Avaliação do desgaste das lâminas de corte do sistema Reciproc através da utilização do microscópio eletrônico de varredura MEV / Evaluation of wear of the cutting blades Reciproc system using the scanning electron microscope SEM

França, Rodrigo Casasanta 20 August 2013 (has links)
Quando se utilizam os instrumentos rotatórios, oscilatórios e os recíprocos, de NiTi (Níquel-Titânio), cortando ou raspando as paredes do conduto radicular, estes também sofrem desgastes em suas lâminas de corte. Tal ocorrência determina atritos cada vez maiores, proporcionais à perda do corte de suas lâminas, diminuindo a eficiência do instrumento, exigindo mais torques e força de penetração, aumentando ainda mais o atrito e o esforço que este sofre para desgastar a dentina, predispondo acidentes. O presente estudo avaliou o desgaste nas lâminas de corte das limas Reciproc, após 3,6 e 9 usos em canais de dentes naturais. Foram utilizados 180 dentes pré-molares inferiores e 40 instrumentos R40. Após o preparo dos canais os instrumentos foram incluídos em corpos de prova e submetidos a cortes transversais a 3 mm e 6 mm, contados a partir da ponta do instrumento. Nas imagens dessas secções transversais obtidas no MEV foi mesurada a distância entre as extremidades das lâminas de corte. O desgaste dos instrumentos foi estabelecido pela diferença entre as medidas das distâncias dos instrumentos sem uso com a média de cada instrumento, nos diferentes grupos experimentais. Observou-se diferença significante, quando comparados os grupos de 6 e 9 usos com o grupo controle. Já o grupo com 3 utilizações não apresentou diferença estatisticamente significante em relação ao grupo controle. As diferenças percentuais de desgaste a 3 mm após 3, 6 e 9 utilizações foram de 5,96%, 8,01% e 18,09%, respectivamente, em relação ao Grupo controle. As diferenças percentuais de desgaste a 6 mm, após 3, 6 e 9 utilizações foram de 2,32%, 9,54% e 21,00%, respectivamente, em relação ao Grupo controle. Conclui-se, assim, que ocorre desgaste significante das lâminas de corte dos instrumentos Reciproc, já a partir do terceiro uso reforçando a recomendação do fabricante em utilizar cada instrumento em molar e, então, descartá-lo. Palavras-chave: Microscopia eletrônica de varredura. Sistema Rotatório. / The fracture of nickel-titanium instrument, whose consequences can range from the difficulty of its removal until the absolute inaccessibility to the apical portion of the canal, remains a situation to be avoided in the safest way possible. When using the rotary instruments, and reciprocal oscillatory, NiTi, cutting or scraping the walls of the root canal, they also suffer wear in its cutting blades. Such an occurrence determines friction increasing in proportion to the loss of cutting blades, reducing the efficiency of the instrument, requiring higher torque and penetration force, further increasing friction and effort that suffers when wearing the dentin. Different rotational speeds to the long axis of the active part of the instrument are thus provoked in areas of high friction, favoring fractures, regardless of the type of movement, even if it is rotating or reciprocating. The present study sought to assess whether there is wear on cutting blades System Reciproc, since this system works through reciprocal movement within the root canal. For that, we will instrumentation in selected teeth with the kinematic system recommended by the manufacturer at zero, three, six and nine uses, corresponding to a molar tooth, two molar teeth and three molar teeth after 10 uses in each experimental group (zero , three, six and nine) according to the number of uses. The instruments are inserted into a quadrangular centralized device in the same position, and fixed in resin, which have been cut into their cross initial 3 mm and 6 mm initial these selected samples with the cross section of the system is brought to the SEM, and thus wear measured by measuring the radius of your cutting blades, and thus statistically analyzed. The results showed statistically significant differences after successive instrumentations.
2

Avaliação do desgaste das lâminas de corte do sistema Reciproc através da utilização do microscópio eletrônico de varredura MEV / Evaluation of wear of the cutting blades Reciproc system using the scanning electron microscope SEM

