Spelling suggestions: "subject:"shortduration"" "subject:"shorterdurations""
11 |
Development of New Single and High-Density Heat Flux Gauges for Unsteady Heat Transfer Measurements in a Rotating Transonic TurbineCelestina, Richard A. 06 October 2021 (has links)
No description available.
|
12 |
Confidence in initiation of breastfeedingEdwards, Margaret Ellenor January 2013 (has links)
Background: Breastfeeding confers health and social benefits on both mother and baby and is thus a key global public health priority, with exclusive breastfeeding for the first six months recommended. A variety of factors can influence a woman’s decision to initiate breastfeeding but a short duration of breastfeeding appears to be common in developed countries. In the UK, promotion of breastfeeding has been government policy since 1974 and gradually the incidence has increased. In Scotland in 2010 the incidence was 74% but by one week 17% of women had given up. A minority of women find that their babies attach easily at birth and more than half report problems at this time. The prevalence of exclusive breastfeeding falls sharply in the first few weeks and the introduction of formula is associated with a shorter duration. It is therefore crucial to understand what happens at this time to enable women to continue breastfeeding effectively. Study Aim: To use Social Cognitive Theory (SCT) to explore and help explain the expectations, knowledge and experiences of women and midwives with regard to breastfeeding initiation. Methods: A systematic review of qualitative studies synthesised using thematic analysis and SCT was conducted and afforded insight into what had been known before and highlighted further aspects that needed to be explored with a qualitative study. The qualitative study was comprised of five focus groups with ten antenatal women, eight postnatal women and eighteen midwives. Photographs included in a leaflet “Feeding cues at birth”, and the chart of “Feeding cues after the first few hours” were developed and used as focussing exercises during the focus groups and interviews. The focus groups and interviews were recorded, transcribed and analysed using a hybrid process of inductive and deductive thematic analysis which integrated data driven codes with theory driven codes based on SCT. Results: Twenty one studies were included in the systematic review and identified clear differences in the experiences of women when breastfeeding was going well as compared to when it was going wrong at the start. There were also differences in the midwives’ knowledge, experience and confidence when breastfeeding was going well in contrast to when it was going wrong. The synthesis did not identify any qualitative studies relevant to initiation which explored skin contact, instinctive behaviour or strategies to resolve failure to attach in the first few days after birth, from the perspectives of mothers and midwives. These topics were therefore explored in detail in the qualitative study. Few mothers recruited to my study experienced instinctive behaviour and successful attachment (in SCT enactive behaviour) at birth. The majority of mothers did not experience attachment at birth and struggled to persist and maintain their motivation to enable breastfeeding initiation in an unfamiliar environment. Midwives’ social expectations and environmental circumstances made women centred care difficult. Midwives considered that sleepy babies who were unable to feed were normal, but women were unprepared for this, compounding the difficulties in initiating breastfeeding. The triangulation of the findings from the systematic review and the qualitative study provide a more complete picture of contributory factors to understanding of difficulties in breastfeeding initiation. Conclusion: It is recognised that behaviour interacts with emotions, perceived abilities and the environment, as in triadic reciprocal causation, which affects peoples’ decisions, experiences and abilities to enable the successful initiation of breastfeeding. Social Cognitive Theory could be used as a framework to develop strategies and materials to enhance women’s confidence both antenatally and in the postnatal period. In a minority of women, breastfeeding goes well and is more likely when the baby is an active participant and the midwife a knowledgeable and confident supporter. This is not the case for the majority of women and babies or their midwives. There is a need to consider strategies to develop appropriate skills and environmental changes that would in turn lead to changes in behaviour and successful interventions. More emphasis should be made clinically on facilitating instinctive behaviour. The current position where babies’ sleepy behaviour is considered normal in this particular environment could be challenged. Social Cognitive Theory could be utilised in research to develop strategies to increase women’s and midwives’ confidence specifically in initiation.
