Representação de partes parcialmente observaveis de sistemas de energia eletricaPizzolante, Antonio Chaves 15 July 2018 (has links)
Orientador : Alcir Jose Monticelli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-15T13:58:30Z (GMT). No. of bitstreams: 1
Pizzolante_AntonioChaves_M.pdf: 2662549 bytes, checksum: 9a34ddc036740644a2751d1646936c37 (MD5)
Previous issue date: 1979 / Resumo: Neste trabalho são estudados modelos para representar partes parcialmente observáveis de sistemas de energia elétrica. Utilizaram-se dois tipos de métodos: equivalentes externos do tipo WARD e modelos de fluxo de carga equivalente. Foi dada ênfase a modelos para utilização em execução de funções de controle em tempo real, mas pode-se também usá-los em estudos "off-line". Os modelos apresentados foram testados na análise de contingências de quatro sistemas de teste dois dos quais representam o sistema interligado da região sudeste do Brasil / Abstract: Not informed / Mestrado / Mestre em Engenharia Elétrica
|
12 |
Equivalente estatico reduzido : uma revisão critica do modelo Ward EstendidoTavares, Paulo Cezar Coelho 16 July 2018 (has links)
Orientador : Sigmar M. Deckmann / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-16T19:06:48Z (GMT). No. of bitstreams: 1
Tavares_PauloCezarCoelho_M.pdf: 4775733 bytes, checksum: 19815d95e62b6ce9d54b347e67eff4ef (MD5)
Previous issue date: 1987 / Resumo: O trabalho se propõe a fazer uma revisão da metodologia descrita na literatura para a obtenção do equivalente
estático Ward Estendido. Particular atenção foi dedicada à metodologia das reaçoes das barras externas de tensão controlada, das ligações reativas "shunt" e das cargas não-lineares, visando à análise de segurança estática em sistemas parcialmente observáveis. Através de exemplos simples buscou-se estabelecer relações causa-efeito para estudar esses problemas de modelagem. Através desses exemplos foi possível mostrar que tanto as barras de tensão controlada (tipo
PV) quanto as ligações reativas "shunt" externas podem ser representadas através de um equivalente reativo exato. Constatou-se ainda que as principais fontes de erros dos equivalentes tipo Ward são provenientes da modelagem de cargas e gerações como sendo injeções de potência constante (ativa e reativa). A criação de ligações "só P" isto é, que não existem do ponto de vista reativo, permite uma representação mais precisa dos caminhos externos efetivamente disponíveis para o fluxo de potência ativa e reativa na presença de barras intermediárias de tensão controlada. Do ponto de vista computacional foi desenvolvido um algoritmo para a obtenção, num único processo de redução, tanto do equivalente série como do equivalente "shunt", levando em conta o efeito das barras PV eliminadas. Com isso o tempo necessário para a atualização do equivalente foi reduzido de aproximadamente 50%, conforme mostram os exemplos testados / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
|
13 |
Equivalentes externos tipo Ward visando estudos de otimização em sistemas de potenciaNepomuceno, Leonardo 21 June 1993 (has links)
Orientadores: Anesio dos Santos Junior, Geraldo R. Martins da Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-18T09:07:16Z (GMT). No. of bitstreams: 1
Nepomuceno_Leonardo_M.pdf: 4742662 bytes, checksum: c774990357c04c6278c43e17292c615a (MD5)
Previous issue date: 1993 / Resumo: A execução de funções avançadas em centros de controle tais como análise de contingências, despacho de reativos, etc, necessitam modelos adequados de representação das partes não observáveis (sistema externo). Os equivalentes externos clássicos foram desenvolvidos visando basicamente a análise de contingências. Destaca-se o desempenho do equivalente WARD ESTENDIDO (W.E.) que hoje representa o estado da arte para os modelos baseados em redução de circuitos. Neste trabalho busca-se avaliar o desempenho do equivalente W.E. em resposta a alterações ocorridas em estudos de otimização. Além disso, é feita a proposta de um modelo, denominado WARD REATIVO INTERNO (WRINT), resultante de uma adaptação no W.E. visando uma melhoria