrogen tetrachloroaurate (gold precursor) by trisodium citrate dihydrate (reducing agent) was used to produce gold nanoparticles within a paper matrix. These gold nanoparticle based SERS substrates were analyzed by FE-SEM, UV-Vis and Raman spectroscopy. This work discusses the SERS signal enhancements for Raman active MGITC dye for a series of substrates prepared by in situ reduction of gold salt and pre-produced gold nanoparticles. UV-Vis analysis was performed to understand the effect of different molar ratio (reducing agent to gold precursor) and reaction time on the size and shape of the localized surface plasmon resonance (LSPR) band that dictates the SERS enhancements. It was concluded that lower molar ratio (1:1 and 2:1) of citrate-to gold produced better SERS signal enhancements and broader LSPR band. Therefore, use of lower molar ratio (MR) was recommended for paper-based substrates using in situ-based reduction approach. / Master of Science
2

Untersuchungen zur Quantifizierung der Grundwasserimmission von polyzyklischen aromatischen Kohlenwasserstoffen mithilfe von passiven Probennahmesystemen

Börke, Peter 30 March 2007 (has links)
Kern der Arbeit bildete die Entwicklung einer Fluxmeter-Passivsammlereinheit für hydrophobe organische Substanzen im Grundwasser kontaminierter Standorte sowie deren Testung im Feld. Ferner kamen Keramik-Dosimeter unter identischen Feldbedingungen zum Einsatz. Die Ergebnisse der beiden passiven Sammelsysteme wurden mit herkömmlicher Grundwasserprobennahmetechnik mithilfe von Unterwassermotorpumpen verglichen und bewertet. Grundlage für den Einsatz der Passivsammlereinheit als „mass flux meter“ bildete die Kenntnis über den Volumenstrom im Bohrloch und den reduzierten Volumenstrom in der Passivsammlereinheit und andererseits über die räumliche Verteilung der hydraulischen Durchlässigkeit und der daraus resul¬tierenden heterogenen Geschwindigkeitsverteilung bzw. der Volumenströme über so genannte Kontroll¬ebenen bzw. Teilbilanzräume. Anhand numerischer Modelluntersuchungen konnten der Filterwiderstand der Passivsammlereinheit und die Strömungsverteilung in Modellkontrollebenen und im Feld näherungsweise bestimmt werden. Die Bestimmung des Volumenstromes des untersuchten Standortes wurde zum einen mithilfe von numerischen Modelluntersuchungen an stochastisch generierten quasi-3-dimensionalen Modellen mit hydro¬dynamischen Randbedingungen und kF-Wertverteilungen aus dem Feld und zum anderen mithilfe von Einbohrlochverfahren durchgeführt. Als Einbohrlochverfahren kamen zum einen ein optisches Kolloid-Logging (Grundwasserfluss-Visualisierungssystem) und zum anderen ein modifiziertes Fluidlogging-Verfahren mit Hilfe eines Salztracers zum Einsatz.
3

Measuring understanding and modelling internet traffic

Hohn, Nicolas Unknown Date (has links) (PDF)
This thesis concerns measuring, understanding and modelling Internet traffic. We first study the origins of the statistical properties of Internet traffic, in particular its scaling behaviour, and propose a constructive model of packet traffic with physically motivated parameters. We base our analysis on a large amount of empirical data measured on different networks, and use a so called semi-experimental approach to isolate certain features of traffic we seek to model. These results lead to the choice of a particular Poisson cluster process, known as Bartlett-Lewis point process, for a new packet traffic model. This model has a small number of parameters with simple networking meaning, and is mathematically tractable. It allows us to gain valuable insight on the underlying mechanisms creating the observed statistics. / In practice, Internet traffic measurements are limited by the very large amount of data generated by high bandwidth links. This leads us to also investigate traffic sampling strategies and their respective inversion methods. We argue that the packet sampling mechanism currently implemented in Internet routers is not practical when one wants to infer the statistics of the full traffic from partial measurements. We advocate the use of flow sampling for many purposes. We show that such sampling strategy is much easier to invert and can give reasonable estimates of higher order traffic statistics such as distribution of number of packets per flow and spectral density of the packet arrival process. This inversion technique can also be used to fit the Bartlett-Lewis point process model from sampled traffic. / We complete our understanding of Internet traffic by focusing on the small scale behaviour of packet traffic. To do so, we use data from a fully instrumented Tier-1 router and measure the delays experienced by all the packets crossing it. We present a simple router model capable of simply reproducing the measured packet delays, and propose a scheme to export router performance information based on busy periods statistics. We conclude this thesis by showing how the Bartlett-Lewis point process can model the splitting and merging of packet streams in a router.
4

Silikonstab-Passivsammler für hydrophobe Organika: Aufnahmekinetik, Verteilungskoeffizienten, Modellierung und Freiland-Kalibrierung

