111 |
Přepočet a variantní návrh ocelové střešní konstrukce zimního stadiónu v Jihlavě / Static verification and variant design of roof structure of winter sport stadium in Jihlava cityBulíček, Radek January 2014 (has links)
The aim of the thesis is the assessment of steel structure roofing winter stadium in Jihlava city and design of the variant solution of load bearing steel structure of the roof. The ground plan dimensions are 60 x 84 m The current structure is composite of truss main girders with parabolic lower chords, and purlins . Axial distances of main girders are 12 m and are supported on concrete columns. The alternative proposed solution uses arched truss main girders and truss purlins. They are supported on existing concrete columns. All load bearing members of existing and new design structure – main girders, purlins, roof bracing - have been evaluated according to actual normative rules. It is evident that the static assessment of the existing structure is satisfied from viewpoint of ultimate and serviceability limit states. The static assessment of the new structure is satisfied from the viewpoint of both limit states.
|
112 |
Nadzemní parkovací dům / Overground Parking HousePevner, Jan January 2014 (has links)
The work focuses on the design and assessment of selected structural elements of one overground floor monolithic concrete structures and staircases. All calculations are done in accordance with Eurocode 2.
|
113 |
Porovnání návrhů monolitické konstrukce bez a se zohledněním postupu výstavby. / Comparision of design of cast-in-place structure with / without consideration of process constructionVlach, Jakub January 2015 (has links)
The aim of this thesis is to propose and evaluate static three-storey reinforced concrete structure. For static analysis supporting structure was used computer program based on FEM SCIA - Engineer 2013 - student version. In computing program have been two independent computational models and in 2D and 3D space. The results were compared and evaluated with each other. On the basis of the report is drafted drawings consisting of reinforcement drawing and drawing shape.
|
114 |
Lávka pro pěší přes řeku Labe / Pedestrian bridge across the river LabeLibiger, Martin January 2015 (has links)
The thesis deals with a design of the river Labe bridging in the city Hradec Kralove. In order to make option for cyclists and pedistrians to cross between shores. There were made three design variants. For detailed solution curved twin-arm arched structure was chosen. The aim of the thesis was design and assessment of Bering strucutre of the footbridge according ultimate limit states and serviceability limit state given by valid Eurocodes.
|
115 |
Obchodní a administrativní centrum / Business and office centreNovotný, Petr January 2015 (has links)
The aim of this master´s thesis was design and analysis of a steel supporting structure of a building for business and administration purposes in Ostrava. It includes an assessment of the main load-bearing construction elements and the selected connections. The thesis also contains the design documentation of the building and compares two different variants of the steel construction design.
|
116 |
Lávka pro pěší / FootbridgeGrussmann, Jan January 2015 (has links)
Master´s thesis deals with design and complex static assessment of timber roofed footbridge structural system. The calculation part is divided into three main chapters, that are dedicated to determine load impacts on structure, to particular structural and roof members assessment and also to design details of connections. The lower part of structure is formed by flat arched main beams of glued laminated timber, floor beams, stringers and under-deck bracing. The upper part of footbridge is formed by structure of gabled roof and additional bracings. Transversal frames of footbridge copy the shape of arch and they are arranged orthogonally to its axis. They form a radial fan with commom centre in the longitudinal direction. The static scheme of structure is thought as a statically undefinite system thanks to the bedrock surrounding the footbridge.
|
117 |
Napěťová, deformační a bezpečnostní analýza statoru generátoru zatíženého nehomogenní teplotou / Stress, deformation and safety analysis of the generator stator loaded by nonhomogeneous temperatureMajdič, Petr January 2015 (has links)
This thesis deals with stress, strain and reliability analysis of synchronous generator stator including an inhomogeneous temperature field. Using the finite element method, stress and strain are calculated, and from these values safety against yield strength is determined, which is followed by the life calculation of the most stressed weld joint and the determination of its possible damage during the period required by the customer.
|
118 |
Montovaná skeletová konstrukce nákupního centra / Precast concrete frame building of shopping centreBřeňová, Marie January 2016 (has links)
The diploma thesis is focused on the design and review of selected load-bearing elements of the precast hall. Girder is dimensioned in two variants: reinforced and prestressed concrete. Design and assessment of prestressed girder was carried out using the simplified method and the IDEA statica. Column and footing was also dimensioned. All calculations are done in accordance with Eurocode 2.
|
119 |
Návrh ŽB nosné konstrukce víceúčelového objektu / RC load-bearing structure design of multipurpose-buildingBody, Roman January 2016 (has links)
The aim of diploma thesis is design and appraise the structure of the spatial reinforced concrete object founded on foundation slab. The structure is without the cladding. To the calculation of internal forces is used computing software Scia Engineer 15. Roof slab, rung, beam and column are designed. Designed life of the structure is 50 years.
|
120 |
Návrh mostu přes řeku / Design of the bridge over the riverBýčková, Klára January 2016 (has links)
The aim is to propose solutions to the new bridge construction due to its unsatisfactory compared to the existing bridge reconstruction project . There are three studies bridging and selected variant trapezoidal plate further processed static opinion. The design was judged by the ultimate limit states and usability. Partial assessments were made for the anchoring system, anchorage area , unravels notched bars and store design to support .
|
Page generated in 0.0449 seconds