• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Nervus medianus påverkan av olika hudtemperaturer. : En jämförelse av hur conduction velocity och peaklatenstiden påverkas av olika hudtemperaturer, mätt med ENeG, SCV. / How the median nerve is affected by different skin temperatures. : A comparison of how the conduction velocity and peak latency time is affected by different skin temperatures, measured by ENeG, SCV.

Neu, Elin January 2020 (has links)
Introduktion: Vid perifera nervundersökningar med elektroneurografi spelar temperaturen i vävnaden som undersöks stor roll. Kall vävnad leder till försämrad funktion i nervernas jonkanaler, vilket leder till att aktionspotentialer utlöses långsammare och nervledningshastigheten minskar vilket därmed kan ge falskt patologiska undersökningsresultat. För att minska den risken mäts och korrigeras alltid hudtemperaturen. Vid registrering från övre extremiteter mäts hudtemperaturen standardmässigt på handryggen. Trots att stimulering sker från handflatan och från fingrar så mäts inte temperaturen där. Syftet med studien är därför att undersöka om kalla fingrar på en i övrigt varm hand påverkar conduction velocity och peaklatenstiden, jämfört med när hand och fingrar har samma varma temperatur. Metod: 30 unga, friska personer deltog i studien. Ortodrom elektroneurografiundersökning utfördes på nervus medianus sensoriska del. Handryggstemperaturen var konstant 32° Celsius (C) och fingertoppstemperaturerna var 32° C, 27° C respektive 22° C. Vid varje fingertoppstemperatur registrerades conduction velocity och peaklatenstiden vid stimuleringar från handflatan, fingerbasen och fingertoppen på digitorum III. Resultat: En statistiskt signifikant skillnad fanns i både nervledningshastigheten och peaklatenstiden vid registrering från fingerbasen vid fingertoppstemperaturen 32° C jämfört med såväl 27° C som 22° C. Slutsats: Kalla fingrar på en varm hand ger en statistiskt signifikant påverkan på både nervledningshastigheten och peaklatenstiden. / Background: In peripheral nerve examinations with electroneurography, temperatures in the tissue that is being examined is important. Cold tissue leads to impaired function of the ion channels of the nerves, which causes action potentials to be triggered more slowly and the nerve conduction velocity to decrease, which can cause false pathological examination results. To reduce this risk, the skin temperature is always measured and corrected. When registering from the upper extremities, the skin temperature is measured by default on the back of the hand. Despite stimulating in the palm and on the fingers, the temperature is not measured there. The purpose of the study is to investigate whether cold fingers on a warm hand affects the conduction velocity and peak latency time, compared with the hand and the fingers having the same warm temperature. Methods: 30 young, healthy persons participated in the study. An orthodrome electroneurography examination was performed on the sensory part of the median nerve. The backhand temperature was constant 32° Celsius (C) and the fingertip temperatures were 32 ° C, 27 ° C and 22 ° C. Results: A statistically significant difference was found in both nerve conduction velocity and peak latency time when registering from the finger base with fingertip temperature 32 ° C compared with both 27 ° C and 22 ° C Conclusions: Cold fingers on a warm hand give a statistically significant effect on both the nerve conduction velocity and the peak latency time.

Page generated in 0.1286 seconds