Rodrigo Casasanta França 20 August 2013 (has links)
Quando se utilizam os instrumentos rotatórios, oscilatórios e os recíprocos, de NiTi (Níquel-Titânio), cortando ou raspando as paredes do conduto radicular, estes também sofrem desgastes em suas lâminas de corte. Tal ocorrência determina atritos cada vez maiores, proporcionais à perda do corte de suas lâminas, diminuindo a eficiência do instrumento, exigindo mais torques e força de penetração, aumentando ainda mais o atrito e o esforço que este sofre para desgastar a dentina, predispondo acidentes. O presente estudo avaliou o desgaste nas lâminas de corte das limas Reciproc, após 3,6 e 9 usos em canais de dentes naturais. Foram utilizados 180 dentes pré-molares inferiores e 40 instrumentos R40. Após o preparo dos canais os instrumentos foram incluídos em corpos de prova e submetidos a cortes transversais a 3 mm e 6 mm, contados a partir da ponta do instrumento. Nas imagens dessas secções transversais obtidas no MEV foi mesurada a distância entre as extremidades das lâminas de corte. O desgaste dos instrumentos foi estabelecido pela diferença entre as medidas das distâncias dos instrumentos sem uso com a média de cada instrumento, nos diferentes grupos experimentais. Observou-se diferença significante, quando comparados os grupos de 6 e 9 usos com o grupo controle. Já o grupo com 3 utilizações não apresentou diferença estatisticamente significante em relação ao grupo controle. As diferenças percentuais de desgaste a 3 mm após 3, 6 e 9 utilizações foram de 5,96%, 8,01% e 18,09%, respectivamente, em relação ao Grupo controle. As diferenças percentuais de desgaste a 6 mm, após 3, 6 e 9 utilizações foram de 2,32%, 9,54% e 21,00%, respectivamente, em relação ao Grupo controle. Conclui-se, assim, que ocorre desgaste significante das lâminas de corte dos instrumentos Reciproc, já a partir do terceiro uso reforçando a recomendação do fabricante em utilizar cada instrumento em molar e, então, descartá-lo. Palavras-chave: Microscopia eletrônica de varredura. Sistema Rotatório. / The fracture of nickel-titanium instrument, whose consequences can range from the difficulty of its removal until the absolute inaccessibility to the apical portion of the canal, remains a situation to be avoided in the safest way possible. When using the rotary instruments, and reciprocal oscillatory, NiTi, cutting or scraping the walls of the root canal, they also suffer wear in its cutting blades. Such an occurrence determines friction increasing in proportion to the loss of cutting blades, reducing the efficiency of the instrument, requiring higher torque and penetration force, further increasing friction and effort that suffers when wearing the dentin. Different rotational speeds to the long axis of the active part of the instrument are thus provoked in areas of high friction, favoring fractures, regardless of the type of movement, even if it is rotating or reciprocating. The present study sought to assess whether there is wear on cutting blades System Reciproc, since this system works through reciprocal movement within the root canal. For that, we will instrumentation in selected teeth with the kinematic system recommended by the manufacturer at zero, three, six and nine uses, corresponding to a molar tooth, two molar teeth and three molar teeth after 10 uses in each experimental group (zero , three, six and nine) according to the number of uses. The instruments are inserted into a quadrangular centralized device in the same position, and fixed in resin, which have been cut into their cross initial 3 mm and 6 mm initial these selected samples with the cross section of the system is brought to the SEM, and thus wear measured by measuring the radius of your cutting blades, and thus statistically analyzed. The results showed statistically significant differences after successive instrumentations.
3

Avaliação por meio da microscopia eletrônica de varredura da limpeza e deformação de instrumentos rotários após a instrumentação de canais radiculares / Evaluation by scanning electron microscopy of cleaning and deformation of rotary instruments after use

