• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude des propriétés des scintillateurs organiques liquides

Michel, Luc 21 September 1995 (has links)
Fichier attaché.
2

Etude des propriétés des scintillateurs organiques liquides

Michel, Luc 21 September 1995 (has links)
Fichier attaché.
3

Caractérisation de scintillateurs liquides à base d'eau pour l'utilisation en dosimétrie

Bernier-Marceau, Daphnée 25 January 2024 (has links)
Thèse ou mémoire avec insertion d'articles / La radiothérapie est une approche thérapeutique permettant de délivrer une dose de radiation à une région tumorale. Cependant, cette méthode de traitement peut également affecter les tissus sains environnants, provoquant des effets secondaires indésirables chez les patients. Pour minimiser ces effets secondaires, il est nécessaire de valider les doses de radiation des tissus sains tout en assurant une couverture optimale de la dose à la tumeur. Les dosimètres utilisés pour effectuer ces validations ont en majorité des propriétés qui ne sont pas similaires à celles du milieu de référence en radiothérapie, l'eau. Ainsi, la dose mesurée par le scintillateur doit être ajustée à celle qui serait mesurée dans l'eau sans la présence du dosimètre, ce qui implique que des facteurs de correction doivent être calculés et utilisés pour la validation de la dose. Quoique minimes, les erreurs engendrées par ces coefficients ne sont pas nulles et pourraient avoir un impact sur les incertitudes reliées à la mesure de dose. Dans ce contexte, le besoin d'un dosimètre équivalent à l'eau en milieu clinique est grandissant. En revanche, la plupart des scintillateurs liquides et plastiques équivalents à l'eau contiennent des solvants qui peuvent être néfastes pour la santé des personnes qui doivent les utiliser. Dès lors, en milieu clinique, des mesures de sécurité additionnelles doivent être prises afin de maintenir un environnement sans danger pour le personnel et les patients. Un scintillateur composé en majorité d'eau aurait alors l'avantage d'une meilleure équivalence à l'eau tout en minimisant les effets néfastes sur la santé des utilisateurs et leur environnement. C'est dans ce contexte que le mémoire présenté vise à caractériser de nouveaux types de scintillateurs à base d'eau afin d'explorer leur potentiel et leurs performances pour la mesure de la dose en radiothérapie. La caractérisation de scintillateurs liquides à base d'eau s'avère être l'objectif général présenté dans ce mémoire. Quatre scintillateurs ayant respectivement des concentrations en eau de 0%, 40%, 60% et 80% ont été étudiés. La caractérisation des propriétés physiques de ces scintillateurs a permis d'explorer trois aspects : la dépendance de l'efficacité de scintillation selon la concentration d'eau, la comparaison de l'efficacité de scintillation avec un scintillateur de référence ainsi que l'analyse spectrale des scintillateurs. La caractérisation des propriétés dosimétriques des scintillateurs a permis d'analyser la linéarité de la réponse selon la dose, la dépendance du signal au débit de dose ainsi que la variation de la réponse selon le type et la qualité de faisceau. En troisième lieu, l'aspect volumétrique du scintillateur liquide à base d'eau a été étudié par l'évaluation des distributions de dose à haute énergie. L'évaluation de l'efficacité de scintillation a permis de quantifier la diminution du signal émis avec l'augmentation de la concentration d'eau pour une même dose déposée au scintillateur. Une efficacité de scintillation relative moyenne de 25% a été obtenue pour le scintillateur ayant une concentration en eau de 80% comparativement au scintillateur n'ayant pas d'eau dans son mélange. En second lieu, il a été possible d'observer que les scintillateurs liquides ayant majoritairement de l'eau comme solvant ont une réponse linéairement proportionnelle à la dose délivrée. Leur réponse ne varie pas selon le débit de dose. Le scintillateur ayant une concentration en eau de 80% possède la plus faible dépendance selon l'énergie et le type de faisceau, avec une dépendance d'au maximum 4% pour toute la gamme d'énergies en photons, du kilo- au méga-voltage, et d'au maximum 5% pour la gamme d'énergie en électrons explorée. Finalement, il a été possible de valider que les scintillateurs liquides à base d'eau offrent des résultats similaires aux scintillateurs standards lors de mesures de distributions de dose en deux dimensions. Des différences négligeables sont observées entre le scintillateur ayant une concentration en eau de 80% et le scintillateur de référence, le Ultima Gold. / Radiotherapy is a therapeutic approach that involves delivering a dose of radiation to a tumor region. However, this treatment method can also affect surrounding healthy tissues, causing undesirable side effects in patients. To minimize these side effects, it is necessary to validate the radiation doses in healthy tissues while ensuring optimal dose coverage for the tumor. The dosimeters used to perform these validations mostly have properties that are not similar to those of the reference medium in radiotherapy, water. Thus, the dose measured by the scintillator must be adjusted to the one deposited in water without the presence of the dosimeter. This requires correction factors to be calculated and used for dose validation. Although these errors are minimal, they are not negligeable and could have an impact on the uncertainties related to dose measurement. In this context, there is a growing need for a water-equivalent dosimeter in a clinical environment. However, most of the water-equivalent liquid and plastic scintillators contain solvants that can be harmful to the health of people who use them. Therefore, additional safety measures must be taken in a clinical setting to maintain a safe environment for staff and patients. A scintillator composed mostly of water would have the advantage of better water equivalence while minimizing harmful effects on the health of users and their environment. It is in this context that this presented work aims to characterize these new types of water-based scintillators to explore their potential and performance for dose measurement in radiotherapy. The general objective presented in this thesis is the characterization of water-based liquid scintillators. Four scintillators with water concentrations of 0%, 40%, 60%, and 80% were studied. The characterization of the physical properties of these scintillators allowed exploration of three aspects : the dependence of scintillation efficiency on water concentration, comparison of scintillation efficiency with a reference scintillator, and spectral analysis of the scintillators. The characterization of the dosimetric properties of the scintillators allowed analysis of the linearity of the response to dose, the dependence of the signal on dose rate, and the variation in response according to beam type and quality. Finally, the volumetric aspect of the water-based liquid scintillator was studied by evaluating high-energy dose distributions. The evaluation of the scintillation efficiency allowed to quantify the decrease in emitted signal with increasing water concentration for the same deposited dose in the scintillator. An average relative scintillation efficiency of 25% was obtained for the scintillator with an 80% water concentration compared to the scintillator without water in its mixture. Secondly, it was possible to observe that liquid scintillators predominantly composed of water as a solvent exhibit a linearly proportional response to the delivered dose. Their response does not vary with dose rate. The scintillator with an 80% water concentration has the lowest energy and beam type dependence, with a maximum dependence of 4% across the entire range of photon energies from kilo- to mega-volts, and a maximum dependence of 5% within the explored electron energy range. Finally, it was possible to validate that water-based liquid scintillators offer similar results to standard scintillators in two-dimensional dose distribution measurements. Negligible differences are observed between the scintillator with an 80% water concentration and the reference scintillator, Ultima Gold.
4