|
13 |
Mitigação de variações de tensão causadas pela proteção anti-ilhamento de geradores distribuídos via controle de taps de reguladores de tensão / Mitigating voltage variations caused by the anti-islanding protection of distributed generator via voltage regulator tap controlLima, Daniel Ferreira 04 August 2017 (has links)
A conexão de geradores distribuídos em sistemas de distribuição deve ser cuidadosamente avaliada para que os mesmos auxiliem efetivamente na melhoria do desempenho das redes elétricas, buscando reduzir ou eliminar eventuais situações que causem a degradação da qualidade da energia elétrica fornecida aos consumidores, entre outros aspectos. Neste contexto, existem vários trabalhos que analisam a influência da conexão de geradores distribuídos no perfil de tensão da rede elétrica, frequência, desequilíbrio de fases e distorção harmônica. No entanto, há poucos trabalhos analisando os efeitos da desconexão de geradores distribuídos na qualidade da energia fornecida aos consumidores. Uma vez operando em paralelo com a rede de distribuição, esses geradores influenciam o perfil de tensão e o comportamento dos dispositivos reguladores de tensão. Como consequência, sua desconexão pode provocar variações de tensão intensas causando danos ou mau funcionamento às cargas. A desconexão pode ser repentina ou devido à atuação da proteção anti-ilhamento, seguida dos procedimentos de religamento automático do alimentador, se houver. Visando estudar este problema, o qual tende a se tornar uma nova preocupação das concessionárias de energia elétrica, e no intuito de minimizar e/ou eliminar os possíveis efeitos negativos dessas variações de tensão, esta pesquisa propõe o desenvolvimento de um método de controle dos taps dos reguladores de tensão. Neste método, o controle dos taps foi modelado como um problema de otimização, minimizando as violações de tensão mencionadas anteriormente e também a quantidade de operações dos reguladores de tensão ao longo de um dia típico. A otimização foi solucionada com um Algoritmo Genético e os resultados obtidos indicaram que é possível minimizar as variações de tensão usando a curva de carga do sistema para planejar a operação dos reguladores de tensão. / The connection of distributed generators in an electric power system should be evaluated carefully to ensure that they effectively assist in improving the performance of electrical networks, reducing or eliminating any situations that cause degradation of the power quality of the consumers, and other issues. In this context, there are several studies that analyze the influence of generators connected to distribution systems and how they affect the frequency, cause variations in voltage magnitude, voltage unbalance and harmonic distortion. However, there are a few studies analyzing the effects that the disconnection of distributed generators induces to the power quality of consumers. Once operating in parallel with the distribution network, these generators have an effect on voltage variations and voltage regulator devices. As a result, disconnection can cause severe voltage variations causing damage or malfunction to the loads. The disconnection may be sudden or due to the action of anti-islanding protection, followed by the procedure to reconnect the substation, if it is possible. In order to study this problem, which tends to become a new power quality concern for electric utilities, and in order to minimize and / or eliminate the possible side effects of the voltage variations, this research proposes the development of a control method of voltage regulators\' taps. In this method, the control of taps was modeled as an optimization problem which aimed to minimize these voltage variations aforementioned and also the amount of voltage regulator operations over a typical day. The optimization was solved by a Genetic Algorithm and the results obtained demonstrate that it is possible to minimize the voltage variation by using the system load curve to plan the operation of voltage regulators.