Gunold, Roman 14 December 2015 (has links)
Diese Dissertation beschäftigt sich mit der passiven Probenahme von hydrophoben organischen Schadstoffen in Oberflächengewässern: Polyaromatische Kohlenwasserstoffe (PAK), polychlorierte Biphenyle (PCB), polybromierte Biphenylether (PBDE), Organochlorpestizide (u. a. HCH, DDX) und weitere hydrophobe Pestizide. Die Zielstellung dieser Arbeit lag bei der Validierung des Silikonstabs als Alternativmethode im Gewässermonitoring zu konventionellen Probenahmetechniken wie Schöpf- und Wochenmischproben der Wasserphase sowie Schwebstoffanalysen. Die Probenahme mit dem Silikonstab erfolgte durch dessen Exposition im Gewässer für einen Zeitraum zwischen einer Woche und mehreren Monaten. Nach Einholung wurden die im Silikonstab akkumulierten Schadstoffe (Analyten) mittels instrumenteller Analytik quantifiziert. Die Probenaufgabe erfolgte ohne vorherige Lösungsmittelextraktion durch direktes Erhitzen des Silikonstabs, wodurch die Analyten vom Polymer desorbieren (Thermodesorption). Die durch Hitze freigesetzten Analyten wurden direkt auf eine chromatographische Trennsäule gegeben und massenspektroskopisch quantifiziert. Nach Erhalt der Ergebnisse der Silikonstab-Analytik gibt es verschiedene Herangehensweisen für die Berechnung der zeitgemittelten Analytkonzentrationen im Gewässer, die in dieser Arbeit vorgestellt und diskutiert werden. Dazu gehören die Verwendung von experimentellen Daten aus Kalibrierversuchen und Berechnungen auf Grundlage von physikochemischen Eigenschaften der Analyten wie dem Sammler-Wasser-Verteilungskoeffizienten. Im Zuge dieser Arbeit wurde die Aufnahmekinetik des Silikonstabs bei verschiedenen Temperaturen und Fließgeschwindigkeiten mit Hilfe von Kalibrierversuchen untersucht. Die gewonnenen experimentellen Daten wurden für die Entwicklung von Rechenmodellen herangezogen, mit denen das Aufnahmeverhalten vorgesagt werden soll. Es wurden Sammler-Wasser-Verteilungskoeffizienten für den Silikonstab u. a. mit der Kosolvenzmethode bestimmt und als Parameter für die Berechnung von zeitgemittelten Analytkonzentrationen des Gewässers verwendet. Für die Validierung wurde der Silikonstab in zwei Gewässergütemessstationen der Fließgewässer Mulde (Dessau) und Elbe (Magdeburg) in Durchflussbehältern exponiert und die zeitgemittelten Analytkonzentrationen mit verschiedenen Rechenmodellen bestimmt. Die erhaltenen Werte werden mit gleichzeitig entnommenen Wochenmischproben der Wasserphase sowie monatlichen Schwebstoffproben verglichen und die Eignung des Silikonstabs als alternative Probenahmemethode für das Umweltmonitoring von Oberflächengewässern diskutiert.:I ZUSAMMENFASSUNG ...................................................................................................... 2 II INHALTSVERZEICHNIS .................................................................................................. 3 III ABBILDUNGSVERZEICHNIS .......................................................................................... 5 IV TABELLENVERZEICHNIS ................................................................................................ 6 V GLEICHUNGSVERZEICHNIS ............................................................................................ 7 VI ABKÜRZUNGSVERZEICHNIS........................................................................................... 9 0 VIELEN DANK AN … ...................................................................................................... 11 1. EINLEITUNG ................................................................................................................ 12 1.1 Wasser, seine Nutzung und Verschmutzung ............................................................ 12 1.2 Das Wasser und seine Schadstoffe .......................................................................... 15 1.3 Monitoring von Oberflächengewässern .................................................................... 17 1.3.1 Entnahme konventioneller Schöpfproben .............................................................. 17 1.3.2 Entnahme von Mischproben (integrative oder Kompositproben) ........................... 18 1.3.3 Probenahme des Schwebstoffanteils in der Wasserphase .................................... 19 2. PASSIVSAMMLER IN DER WASSERANALYTIK ................................................................ 21 2.1 Theoretische Grundlagen ......................................................................................... 21 2.1.1 Allgemeiner Aufbau von Passivsammlern ............................................................... 23 2.1.2 Die einzelnen Schritte von der Wasser- in die Sammelphase ................................ 25 2.1.3 Adsorptive und absorptive Akkumulation des Analyten in der Sammelphase ........ 26 2.2 Passivsammlersysteme in der Wasseranalytik ......................................................... 28 2.2.1 Absorbierende Passivsammler für hydrophobe Analyten ....................................... 28 2.2.1.1 Semipermeable membrane device (SPMD) .......................................................... 28 2.2.1.2 LDPE-Streifen (LDPE strips) ................................................................................ 29 2.2.1.3 Silikonplatten (silicone sheets) ........................................................................... 30 2.2.1.4 Chemcatcher ...................................................................................................... 31 2.2.1.5 Lösungsmittelfreie Passivsammler (MESCO / Silikonstab) .................................. 32 2.2.2 Absorbierende Passivsammler für polare Analyten ............................................... 