Étude des mécanismes des réactions induites par les noyaux à halo de neutrons 11Be (49,2 MeV/nucléon) et 6He (41,5 MeV/nucléon) sur le plomb en fonction de l'inélasticité des collisions

Patois, Y. 31 August 2001 (has links) (PDF)
Dans ce travail, nous avons montré comment la structure en halo de neutron d'un noyau se manifestait sur les mécanismes de réaction. Notre étude expérimentale a été appliquée à un noyau doté d'un seul neutron dans le halo (11Be) et à un noyau doté de deux neutrons dans son halo (6He) dans leurs interactions avec un noyau-cible de plomb. Le dispositif expérimental permettait une mesure simultanée des impulsions du noyau-cœur et des neutrons du halo, ainsi que de l'état d'excitation du noyau-cible. La mesure des caractéristiques cinématiques des neutrons du halo était effectuée par le nouveau détecteur TOURNESOL, un détecteur par temps de vol à scintillateur liquide de large volume. Les caractéristiques de ce détecteur sont décrites en détail dans ce document. Pour les deux faisceaux, nous avons obtenu des mesures sélectives de largeurs en impulsion, en distinguant les réactions de break-up, stripping et cassure de cœur, ainsi que différents domaines d'excitation du noyau-cible. En faisceau de 11Be les largeurs d'impulsion du noyau-cœur et du neutron de halo sont cohérentes pour les réactions de break-up, et le noyau-cible n'est pas excité. Les valeurs obtenues sont de 10 à 15% supérieures aux valeurs équivalents obtenues avec un noyau-cœur au voisinage de zéro degré. Des largeurs de distributions d'impulsion des neutrons produits lors de la cassure du cœur ont été comparées à celles en faisceau de 10Be. En faisceau de 6He, nous avons étudié les corrélations entre l'impulsion des neutrons et celle du cœur, pour constater qu'en réaction de break-up la dissociation s'effectue en une étape, et en une ou deux étapes en réaction de stripping. Dans ce dernier cas, la cassure en une étape est liée à la structure " di-neutrons " et celle en deux étapes à la structure " cigare " de l'état fondamental du noyau 6He.
5