|
14 |
Análise da robustez e da sensibilidade de sistemas de distribuição para a alocação otimizada de medidores frente às variações de tensão de curta duração / Analysis of the robustness and sensitivity of distribution systems for optimal allocation of monitors in face of Short Duration Voltage VariationsKempner, Thais Reggina 19 May 2016 (has links)
Como as Variações de Tensão de Curta Duração (VTCDs) estão entre as perturbações mais difíceis de serem monitoradas, uma vez que são ocasionadas por fatores aleatórios e imprevisíveis, a monitoração do Sistema de Distribuição (SD) representa uma providência essencial para a obtenção de informações representativas para a regulamentação de novos indicadores relativos a esses distúrbios. Neste cenário, este trabalho busca garantir a completa observabilidade das VTCDs em SD, quando da incidência de qualquer tipo de curto-circuito, através da alocação ótima de medidores. Para a determinação da magnitude da tensão em cada nó do SD é utilizado o método das posições de falta, denotando assim, a influência e a propagação das VTCDs sobre a rede como um todo. Na sequência, é determinada uma matriz binária resultante que observa os afundamentos de tensão de forma simultânea para todos os tipos de faltas. Posteriormente, é proposta a redução desta matriz para diminuir o esforço computacional em SDs de grande porte. Ainda, é analisada a vulnerabilidade de cada nó do SD para estabelecer a sua posterior ponderação no processo de otimização. Os resultados revelam que a metodologia de alocação apresentada torna o processo de obtenção da solução ótima ágil e direto, pois menos execuções computacionais são necessárias para obter diferentes soluções ótimas e garantir a monitoração dos afundamentos de tensão para todos os tipos de curtos-circuitos. Além disso, pela metodologia, tem-se também a prioridade de instalação dos medidores conforme a maior observabilidade dos afundamentos de tensão, possibilitando a escolha do melhor arranjo de medidores que atenda aos limites orçamentários das distribuidoras de energia. / Short Duration Voltage Variations (SDVVs) are among the most difficult disturbances to be monitored, since they are caused by random and unpredictable factors. Hence, the Distribution System (DS) monitoring is an essential step for obtaining representative information for the regulation of new power quality indices for these disturbances. In this scenario, this work aims to ensure the entire observability of SDVVs, considering any short circuit occurrence in the DS, based on algorithm to achieve the monitors\' optimal allocation. In order to determine the voltage magnitude at each node, the fault positions method is used, showing the influence and propagation of SDVVs on the DS. Subsequently, a resulting binary matrix is determined. This matrix observes the voltage sags, simultaneously, for all fault types. Then, the downsizing of this matrix is proposed in order to reduce the computational effort in large DSs. Furthermore, the vulnerability of each DS node is analyzed to establish the relative weighting in the optimization process. The results show a faster and more direct allocation methodology to obtain the optimal solution, because fewer computational executions are needed for different optimal solutions and to ensure the voltage sags monitoring for all short circuits types. Moreover, the power quality monitor installation priority is performed according to the higher observability of the voltage sags, making it possible to choose the best arrangement of monitors that meets the budget constraints of the power utilities.
|
15 |
Estimador de variações de tensão de curta duração em sistemas elétricos de potência utilizando estratégias evolutivas. / Estimate short duration voltage variation using evolutionary strategies.Guerra Zvietcovich, Wilingthon 19 September 2011 (has links)
Neste trabalho, é proposta uma metodologia para estimar o estado de um sistema elétrico de potência (SEPs) durante variações de tensão de curta duração (VTCDs) causadas por faltas elétricas nas linhas que compõem a rede elétrica avaliada. Para cumprir esta meta, são utilizados os valores registrados nos equipamentos de medição instalados nas redes elétricas. Na realidade, existem poucos equipamentos nas redes elétricas devido aos custos elevados dos medidores de qualidade de energia elétrica (QEE). Embora estes custos tenham diminuído nos últimos anos, ainda é inviável a utilização de um número suficiente de medidores para garantir a monitoração de toda a rede, por tornar-se muito oneroso. Esta realidade constitui um desafio para se desenvolver técnicas que permitam, a partir de um pequeno número de pontos de monitoração, determinar os locais de faltas e estimar os valores das VTCDs em todas as barras que compõem um sistema elétrico. Como contribuição à solução destes problemas, esta tese propõe a utilização do algoritmo denominado Estratégias Evolutivas (EEs), que integra a família dos Algoritmos Evolutivos. Tal algoritmo mostrou ser viável por sua facilidade de implementação e rapidez de resposta na busca de