35 2.2.2.1 Polar organic integrative Sampler (POCIS) ......................................................... 35 2.2.2.2 Chemcatcher ...................................................................................................... 35 2.3 Auswertung von Passivsammlerdaten ..................................................................... 35 2.3.1 Gleichgewichtssammler ......................................................................................... 36 2.3.2 Laborkalibrierung .................................................................................................. 37 2.3.3 In-situ-Kalibrierung mit Performance Reference Compounds (PRC) ...................... 38 2.3.4 Validierung von Passivsammlern............................................................................ 39 3. LÖSLICHKEIT UND THERMODYNAMISCHES GLEICHGEWICHT ...................................... 41 3.1 Freie Enthalpie und chemisches Potential ................................................................ 41 3.2 Lineare freie Energie-Beziehungen (LFER) für die Abschätzung von KSW ................ 41 3.3 Kosolvenzmodelle für die Modellierung von KSW ...................................................... 43 3.3.1 Log-Linear-Modell von Yalkowsky .......................................................................... 43 3.3.2 Freie Enthalpie-Ansatz (Khossravi-Connors-Modell) .............................................. 44 3.3.3 Jouyban-Acree-Modell ............................................................................................ 44 4. MATERIAL UND METHODEN ......................................................................................... 45 4.1 Präparation der verwendeten Passivsammler .......................................................... 45 4.2 Laborkalibrierung zur Bestimmung von Sammelraten ............................................... 45 4.2.1 Beschreibung der Versuche für die Silikonstab-Kalibrierung .................................. 45 4.3 Experimentelle Bestimmung von Sammler-Wasser-Verteilungskoeffizienten KSW ... 48 4.3.1 Zeitabhängige KSW-Bestimmung in der Wasserphase .......................................... 48 4.3.2 KSW-Bestimmung mit der Kosolvenzmethode ....................................................... 50 4.4 Validierung des Silikonstabs an limnischen Gewässergütemessstationen ............... 52 5. ERGEBNISSE UND DISKUSSION ................................................................................... 55 5.1 Sammelraten RS für den Silikonstab aus Kalibrierversuchen .................................... 55 5.1.1 Temperaturabhängigkeit ....................................................................................... 58 5.1.2 Einfluss der Hydrodynamik auf die Aufnahmekinetik von PAK ................................ 59 5.1.3 Modellierung von Sammelraten .............................................................................. 62 5.1.3.1 Polynomisches Modell nach Vrana [137] ............................................................. 62 5.1.3.2 Diffusionsmodell nach Booij [71] ......................................................................... 64 5.1.3.3 Diffusionsmodell nach Rusina [85] ...................................................................... 66 5.1.4 Wahl der geeigneten In-situ-Kalibrierung am Beispiel eines Kalibrierversuchs ..... 67 5.1.4.1 Berechnung von In-situ-Sammelraten mit RS-Modellen ...................................... 68 5.1.4.2 Berechnung von In-situ-Sammelraten über Eliminierung von PRCs .................... 69 5.1.4.3 Vergleich Modelle und PRCs mit experimentellen Sammelraten .......................... 70 5.2 Experimentelle Bestimmung des Sammler-Wasser-Verteilungskoeffizienten KSW ... 73 5.2.1 Zeitabhängige KSW-Bestimmung in der Wasserphase .......................................... 73 5.2.2 Zusammenfassung KSW(t)-Versuche in der Wasserphase .................................... 81 5.2.3 KSW-Bestimmung mit der Kosolvenzmethode ....................................................... 81 5.2.3.1 Kosolvenzmodelle ............................................................................................... 83 5.2.4 Zusammenfassung ................................................................................................ 90 5.3 Empirische Modelle zur Abschätzung von KSW-Werten ............................................ 92 5.3.1 Lineare Korrelation des KSW mit physikochemischen und Molekülparametern ...... 92 5.3.2 Berechnung mit Mehrparameter-Regression (LSER) .............................................. 95 5.3.3 Zusammenfassung Abschätzung von KSW-Werten für den Silikonstab ................. 97 5.4 Freilandvalidierung des Silikonstab-Passivsammlers ................................................ 97 5.4.1 Ausbringung an Gewässergütemessstationen....................................................... 97 5.4.1.1 Validierung des Silikonstabs mit Wasserproben ............................................... 100 5.4.1.2 Validierung des Silikonstabs mit Sedimentproben ............................................ 102 5.4.2 Validierung des Silikonstabs bei Laborvergleichsstudien ..................................... 105 6. ERGEBNISSE UND AUSBLICK ..................................................................................... 105 VII LITERATURVERZEICHNIS ......................................................................................... 107 VIII ANHANG ................................................................................................................. 116

Page generated in 0.1132 seconds