Consolmagno, Elaine Cristina 21 November 2011 (has links)
O presente estudo teve como objetivo avaliar, por meio da microscopia eletrônica de varredura (M.E.V.), a remoção de detritos e deformação superficial sofrida pelos sistemas endodônticos rotatórios de NiTi BioRace (BR); Protaper (PT) e Twisted File (TF) após cada uso, totalizando cinco usos, simulando as condições clínicas. Um total de 75 molares superiores humanos extraídos cuja raiz disto-vestibular apresentava curvatura de 0 a 5° e mésio-vestibular entre 20 e 30° de acordo com o método de Weine, foram selecionados e divididos em três grupos com 25 espécimes. Para o grupo I: realizou-se instrumentação com o sistema BR; para o grupo II com o sistema PT e para o grupo III, com o TF. Foram utilizadas cinco caixas de cada sistema rotatório para instrumentar os canais mesio e distovestibulares. Inicialmente os instrumentos foram fotografados em M.E.V. com aumento de 35 vezes, utilizados uma vez e em seguida passaram por um protocolo de limpeza baseado no proposto por Parashos, Linsuwanont e Messer (2004) previamente a esterilização e, em seguida eram analisados em M.E.V., antes do uso seguinte. Esses procedimentos foram realizados até o último uso. Os dados de limpeza foram submetidos ao teste estatístico de Kruskal Wallis para comparação global e ao teste de Dunn para comparação individual dos grupos, enquanto para análise da deformação foram submetidos ao teste estatístico do Qui-quadrado para comparação global e ao teste exato de Fisher para as comparações individuais, todos com significância de 5%. Os resultados apontaram diferenças estatisticamente significantes quanto à limpeza para o sistema BR com maior quantidade de detritos remanescentes do processo de fabricação em relação ao PT e TF; após os 5 usos, os sistemas BR e PT apresentavam-se mais limpos em relação ao início do experimento, enquanto o TF permaneceu com quantidade semelhante de detritos superficiais. Ocorreu deformação em 40% do sistema BR, sendo 5% fratura e, 100% do TF, sendo 40% fratura. O sistema PT não sofreu danos consideráveis de acordo com os critérios avaliados. Por meio dos resultados obtidos neste estudo, concluiu-se que o protocolo de limpeza utilizado não proporcionou superfícies completamente limpas tanto no decorrer quanto ao final do experimento e quanto a deformação superficial, o sistema TF apresentou o pior resultado, seguido do BR, enquanto o PT que não apresentou qualquer deformação quanto aos critérios avaliados. / The aim of this study was to evaluate by scanning electron microscopy (SEM) the debris removal and deformation surface by rotary NiTi endodontic systems BioRace (BR), Protaper (PT) and Twisted File (TF) before each use, total five uses, simulating clinical conditions. A total of 75 extracted human molars whose disto-vestibular roots had curvature between 0 and 5 degrees and mesio-vestibular roots had curvature between 20 and 30 degrees according to the Weine method were selected and divided into three groups of 25 specimens. In the Group I: was used the BR system, group II was used the PT system and group III was used the TF system to shaping the mesio and distovestibular molars canals. Were used a total of five boxes to each rotary system. Initially, the instruments were examined by SEM at a magnification of 35x, then used into root canals and submitted through the cleaning protocol based on proposed by Parashos, Linsuwanont and Messer (2004) prior to sterilization for further examination by SEM, before the next use. These procedures were carried out until the last use. The cleaning data were analysed using statistical Kruskal Wallis test for global comparison and the Dunn test for individual groups comparison. The deformation data were analysed using Chi-square test for overall comparison and Fisher exact test for individual comparisons, both with 5% significance. The results showed the following statistically significant differences regarding cleaning to BR system with highest amount of debris remaining from the manufacturing process in relation to the PT and TF; after the five uses, the BR and PT systems were cleaner in relation to the initial experiment, but the TF system had the same debris amount. The deformation occurred in 40% of the BR system, with 5% fractured and 100% of the TF, with 40% fractured. The PT system has not suffered considerable damage in accordance with the criteria evaluated. The results of this study showed that the protocol did not provide cleaning surfaces completely free of debris, especially in the TF system, while for the BR and PT, resulting in cleaner surfaces at the end of the experiment compared with the dirt initial (immediately removed from their packaging). The surface deformation of TF system presented the worst results, followed by the BR and PT did not show any deformation on the criteria evaluated.
4

Avaliação por meio da microscopia eletrônica de varredura da limpeza e deformação de instrumentos rotários após a instrumentação de canais radiculares / Evaluation by scanning electron microscopy of cleaning and deformation of rotary instruments after use