uma solução dentro de um vasto espaço de soluções. As EEs, nesta tese, são utilizadas para se determinar: o local de falta, tipo de falta e impedância de falta, que caracterizam um indivíduo, de forma que as tensões resultantes nas barras monitoradas sejam as mais próximas possíveis das medições realizadas. Para alcançar esse objetivo, inicialmente se constrói uma população inicial de indivíduos que representam alternativas de solução do problema. Em seguida, uma parte destes indivíduos será submetida a mutação e recombinação para então serem selecionados os indivíduos que sobreviverão na geração futura. Este processo iterativo é realizado até que se encontre uma solução o mais próximo da procurada. Cada indivíduo é avaliado através de função objetivo, que representa o erro quadrático entre os valores medidos e os valores calculados. Para este cálculo, é necessário simular um curto-circuito com as características do indivíduo avaliado com base em informações da rede bem como dos valores das tensões provenientes dos medidores. A partir da determinação das características da falta, é feita a estimação dos valores das tensões em toda a rede levando à avaliação das VTCDs. Uma vez atingido este objetivo, é possível, por exemplo, determinar indicadores de qualidade associados às VTCDs, como o SARFI (System Average RMS Frequency Index), determinar as áreas mais propensas a causar as VTCDs e elaborar planos de manutenção preventiva. Foram implementados dois algoritmos que calculam o número mínimo de medidores e os locais onde estes devem ser instalados. O primeiro algoritmo tem a finalidade de garantir o monitoramento de toda a rede em relação às VTCDs enquanto o segundo garante o menor erro de estimação de VTCDs nas barras onde não se têm medidores instalados. A referida metodologia pode ser aplicada em redes radiais ou em malha, sendo inicialmente aplicada em sistemas de pequeno porte (redes de 14 e 30 barras do IEEE) com intuito de verificar a capacidade do algoritmo. Foram então simuladas redes de maior complexidade, por meio de testes em redes de 57 barras e 118 barras do IEEE. Para avaliar a eficiência da metodologia desenvolvida foi feita uma comparação com outra metodologia de otimização baseada em Algoritmos Genéticos (AGs). / A methodology is herein proposed to estimate Short Duration Voltage Variation (SDVV) in electric power systems, caused by electrical faults. To attain this target, values recorded by measurement equipment in specific sites are used. In fact, there are few power quality meters installed in power networks, due to the high cost of such meters. Although these costs have decreased in recent years, the installation of a sufficient number of meters to ensure monitoring the entire network is still unfeasible. This reality poses a challenge to developing techniques that, with a small number of monitoring points, allow the determination of fault locations and estimation of SDVV values in specified buses. As contribution this thesis proposes an algorithm called Evolutionary Strategies (ESE), which integrates the group of evolutionary algorithms. This algorithm can be easily implemented and finds a solution within a wide solution space. The ESE determines the fault location, fault type and fault impedance, that characterize an individual, so that the resulting voltages on monitored buses are as close as possible to the measured ones. An initial population is generated as alternative solutions to the problem. Some of the individuals in the population will be submitted to mutation and recombination operators. Individuals are then selected to the future generation. An iterative process is carried out to determine a solution as close as possible to the desired one. Each individual is evaluated by the objective function, which represents the quadratic error between the measured and calculated values. This calculation is based on short circuit calculation related to the evaluated individual and from information of voltage values gathered from power quality meters. Voltage values in specific network buses can then be determined to monitor their corresponding SDVV values. This allows, for example, determining quality indicators associated to the SDVV, such as the System Average RMS Frequency Index (SARFI), to evaluate sensitive areas, i.e. which are prone to cause SDVVs and to develop plans for preventive maintenance. Two algorithms that calculate the minimum number of meters and their locations have been implemented. The first algorithm aims to ensure monitoring the entire network regarding SDVVs, while the second algorithm ensures the smallest error of SDVV estimation in buses where no meters are installed. This methodology can be applied to meshed or radial networks. It was initially implemented in small networks (IEEE 14 and 30 buses) with the purpose of verifying the ability of algorithm. In sequence the methodology was applied to more complex networks (IEEE 57 and 118 buses). To assess the efficiency of the methodology a comparison with other optimization methodology based on Genetic Algorithms (GA) was carried out.
