• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 12
  • 12
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Vergleich von konstanter und periodischer Trenngrenze bei der Thrombozytapherese mit dem Blutzellseparator Fresenius AS 104

Balke, Bettina 28 October 2002 (has links)
Vergleich zweier Thrombozytaphereseprotokolle des kontinuierlich arbeitenden Zellseparators FRESENIUS AS 104 mit dem Ziel einer regelmäßigen Senkung der Leukozytenkontamination (LK) in Thrombozytapheresekonzentraten unter die kritische Grenze für eine Alloimmunisierung von 1 x 106 Leukozyten pro Transfusionseinheit ("critical immunological load of leukocytes" (cill)). Die Bestimmung der Leukozytenzahl in diesem niedrigen Konzentrationsbereich stellt ein bekanntes Problem dar, weshalb drei Methoden dazu miteinander verglichen wurden. Bei je 50 Thrombozytapheresen von gesunden Spendern wurde das Standardprogramm mit konstanter Trenngrenze bzw. die Programm-Modifikation mit periodischer Trenngrenzenposition eingesetzt. Der Vergleich der beiden Trenngrenzeneinstellungen erfolgte auf der Basis der ermittelten LK in den Thrombozytapheresekonzentraten sowie den errechneten Qualitätsparametern Plättchenausbeute und Separationseffizienz. Zur Bestimmung der LK wurden neben der mikroskopischen Auszählung der Zellen mit Hilfe der modifizierten Nageotte-Kammer zum einen ein neuartiger Blutbildautomat (Abbott CD 3500), zum anderen durchflußzytometrische Methode (FACS) verwendet. Die Effektivitätsparameter beider Thrombozytaphereseverfahren wichen signifikant voneinander ab: Der Thrombozyten-Ertrag ist bei Anwendung der konstanten Trenngrenze war im Mittel mit 3,6 x 1011/TE signifikant höher als bei Anwendung der periodischen Trenngrenze mit 3,3 x 1011/TE (t-Test:p = 0,017). Dementsprechend sind bei vergleichbaren Mittelwerten für Separationsdauer (63min vs. 64min) und Separationsvolumen (3588 ml vs. 3737 ml) sowohl die Separationsleistung (5,9 x 109/min vs. 5,2 x 109/min; t-Test: p = 0,018), als auch die Separationseffizienz (48,0% vs. 43,3%; t-Test: p = 0,005) signifikant niedriger bei der Anwendung der periodischen Trenngrenzenposition. Die Leukozytenkontamination ist signifikant niedriger bei Anwendung der periodischen Trenngrenze: Je nach angewandter Methode liegt die mittlere Leukozyten-Kontamination bei Anwendung der konstanten Trenngrenze bei 4,9 x 106/TE, bei Anwendung der periodischen Trenngrenze bei 2,1 bzw. 1,2 x 106/TE (U-Test: p < 0,0001). Bei der Bestimmung mittels FACS lag die Leukozytenkontamination bei 46 von 50 Thrombozytapheresen mit periodischer Trenngrenze unter dem angestrebten Wert von 1 x 106/TE (vs. konstante Trenngrenze: 9 / 50) . Beim Vergleich zwischen Nageotte-Kammer-Zählung als Goldstandard und Blutbildautomat zeigt der Blutbildautomat Abbott CD 3500 bei Leukozyten-Konzentrationen unter 50 bis 80 pro Mikroliter eine unzureichende Genauigkeit (r = 0,546). Zwischen Nageotte-Kammer-Zählung und FACS-Methode findet sich hingegen eine gute Korrelation (r = 0,930). Die Modifikation des Thrombozytenseparationsverfahrens mit periodischer Verschiebung der Trenngrenze bewirkt eine signifikante Senkung der Leukozytenkontamination. Der Thrombozytenertrag und die Separationseffizienz werden um etwa 10% gegenüber dem Standardverfahren mit konstanter Trenngrenze gesenkt. Dieser Thrombozytenverlust ist jedoch bedeutungslos, da die zum Erreichen des gesetzlich vorgeschriebenen cill-Wertes notwendige Filterung des Standard-Thrombozytapheresekonzentrats ebenfalls zu einem Thrombozytenverlust führt, der in derselben Größenordnung liegt. / Comparison of two different separation protocols for plateletpheresis with the Fresenius Blood Cell Separator AS104. Aim was to achieve a low white blood cell (WBC) contamination of the resulting platelet concentrate below the critical immunological load of leukocytes responsible for alloimmunisation. Furthermore comparison of three different methods to determine the exact count of WBC in this low range of WBC concentration. 50 healthy donors each underwent platelet apheresis with the Fresenius Blood Cell Separator AS104 using the periodically alternating interface position (PAIP) or a standard interface position (SIP). To evaluate the influence, WBC contamination of the platelet concentrate and separation efficiency (SE) were investigated. WBC were counted either microscopically (modified Nagotte chamber) or dermined on a whole blood counter Abbott CD 3500 or on a FACScan flowcytometer. SE with PAIP is lower than with SIP ( 43.3% vs. 48%; t-test: p=0.005). WBC contamination with PAIP is lower than with SIP: depending on the method of counting 2.1 resp. 1.2 x 106/TE for PAIP vs. 4.9 x 106/TE for SIP (u-test: p < 0.0001). Correlation between counting the WBC by the modified Nagotte chamber as a ´gold standard´ methode and the Abbott CD 3500 was poor (r = 0.546), whereas counting by modified Nagotte chamber and by FACScan showed a good correlation (r = 0.93). Modification of the separation protocol for platelet apheresis with the Fresenius Blood Cell Separator AS104 by PAIP results in a lower WBC contamination of platelet concentrates. The lower SE and total amount of platelets in the concentrates with the PAIP method compared to SIP make no difference in the end because the concentrates produced with SIP have additionally to be filtered in order to achieve a WBC conatmination below the cill and undergo thereby a reduction of platelets in about the same range.
12

Flotace rozpuštěným vzduchem – od poloprovozního modelu po plnou realizaci / Dissolved Air Flotation – From Pilot Plant to Full Scale Implementation

Dobiáš, Pavel January 2018 (has links)
The thesis deals with the use of dissolved air flotation (DAF) in water treatment technology in the Czech Republic. It summarizes the knowledge gained at pilot plant studies as well as the experience with full-scale flotation units which have been built in potable water treatment plants in the Czech Republic in years 2006-2018. This thesis provides a broad background of experimental studies of a modern separation process, which does have great advantages in the removal of natural organic matter and microorganisms from water in the drinking water treatment industry. In this thesis, there are presented some examples of the excellent efficiency of the microorganisms removal, both under the experimental conditions as well as water treatment plants, which were improved by DAF units installation in full scale. In addition to the high separation efficiency, it is shown, how DAF units could influence the subsequent separation steps as for example filtration through the granular media. The negative influence of the pre-ozonization on the DAF separation efficiency in Hradec Králové WTP is demonstrated too. The results of the pilot experiments support the idea, that the key condition for high removal efficiency is the optimal coagulation process chemistry. Design of pilot experiments was based on the factorial planning theory and some results are discussed in this thesis. The very big portion of the pilot experiments was made for estimating of the full-scale DAF design parameters before the water treatment plants reconstruction phase

Page generated in 0.0933 seconds