Production de plasmons et degré d’ionisation pour des reculs nucléaires dans les détecteurs de matière sombre au silicium de SuperCDMS

Michaud, Émile 08 1900 (has links)
SuperCDMS (Super Cryogenic Dark Matter Search) est une expérience de détection directe de la matière sombre qui utilise des détecteurs cryogéniques au silicium et au germanium capables de mesurer des dépôts d'énergie aussi petits que quelques eV. L'un des défis les plus importants de la recherche de la matière sombre est de réussir à bloquer les nombreux bruits de fond. Une de ces sources de bruit de fond est la production de plasmons par la diffusion Compton, un phénomène ne déposant généralement qu'une dizaine d’eV et affectant surtout les détecteurs à semi-conducteurs. Dans cet ouvrage, nous allons estimer le taux de production de ces plasmons et démontrer qu'il est primordial de tenir compte de ce bruit de fond avant de pouvoir affirmer avoir trouvé la matière sombre. Un autre enjeu majeur de SuperCDMS est l'étalonnage de ses détecteurs à très faible énergie. En effet, la matière sombre est supposée interagir avec le noyau des atomes. Toutefois, il n'existe présentement aucune donnée sur le degré d'ionisation pour des reculs nucléaires de moins de 0,7 keVnr dans le silicium, où keVnr représente l'énergie déposée en keV lors d'une collision nucléaire (nr). Dans la deuxième partie de cet ouvrage, nous allons montrer comment l'expérience IMPACT (Ionization Yield Measurement with Phonons At Cryogenic Temperature), une sous-expérience de SuperCDMS composée de membres de SuperCDMS, compte mesurer ce degré d'ionisation pour des reculs nucléaires entre 0,1 et 4 keVnr dans le silicium. Connaître ce degré d'ionisation est d'une grande importance pour SuperCDMS car il permet de reconstruire l'énergie déposée par une particule de matière sombre lorsqu'elle effectue une collision nucléaire dans ses détecteurs de matière sombre. / SuperCDMS (Super Cryogenic Dark Matter Search) is an experiment for the direct detection of dark matter that uses cryogenic silicon and germanium detectors which can measure energy deposition as low as a few eV. One of the biggest challenges in the search for dark matter is to block the various background events. One of those background source is the excitation of plasmons by Compton scattering, a phenomenon that generally deposits about ten eV and which affects mainly semiconductor detectors. In this work, we will estimate the production rate of plasmons and argue that we must understand this background in order to claim evidence of dark matter. One of SuperCDMS's other challenges is the calibration of its detectors at very low energy. Indeed, dark matter is known to interact with the atom's nucleus, but unfortunately, there is no data at the moment about the ionization yield of nuclear recoils below 0,7 keVnr in silicon, where keVnr is the energy deposited in keV in a nuclear recoil (nr). In the second part of this work, we will show how the IMPACT experiment (Ionization yield Measurement with Phonons At Cryogenic Temperature), a sub-experiment of SuperCDMS composed of members of SuperCDMS, aims to measure the ionization yield for nuclear recoils between 0,1 and 4 keVnr in silicon. It is important for SuperCDMS to know this ionization yield to reconstruct the energy deposited in their detectors by a nuclear recoil from a dark matter particle.

Page generated in 0.1054 seconds