|
16 |
Resposta dinâmica dos motores de indução trifásicos a afundamentos de tensão na rede de alimentação / Dynamic response of three-phase induction motors to voltage sags in the power supply networkGibelli, Gerson Bessa 04 June 2009 (has links)
Esta pesquisa apresenta um estudo da resposta dinâmica dos motores de indução trifásicos submetidos a afundamentos de tensão. As simulações computacionais sobre um sistema de distribuição, assim como a modelagem dos motores de indução trifásicos baseada em dados reais, foram realizadas utilizando-se do software ATP (Alternative Transients Program). Estas tiveram por objetivo gerar situações representativas da operação do sistema elétrico de potência (SEP), caracterizando afundamentos de tensão, fenômenos estes pertencentes à classe de variações de tensão de curta duração (VTCD), no contexto da qualidade da energia elétrica (QEE). Da observação destes afundamentos, verificaram-se as situações que vieram ou não, a comprometer a alimentação do equipamento analisado e, conseqüentemente, seu desempenho. Pelos resultados observados, evidencia-se que a metodologia de análise aplicada é satisfatória e condizente com o encontrado em situações reais de operação dos motores de indução trifásicos, denotando certas características intrínsecas no contexto das VTCDs. / This research shows a study on the dynamic response of three-phase induction motors submitted to voltage sags. Computer simulations about a distribution system, as well as the modeling of three-phase induction motors based on actual data, were made using ATP (Alternative Transients Program) software. These simulations intended to generate representative situations of the electrical power system (EPS) operation, characterizing voltage sags, which is a phenomenon belonging to the class of short duration voltage variations (SDVV), in the electrical power quality context (EPQ). From the observation of these sags, we verified the situations that jeopardized or not the supply of the analyzed equipment and, consequently, its performance. From the observed results, it becomes evident that the methodology of the applied analysis is satisfactory and in agreement with the one found in actual situations of three-phase induction motors operations, indicating certain characteristics intrinsic to the SDVV context.
|
17 |
Resposta dinâmica dos motores de indução trifásicos a afundamentos de tensão na rede de alimentação / Dynamic response of three-phase induction motors to voltage sags in the power supply networkGerson Bessa Gibelli 04 June 2009 (has links)
Esta pesquisa apresenta um estudo da resposta dinâmica dos motores de indução trifásicos submetidos a afundamentos de tensão. As simulações computacionais sobre um sistema de distribuição, assim como a modelagem dos motores de indução trifásicos baseada em dados reais, foram realizadas utilizando-se do software ATP (Alternative Transients Program). Estas tiveram por objetivo gerar situações representativas da operação do sistema elétrico de potência (SEP), caracterizando afundamentos de tensão, fenômenos estes pertencentes à classe de variações de tensão de curta duração (VTCD), no contexto da qualidade da energia elétrica (QEE). Da observação destes afundamentos, verificaram-se as situações que vieram ou não, a comprometer a alimentação do equipamento analisado e, conseqüentemente, seu desempenho. Pelos resultados observados, evidencia-se que a metodologia de análise aplicada é satisfatória e condizente com o encontrado em situações reais de operação dos motores de indução trifásicos, denotando certas características intrínsecas no contexto das VTCDs. / This research shows a study on the dynamic response of three-phase induction motors submitted to voltage sags. Computer simulations about a distribution system, as well as the modeling of three-phase induction motors based on actual data, were made using ATP (Alternative Transients Program) software. These simulations intended to generate representative situations of the electrical power system (EPS) operation, characterizing voltage sags, which is a phenomenon belonging to the class of short duration voltage variations (SDVV), in the electrical power quality context (EPQ). From the observation of these sags, we verified the situations that jeopardized or not the supply of the analyzed equipment and, consequently, its performance. From the observed results, it becomes evident that the methodology of the applied analysis is satisfactory and in agreement with the one found in actual situations of three-phase induction motors operations, indicating certain characteristics intrinsic to the SDVV context.
