81

Adsorption : filtration hybrid system in wastewater treatment and reuse.

Chaudhary, Durgananda Singh January 2003 (has links)
University of Technology, Sydney. / Wastewater contains a matrix of organic and inorganic substances both in dissolved form and in suspension. Most of the biodegradable substances are removed in primary and secondary treatment processes. However, the conventional wastewater treatment processes cannot remove a number of synthetic and refractive organic substances. These substances can cause tremendous problem in the sewage treatment processes and in the water body where the effluent from the sewage plant is discharged. These substances produce odour, colour, and require a large quantity of disinfectant dose before the wastewater can be discharged into a water body. They can also significantly deplete the dissolved oxygen level of the water receiving body thus putting all the aquatic life in danger. The effluent from the sewage treatment plant therefore, needs to be passed through further treatment process, which is called advanced sewage treatment process. The advanced treatment processes consist of many treatment options. Depending upon the characteristics of the sewage and the level of treatment required, one has to select an appropriate treatment technology. Physico-chemical processes such as coagulation-flocculation and filtration, adsorption, and membrane application are some of the most viable treatment processes that can remove the organic substances to the desirable level. In this study, adsorption, biosorption or biofiltration, and adsorption-membrane hybrid systems were investigated for the removal of organics (in terms of total organic carbon (TOC)) from a low strength synthetic wastewater and a biologically treated secondary effluent from a sewage treatment plant, Sydney. Adsorption experiments were conducted on low strength synthetic wastewater and the biologically treated sewage effluent using granular activated carbon (GAC) and powder activated carbon (PAC). The synthetic wastewater was prepared using three organic substances (glucose, peptone and yeast extract) and seven inorganic chemicals (MnS04, CaCI2, NaHC03, NaCl, MgS04·7H20, KH2P04 , and NH2·NH2·H2S04). The biologically treated sewage effluent was collected from the St. Marys sewage treatment plant, Sydney. Detailed experimental studies on adsorption equilibrium, batch kinetics and fixed bed were carried out, and the experimental results were predicted using suitable mathematical models. The adsorption equilibrium was analysed with different initial organic concentration of the synthetic wastewater. The experimental results were then predicted using association theory (AT), characterization theory (CT), and the Freundlich isotherm. The experimental results showed unfavourable type of isotherm curve, and hence, the normal favourable isotherm equations such as Langmuir, Freundlich or Sipps isotherms were not very successful in describing the adsorption equilibrium results. The AT and the CT were better in predicting the adsorption equilibrium results than the commonly used Freundlich isotherm. In this process, the adsorption equilibrium (isotherm) parameters were determined using a multi variable, non-linear regression, Nelder-Mead method by optimising an object function defined as the mean percent deviation between experimental and calculated equilibrium adsorption amounts. The isotherm parameters were found to be dependent on the initial organic concentration. Hence, it is important to estimate the isotherm parameters covering a wide range of organIc concentration. Further, the adsorption equilibrium studies of the individual organic compounds indicated that the overall effects of the inorganic substances were unfavourable for the adsorption of organics in the wastewater. The organics of the synthetic wastewater were found to undergo biodegradation after 8 hours. Thus, the effect of the background substances in the wastewater, and the biodegradation effect are another important aspects that need to be considered while evaluating the effectiveness of the adsorption process for organic removal from the wastewater. It is equally important to study the adsorption behaviour with time (i.e. adsorption kinetics). Adsorption kinetics of the organics in the wastewater was determined using linear driving force approximation (LDFA) model. Basically, the LDFA is a simplified expression of intraparticle diffusion of adsorbate into adsorbent particles. In this model, it is assumed that the uptake rate of adsorbate by an adsorbent particle is linearly proportional to the driving force developed due to the difference between the surface concentration and the average adsorbed phase concentration of the adsorbate. The main reason for using the LDFA method was the use of index (or lumped) parameter, total organic carbon (TOC), to express the total organic contents of the wastewater. The film mass transfer coefficient (kf) was found to be dependent on the experimental conditions such as mixing intensity, the adsorbent dose and the initial organic concentrations. The film mass transfer coefficient (kf) to the adsorbent increased when the mixing intensity and the adsorbent dose were increased. However, the kf value decreased with the increase in the initial organic concentration of the solution. The adsorption isotherm parameters obtained from the association theory (AT) and the characterization theory (CT), were utilized to fit the experimental results using LDFA model. The isotherm parameters obtained from both the theories were found equally effective in predicting the experimental results. The overall effect of the dissolved inorganic compounds in the synthetic wastewater solution was observed to enhance the mass transfer rate to the GAC particle. The average value of the overall mass transfer rate was in the order of 10-6 mls. The application of adsorption system in practice is usually carried out in the fixed bed adsorption mode. The adsorbent (usually GAC) is packed in a column and the target pollutants are passed through either end to be adsorbed by the adsorbent. In this study, the fixed bed adsorption study was carried out in acrylic columns in the laboratory. The GAC bed depth, organic concentration of the feed solution, and the filtration velocity through the GAC bed were varied to evaluate the effectiveness of the fixed bed adsorption system. The experiments were carried out with both the biologically treated sewage effluent and the