Elaine Cristina Consolmagno 21 November 2011 (has links)
O presente estudo teve como objetivo avaliar, por meio da microscopia eletrônica de varredura (M.E.V.), a remoção de detritos e deformação superficial sofrida pelos sistemas endodônticos rotatórios de NiTi BioRace (BR); Protaper (PT) e Twisted File (TF) após cada uso, totalizando cinco usos, simulando as condições clínicas. Um total de 75 molares superiores humanos extraídos cuja raiz disto-vestibular apresentava curvatura de 0 a 5° e mésio-vestibular entre 20 e 30° de acordo com o método de Weine, foram selecionados e divididos em três grupos com 25 espécimes. Para o grupo I: realizou-se instrumentação com o sistema BR; para o grupo II com o sistema PT e para o grupo III, com o TF. Foram utilizadas cinco caixas de cada sistema rotatório para instrumentar os canais mesio e distovestibulares. Inicialmente os instrumentos foram fotografados em M.E.V. com aumento de 35 vezes, utilizados uma vez e em seguida passaram por um protocolo de limpeza baseado no proposto por Parashos, Linsuwanont e Messer (2004) previamente a esterilização e, em seguida eram analisados em M.E.V., antes do uso seguinte. Esses procedimentos foram realizados até o último uso. Os dados de limpeza foram submetidos ao teste estatístico de Kruskal Wallis para comparação global e ao teste de Dunn para comparação individual dos grupos, enquanto para análise da deformação foram submetidos ao teste estatístico do Qui-quadrado para comparação global e ao teste exato de Fisher para as comparações individuais, todos com significância de 5%. Os resultados apontaram diferenças estatisticamente significantes quanto à limpeza para o sistema BR com maior quantidade de detritos remanescentes do processo de fabricação em relação ao PT e TF; após os 5 usos, os sistemas BR e PT apresentavam-se mais limpos em relação ao início do experimento, enquanto o TF permaneceu com quantidade semelhante de detritos superficiais. Ocorreu deformação em 40% do sistema BR, sendo 5% fratura e, 100% do TF, sendo 40% fratura. O sistema PT não sofreu danos consideráveis de acordo com os critérios avaliados. Por meio dos resultados obtidos neste estudo, concluiu-se que o protocolo de limpeza utilizado não proporcionou superfícies completamente limpas tanto no decorrer quanto ao final do experimento e quanto a deformação superficial, o sistema TF apresentou o pior resultado, seguido do BR, enquanto o PT que não apresentou qualquer deformação quanto aos critérios avaliados. / The aim of this study was to evaluate by scanning electron microscopy (SEM) the debris removal and deformation surface by rotary NiTi endodontic systems BioRace (BR), Protaper (PT) and Twisted File (TF) before each use, total five uses, simulating clinical conditions. A total of 75 extracted human molars whose disto-vestibular roots had curvature between 0 and 5 degrees and mesio-vestibular roots had curvature between 20 and 30 degrees according to the Weine method were selected and divided into three groups of 25 specimens. In the Group I: was used the BR system, group II was used the PT system and group III was used the TF system to shaping the mesio and distovestibular molars canals. Were used a total of five boxes to each rotary system. Initially, the instruments were examined by SEM at a magnification of 35x, then used into root canals and submitted through the cleaning protocol based on proposed by Parashos, Linsuwanont and Messer (2004) prior to sterilization for further examination by SEM, before the next use. These procedures were carried out until the last use. The cleaning data were analysed using statistical Kruskal Wallis test for global comparison and the Dunn test for individual groups comparison. The deformation data were analysed using Chi-square test for overall comparison and Fisher exact test for individual comparisons, both with 5% significance. The results showed the following statistically significant differences regarding cleaning to BR system with highest amount of debris remaining from the manufacturing process in relation to the PT and TF; after the five uses, the BR and PT systems were cleaner in relation to the initial experiment, but the TF system had the same debris amount. The deformation occurred in 40% of the BR system, with 5% fractured and 100% of the TF, with 40% fractured. The PT system has not suffered considerable damage in accordance with the criteria evaluated. The results of this study showed that the protocol did not provide cleaning surfaces completely free of debris, especially in the TF system, while for the BR and PT, resulting in cleaner surfaces at the end of the experiment compared with the dirt initial (immediately removed from their packaging). The surface deformation of TF system presented the worst results, followed by the BR and PT did not show any deformation on the criteria evaluated.
5