|
18 |
Mitigação de variações de tensão causadas pela proteção anti-ilhamento de geradores distribuídos via controle de taps de reguladores de tensão / Mitigating voltage variations caused by the anti-islanding protection of distributed generator via voltage regulator tap controlDaniel Ferreira Lima 04 August 2017 (has links)
A conexão de geradores distribuídos em sistemas de distribuição deve ser cuidadosamente avaliada para que os mesmos auxiliem efetivamente na melhoria do desempenho das redes elétricas, buscando reduzir ou eliminar eventuais situações que causem a degradação da qualidade da energia elétrica fornecida aos consumidores, entre outros aspectos. Neste contexto, existem vários trabalhos que analisam a influência da conexão de geradores distribuídos no perfil de tensão da rede elétrica, frequência, desequilíbrio de fases e distorção harmônica. No entanto, há poucos trabalhos analisando os efeitos da desconexão de geradores distribuídos na qualidade da energia fornecida aos consumidores. Uma vez operando em paralelo com a rede de distribuição, esses geradores influenciam o perfil de tensão e o comportamento dos dispositivos reguladores de tensão. Como consequência, sua desconexão pode provocar variações de tensão intensas causando danos ou mau funcionamento às cargas. A desconexão pode ser repentina ou devido à atuação da proteção anti-ilhamento, seguida dos procedimentos de religamento automático do alimentador, se houver. Visando estudar este problema, o qual tende a se tornar uma nova preocupação das concessionárias de energia elétrica, e no intuito de minimizar e/ou eliminar os possíveis efeitos negativos dessas variações de tensão, esta pesquisa propõe o desenvolvimento de um método de controle dos taps dos reguladores de tensão. Neste método, o controle dos taps foi modelado como um problema de otimização, minimizando as violações de tensão mencionadas anteriormente e também a quantidade de operações dos reguladores de tensão ao longo de um dia típico. A otimização foi solucionada com um Algoritmo Genético e os resultados obtidos indicaram que é possível minimizar as variações de tensão usando a curva de carga do sistema para planejar a operação dos reguladores de tensão. / The connection of distributed generators in an electric power system should be evaluated carefully to ensure that they effectively assist in improving the performance of electrical networks, reducing or eliminating any situations that cause degradation of the power quality of the consumers, and other issues. In this context, there are several studies that analyze the influence of generators connected to distribution systems and how they affect the frequency, cause variations in voltage magnitude, voltage unbalance and harmonic distortion. However, there are a few studies analyzing the effects that the disconnection of distributed generators induces to the power quality of consumers. Once operating in parallel with the distribution network, these generators have an effect on voltage variations and voltage regulator devices. As a result, disconnection can cause severe voltage variations causing damage or malfunction to the loads. The disconnection may be sudden or due to the action of anti-islanding protection, followed by the procedure to reconnect the substation, if it is possible. In order to study this problem, which tends to become a new power quality concern for electric utilities, and in order to minimize and / or eliminate the possible side effects of the voltage variations, this research proposes the development of a control method of voltage regulators\' taps. In this method, the control of taps was modeled as an optimization problem which aimed to minimize these voltage variations aforementioned and also the amount of voltage regulator operations over a typical day. The optimization was solved by a Genetic Algorithm and the results obtained demonstrate that it is possible to minimize the voltage variation by using the system load curve to plan the operation of voltage regulators.