synthetic wastewater. The experimental results were predicted using the dynamic adsorption model. The film mass transfer coefficient (kf) was obtained by fitting the fixed bed experimental data. The kf increased when filtration rate was increased, but it decreased with the increase in the organic concentration of the feed solution. As expected, the value of kf remained constant with the increase in GAC bed depth. The effect of axial dispersion coefficient was negligible, as the GAC bed depth and the size of the GAC particles used in this study were shallow and small respectively. The average value of the overall mass transfer rate in the fixed bed study was also in the order of 10-6 mls but slightly less than that obtained in batch kinetics study. The fixed bed system with attached microorganisms on the surface of the adsorbent (fixed bed medium) is referred to as a biofilter, where the organics are adsorbed (biosorption) and biodegraded by the microorganisms. The fixed bed adsorption experimentations were conducted for a longer duration to investigate the biological activity on the granular activated carbon (GAC). The experimental results showed the growth of microorganisms on the surface of GAC particles. In other words, the adsorption system turned into biosorption or biofiltration system after few weeks of operation. The adsorption capacity of the GAC particles slowly exhausted with the growth of microorganisms with time. The overall organic removal efficiency of the system was however, not impaired by the growth of microorganisms. The organics were removed by the processes of biosorption and subsequent biodegradation. The biomass growth rate was found to fluctuate with time in pattern. Despite the fluctuation in the biomass, the TOC removal efficiency of the biofiltration system was consistent at 55 % for 77 days of continuous operation. Moreover, the daily backwashing provided at 30 % bed expansion to avoid filter clogging did not have adverse effect on the TOC removal efficiency of the biofilter. The organic removal efficiency of the biofilter changed when the filtration rate was altered from that in which the biofilter was acclimatized~ however the organic removal pattern remained consistent with time. This result suggests that the biofilter should be operated in the same filtration velocity at which it is acclimatized to attain maximum efficiency of the filter. A practical mathematical model was developed incorporating both adsorption and biodegradation of organics. The organic removal efficiency of the biofilter was successfully predicted using kinetics data obtained from the previous studies. The model was sensitive to the biofilm thickness and decay constant. The adsorption-membrane hybrid system is emerging as a cost-effective membrane process for the organic removal. In this system, the organics are adsorbed on the adsorbent and the organic laden adsorbents are removed by the membrane separation process. In this study, the adsorption-membrane hybrid system was evaluated using submerged hollow fibre (pore size 0.1 ~m), and the external loop crossflow rnicrofiItration. Powdered activated carbon (PAC) was used to reduce the direct organic loading onto the membrane surface. The main function of membrane in these studies was to remove the organic laden PAC particles. The submerged PAC-Membrane hybrid system was found effective in removing dissolved organic substances both from the synthetic wastewater and the biologically treated effluent of a sewage treatment plant. The system has potential for its long-term application in the treatment of wastewater without the need of frequent membrane cleaning. This preliminary study showed that the PAC-membrane hybrid system could be used for a long time effectively (over 47 days). At the initial stage of operation, the organic removal was mainly due to adsorption by PAC, but during the long-term application of the system, the adsorption capacity of the PAC was exhausted gradually, and the microbial communities developed on the PAC, in the suspension of the reactor, and on the membrane surface actively participated in the biodegradation of the organics. An empirical mathematical model was developed for the submerged hollow fibre membrane hybrid system. The model predicted the organic removal efficiency of the system satisfactorily. A new term, membrane correlation coefficient (MCC) was introduced in the model to account for the adsorption of organics onto membrane surface. The MCC and the filtration rate (flux) were found to be the main model parameters that controlled the quality of the effluent from the system. Greater the value of MCC, better was the organic removal efficiency of the system. The MCC value was found to increase with the increase in the PAC dose to the system. Since only the short-term experiments were conducted in this study, the biological degradation of the organics was not included in the model. It is necessary to incorporate the biological degradation part in the model to predict the long-term efficiency of the system. The external loop cross-flow microfiltration system with prior PAC addition was also tested using the synthetic wastewater. This study showed that the use of PAC helped not only in the organic removal but also in the enhancement of the filtration flux. The use of PAC was instrumental in increasing the operational life the membrane hybrid system by reducing the organic fouling on the membrane. The conventional pressure filtration models, cake filtration model (CFM) and standard blocking model (SBM) were used to successfully predict the experimental results. Since CFM was more effective in predicting the volume of the permeate flux from the hybrid system, one could infer that the fouling mechanism of the membrane was mainly due to the formation of cake layer on the membrane surface. However, the experimental conditions used in the hybrid system were not so favourable for removing the organics from the synthetic wastewater. The organic removal efficiency of the PAC-membrane hybrid system was only 250/0 for the PAC dose of 150 mg/L. The organic removal efficiency of the system depends mainly on the characteristics of the adsorbent and the influent wastewater solution, and the adsorbent dose. This study shows that activated carbon can effectively be used in different operational modes and in different treatment processes to remove organics from the wastewater, and to produce effluent of high quality that can be reused for many purposes.
82