Avaliação in vitro da capacidade de corte e deformação de limas rotatórias de níquel-titânio / In vitro evaluation of the capability of cut and deformation of rotary nickeltitanium files

Paulo Roberto Baptista Reis 05 August 2009 (has links)
Objetivo: A busca incessante de melhorar o preparo do canal radicular faz com que novos instrumentos sejam projetados. Porém, diversos fatores como ângulo de corte, secção transversal, conformação da ponta e conicidade influenciam NBA fratura desses instrumentos. Sendo assim, o propósito da presente investigação foi avaliar in vitro a capacidade de corte e deformação de lima rotatória F2 do sistema ProTaper Universal e da lima 25/06 do sistema EndoSequence, ambas de níqueltitânio em função do número de usos. Método: Para realização deste estudo foi utilizada uma amostra não aleatória por conveniência de dez limas rotatórias F2 do Sistema ProTaper Universal e dez limas rotatórias n 25/06 do Sistema EndoSequence. Resultados: Na análise estatística descritiva do somatório dos desgastes das limas ProTaper Universal, o coeficiente de variação foi de 8,7%, e para o EndoSequence foi de 9,12%. Quando comparada a eficiência de corte dos somatórios de desgastes não verificou-se diferença estatisticamente significante entre as limas ProTaper Universal e as EndoSequence.. As limas F2 ProTaper Universal analisadas demonstraram perda de corte progressiva a partir do primeiro uso com estatística significante até o quinto uso, enquanto as limas 25/0,6 EndoSequence também demonstraram perda de corte progressiva significante do primeiro ao quinto uso com exceção do quarto uso onde não houve perda de corte significante em relação ao terceiro uso. Acredita-se que em função do exposto acima, quando se comparou a perda de corte dos diferentes usos entre os dois grupos só houve diferença estatística significante na comparação entre o quarto uso na qual as limas EndoSequence demonstraram melhor desempenho que as limas ProTaper Universal, no restante da comparação não houve diferença estatística significante entre as limas estudadas. Quanto à deformação das limas estudadas verificou-se que não houve diferença estatisticamente significante quando observadas em microscópio eletrônico de varredura. Conclusões: Mediante a metodologia utilizada e com base nos resultados obtidos concluiu-se que as limas ProTaper e EndoSequence apresentaram capacidade de corte semelhantes; no que se refere à deformação das limas, verificou-se que entre estas duas marcas utilizadas não houve diferença estatisticamente significante. / Aim: The search to improve root canal preparation makes new instruments are designed. However, several factors such as cutting angle, cross section, forming the tip and taper influence the fracture of these instruments. Therefore, the purpose of this investigation was to evaluate in vitro the ability to cut and deformation of rotating file F2 ProTaper Universal system and file system EndoSequence of 25/06, both nickel-titanium based on the number of uses. Methods: For this study we used a non-random convenience sample of ten files rotary F2 ProTaper Universal System and ten rotary files number 25/06 of System EndoSequence. Results: In the descriptive statistical analysis of the sum of the loss of files ProTaper Universal, the coefficient of variation was 8,7%, and the EndoSequence was 9,12%. When compared to the cutting efficiency of summation of damage there was no statistically significant difference between the files ProTaper Universal and EndoSequence. The F2 ProTaper Universal files examined showed progressive loss of cut from the first use with statistically significant until the fifth use, while the 25/06 EndoSequence files also demonstrated significant progressive loss of cutting from the first to the fifth use except the forth use, where there was no loss of significant cuts in relation to the third use. It is believed that based on the last sentence, when were compared the loss of cutting of different uses between both groups, there was only one statistically significant difference in the comparison between the forth uses, where the used EndoSequence files shows better performance than the ProTaper Universal files, and the rest of the comparison was not statistically significant between the files studied. As the deformation of the files examined it was found that there was no statistically significant when seen in the scanning electron microscope. Conclusions: Using the methodology used and based on the results obtained it was concluded that the ProTaper files and EndoSequence showed similar ability to cut, in relation to deformation of files, found that between these two marks used no difference statistically significant.