|
19 |
Estimador de variações de tensão de curta duração em sistemas elétricos de potência utilizando estratégias evolutivas. / Estimate short duration voltage variation using evolutionary strategies.Wilingthon Guerra Zvietcovich 19 September 2011 (has links)
Neste trabalho, é proposta uma metodologia para estimar o estado de um sistema elétrico de potência (SEPs) durante variações de tensão de curta duração (VTCDs) causadas por faltas elétricas nas linhas que compõem a rede elétrica avaliada. Para cumprir esta meta, são utilizados os valores registrados nos equipamentos de medição instalados nas redes elétricas. Na realidade, existem poucos equipamentos nas redes elétricas devido aos custos elevados dos medidores de qualidade de energia elétrica (QEE). Embora estes custos tenham diminuído nos últimos anos, ainda é inviável a utilização de um número suficiente de medidores para garantir a monitoração de toda a rede, por tornar-se muito oneroso. Esta realidade constitui um desafio para se desenvolver técnicas que permitam, a partir de um pequeno número de pontos de monitoração, determinar os locais de faltas e estimar os valores das VTCDs em todas as barras que compõem um sistema elétrico. Como contribuição à solução destes problemas, esta tese propõe a utilização do algoritmo denominado Estratégias Evolutivas (EEs), que integra a família dos Algoritmos Evolutivos. Tal algoritmo mostrou ser viável por sua facilidade de implementação e rapidez de resposta na busca de uma solução dentro de um vasto espaço de soluções. As EEs, nesta tese, são utilizadas para se determinar: o local de falta, tipo de falta e impedância de falta, que caracterizam um indivíduo, de forma que as tensões resultantes nas barras monitoradas sejam as mais próximas possíveis das medições realizadas. Para alcançar esse objetivo, inicialmente se constrói uma população inicial de indivíduos que representam alternativas de solução do problema. Em seguida, uma parte destes indivíduos será submetida a mutação e recombinação para então serem selecionados os indivíduos que sobreviverão na geração futura. Este processo iterativo é realizado até que se encontre uma solução o mais próximo da procurada. Cada indivíduo é avaliado através de função objetivo, que representa o erro quadrático entre os valores medidos e os valores calculados. Para este cálculo, é necessário simular um curto-circuito com as características do indivíduo avaliado com base em informações da rede bem como dos valores das tensões provenientes dos medidores. A partir da determinação das características da falta, é feita a estimação dos valores das tensões em toda a rede levando à avaliação das VTCDs. Uma vez atingido este objetivo, é possível, por exemplo, determinar indicadores de qualidade associados às VTCDs, como o SARFI (System Average RMS Frequency Index), determinar as áreas mais propensas a causar as VTCDs e elaborar planos de manutenção preventiva. Foram implementados dois algoritmos que calculam o número mínimo de medidores e os locais onde estes devem ser instalados. O primeiro algoritmo tem a finalidade de garantir o monitoramento de toda a rede em relação às VTCDs enquanto o segundo garante o menor erro de estimação de VTCDs nas barras onde não se têm medidores instalados. A referida metodologia pode ser aplicada em redes radiais ou em malha, sendo inicialmente aplicada em sistemas de pequeno porte (redes de 14 e 30 barras do IEEE) com intuito de verificar a capacidade do algoritmo. Foram então simuladas redes de maior complexidade, por meio de testes em redes de 57 barras e 118 barras do IEEE. Para avaliar a eficiência da metodologia desenvolvida foi feita uma comparação com outra metodologia de otimização baseada em Algoritmos Genéticos (AGs). / A methodology is herein proposed to estimate Short Duration Voltage Variation (SDVV) in electric power systems, caused by electrical faults. To attain this target, values recorded by measurement equipment in specific sites are used. In fact, there are few power quality meters installed in power networks, due to the high cost of such meters. Although these costs have decreased in recent years, the installation of a sufficient number of meters to ensure monitoring the entire network is still unfeasible. This reality poses a challenge to developing techniques that, with a small number of monitoring points, allow the determination of fault locations and estimation of SDVV values in specified buses. As contribution this thesis proposes an algorithm called Evolutionary Strategies (ESE), which integrates the group of evolutionary algorithms. This algorithm can be easily implemented and finds a solution within a wide solution space. The ESE determines the fault location, fault type and fault impedance, that characterize an individual, so that the resulting voltages on monitored buses are as close as possible to the measured ones. An initial population is generated as alternative solutions to the problem. Some of the individuals in the population will be submitted to mutation and recombination operators. Individuals are then selected to the future generation. An iterative process is carried out to determine a solution as close as possible to the desired one. Each individual is evaluated by the objective function, which represents the quadratic error between the measured and calculated values. This calculation is based on short circuit calculation related to the evaluated individual and from information of voltage values gathered from power quality meters. Voltage values in specific network buses can then be determined to monitor their corresponding SDVV values. This allows, for example, determining quality indicators associated to the SDVV, such as the System Average RMS Frequency Index (SARFI), to evaluate sensitive areas, i.e. which are prone to cause SDVVs and to develop plans for preventive maintenance. Two algorithms that calculate the minimum number of meters and their locations have been implemented. The first algorithm aims to ensure monitoring the entire network regarding SDVVs, while the second algorithm ensures the smallest error of SDVV estimation in buses where no meters are installed. This methodology can be applied to meshed or radial networks. It was initially implemented in small networks (IEEE 14 and 30 buses) with the purpose of verifying the ability of algorithm. In sequence the methodology was applied to more complex networks (IEEE 57 and 118 buses). To assess the efficiency of the methodology a comparison with other optimization methodology based on Genetic Algorithms (GA) was carried out.