Solid-liquid separation in the water and wastewater industries

Stickland, Anthony D. January 2005 (has links)
Water and wastewater treatment produce sludge that is dewatered prior to disposal in order to reduce disposal costs. This work combined mathematical modelling of thickeners, filters and centrifuges with accurate measurement of sludge dewatering properties to give improvements in operation, design and control of such devices, including increased throughput and reduced water content. / The theoretical basis of this work was the phenomenological solid-liquid separation theory of Buscall and White, 1987, in which the local volume fraction dependent properties of compressive yield stress, Py(φ), and hindered settling function, R(φ) (which, when combined, give the solids diffusivity, D(φ)), describe the material behaviour in compression. The local conservation equations were given in vector notation, converted to one-dimension, and applied to piston-driven filtration. A range of models of plate-and-frame filter presses and solid-bowl centrifuges were developed. Simple visual basic programs were written to provide operators and designers access to filter model predictions. / Filtration and settling tests were used to measure the material characteristics for water and wastewater treatment sludges from a range of industrial sites, including different coagulants and coagulation conditions, with weekly and seasonal variations. The results showed that ferric-based water treatment sludges have very little variability, while alum sludges can exhibit some changes in properties. New qualitative and quantitative methods were developed for wastewater sludges, which exhibit atypical filtration behaviour. The production of synthetic sewage sludge showed that this is caused by the extracellular polymeric constituent. / The material characteristics were used to predict the throughput and cake solids for filter presses, centrifuges and continuous thickeners. The filter models were validated at a range of water treatment plants, and used to investigate the optimisation and control of press performance. A modified-Darcy’s law, which was validated using model predictions, was used to determine the membrane resistance from on-site measurements. / The centrifuge models included one-dimensional transient and continuous, and two-dimensional continuous decanting models. Algorithms for the solution of the one-dimensional models were developed for both the un-networked and networked cases, and the results for a simple example illustrated. The development of the decanting centrifuge model included conversion of the conservation equations to helical coordinates, consideration of the viscous flow of the centrate down the spiral formed by the blades of the scroll, the movement of the solids due to differential speed of the scroll and the sedimentation-consolidation of the solids due to the centrifugal acceleration. / Civil engineering consolidation theory and testing methods were outlined and compared to filtration. The relevant dewatering parameters were related via a simple equation. The material characteristics of a kaolin sample were measured using oedometer and pressure filtration testing and compared using the derived relationship. / Overall, this represents several important developments in the understanding of water and wastewater sludge dewatering, especially the measurement of water treatment sludge characteristics at a range of sites and with seasonal variations, the development of analysis techniques to determine wastewater sludge characteristics, and the development or adaptation of new or existing models of filters, centrifuges and thickeners. Considerable cost savings were made possible by understanding both the material behaviour and the dewatering device.
83

Evaluation of an extended aeration treatment plant

McCulloch, Gary Eugene, 1944- January 1970 (has links)
No description available.
84

Municipal improvements; or, the design, specifications and advertisement for bids on complete waterworks and sewerage systems

Prichard, Robert Leo 08 1900 (has links)
No description available.
85

Stochastic control of the activated sludge process

Kabouris, John C. 08 1900 (has links)
No description available.
86

Physicochemical transformations of sewage effluent releases in an ephemeral stream channel

Sebenik, Paul Gregory, January 1975 (has links) (PDF)
Thesis (M.S. - Hydrology and Water Resources)--University of Arizona. / Includes bibliographical references.
87

A treatability comparison study of greywater and combined septic tank effluents using intermittent sand filtration

Nykiel, David Alan. January 1983 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1983. / Typescript. Title from title screen (viewed July 2, 2008). Includes bibliographical references (p. 170-175). Online version of the print original.
88

Comparison of lime and sodium hydroxide for the control of gas production from sewage sludges /

Thota, Ravi Meher, January 1991 (has links)
Thesis (M.S.)--Virginia Polytechnic Institute and State University, 1991. / Vita. Abstract. Includes bibliographical references (leaves 56-57). Also available via the Internet.
89

On-site wastewater treatment and disposal systems on reclaimed mined land /

Peterson, Craig E., January 1991 (has links)
Thesis (M.S.)--Virginia Polytechnic Institute and State University, 1991. / Vita. Abstract. Includes bibliographical references (leaves 83-89). Also available via the Internet.
90

An assessment of alternative wastewater treatment approaches in Guangzhou /

Tao, Yingxiang. January 1999 (has links)
Thesis (Ph. D.)--University of Hong Kong, 1999. / Includes bibliographical references (leaves 345-365).