|
20 |
Análise da robustez e da sensibilidade de sistemas de distribuição para a alocação otimizada de medidores frente às variações de tensão de curta duração / Analysis of the robustness and sensitivity of distribution systems for optimal allocation of monitors in face of Short Duration Voltage VariationsThais Reggina Kempner 19 May 2016 (has links)
Como as Variações de Tensão de Curta Duração (VTCDs) estão entre as perturbações mais difíceis de serem monitoradas, uma vez que são ocasionadas por fatores aleatórios e imprevisíveis, a monitoração do Sistema de Distribuição (SD) representa uma providência essencial para a obtenção de informações representativas para a regulamentação de novos indicadores relativos a esses distúrbios. Neste cenário, este trabalho busca garantir a completa observabilidade das VTCDs em SD, quando da incidência de qualquer tipo de curto-circuito, através da alocação ótima de medidores. Para a determinação da magnitude da tensão em cada nó do SD é utilizado o método das posições de falta, denotando assim, a influência e a propagação das VTCDs sobre a rede como um todo. Na sequência, é determinada uma matriz binária resultante que observa os afundamentos de tensão de forma simultânea para todos os tipos de faltas. Posteriormente, é proposta a redução desta matriz para diminuir o esforço computacional em SDs de grande porte. Ainda, é analisada a vulnerabilidade de cada nó do SD para estabelecer a sua posterior ponderação no processo de otimização. Os resultados revelam que a metodologia de alocação apresentada torna o processo de obtenção da solução ótima ágil e direto, pois menos execuções computacionais são necessárias para obter diferentes soluções ótimas e garantir a monitoração dos afundamentos de tensão para todos os tipos de curtos-circuitos. Além disso, pela metodologia, tem-se também a prioridade de instalação dos medidores conforme a maior observabilidade dos afundamentos de tensão, possibilitando a escolha do melhor arranjo de medidores que atenda aos limites orçamentários das distribuidoras de energia. / Short Duration Voltage Variations (SDVVs) are among the most difficult disturbances to be monitored, since they are caused by random and unpredictable factors. Hence, the Distribution System (DS) monitoring is an essential step for obtaining representative information for the regulation of new power quality indices for these disturbances. In this scenario, this work aims to ensure the entire observability of SDVVs, considering any short circuit occurrence in the DS, based on algorithm to achieve the monitors\' optimal allocation. In order to determine the voltage magnitude at each node, the fault positions method is used, showing the influence and propagation of SDVVs on the DS. Subsequently, a resulting binary matrix is determined. This matrix observes the voltage sags, simultaneously, for all fault types. Then, the downsizing of this matrix is proposed in order to reduce the computational effort in large DSs. Furthermore, the vulnerability of each DS node is analyzed to establish the relative weighting in the optimization process. The results show a faster and more direct allocation methodology to obtain the optimal solution, because fewer computational executions are needed for different optimal solutions and to ensure the voltage sags monitoring for all short circuits types. Moreover, the power quality monitor installation priority is performed according to the higher observability of the voltage sags, making it possible to choose the best arrangement of monitors that meets the budget constraints of the power utilities.
|
Page generated in 0.1023 seconds