de desempenho frente a alterações ocorridas nos estudos de otimização. A idéia geral desse modelo é refletir para dentro do sistema interno a capacidade de resposta reativa do equivalente W.E. São apresentados resultados comparativos de testes computacionais e detalhes de implementação das rotinas utilizadas / Abstract: The execution of functions such as contingency analysis, optimization, reactive dispatch, etc, at the control centers requires appropriate models representing the nonobservable parts (external sistem). The classical external equivalents have been deveIopped considering basically the contingency analysis. This work points out the performance of the EXTENDED WARD EQUIVALENT (W.E.), which currently represents the state of art concerning reduced circuit based models. The work analyzes the W.E. response to changes occurred in optimization studies. Moreover, a new model, named INTERNAL REACTIVE WARD (WRINT), resulting from an adaptation of the W.E. is proposed focussing on the improvement of the equivalent in case of changes occurred in optimization studies. The model's general idea is to reflect the equivalent's capacity of reactive response into the internal system. Comparative computational test resuIts are shown. The details of routines implementation are also pointed out / Mestrado / Mestre em Engenharia Elétrica
|
14 |
Analise de segurança estatica de sistemas de potencia : um estudo sobre criterios de seleção de contingencias no subproblema reativoSantos, Jose Vicente Canto dos 16 December 1993 (has links)
Orientador: Ariovaldo V. Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-19T05:20:07Z (GMT). No. of bitstreams: 1
Santos_JoseVicenteCantodos_M.pdf: 5427056 bytes, checksum: f141861bf3f4bd8a080be72b1525c898 (MD5)
Previous issue date: 1993 / Resumo: O principal objetivo da análise de segurança estática em sistemas de potência é a determinação do nível de gravidade das diferentes contingências que podem ocorrer em um sistema. Habitualmente, a análise de segurança estática é dividida em duas partes: seleção e análise de contingências. Neste trabalho, são estudados diversos critérios de seleção de contingências aplicáveis ao subproblema reativo e são apresentadas comparações entre os resultados fornecidos por diferentes critérios. Também são estudadas várias formas de avaliação do impacto causado por contingências sobre o perfil reativo de sistemas de potência / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
|
15 |
Estimação estatica de estado em sistemas de energia eletrica utilizando fatoração ortogonal QRCorrea, Silvino Soares 18 August 1994 (has links)
Orientador: Basilio E. A. Milani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-19T13:53:59Z (GMT). No. of bitstreams: 1
Correa_SilvinoSoares_M.pdf: 2641756 bytes, checksum: da3dd6302ec77b280ef883471e188e11 (MD5)
Previous issue date: 1994 / Resumo: Este trabalho trata de aspectos computacionais do problema de estimação estática de estado e processamento de erros grosseiros, em sistemas de energia elétrica, utilizando a técnica de mínimos quadrados ponderados não linear.
São apresentados e analisados, sumariamente, os métodos do tipo Newton modificado para solução do problema de mínimos quadrados não linear. Para solução da seqüência de problemas de mínimos quadrados lineares gerada pelo
método de Newton modificado, são apresentados e analisados os métodos de equações normais, equações normais híbrido e fator ação ortogonal QR. Para obtenção da fator ação QR nos métodos das equações normais híbrido e fatoração ortogonal QR, são apresentados e discutidos algoritmos utilizando rotações de Givens. São apresentados resultados comparativos da precisão esperada dos algoritmos analisados juntamente com estimativas do esforço computacional requerido - FLOPS. Para processamento de erros grosseiros são apresentados e analisados algoritmos para detecção de erros utilizando
teste de qui-quadrado, identificação de erro utilizando resíduos normalizados e eliminação de erros fazendo a atualização das matrizes das equações normais e fator ação QR. São propostos algoritmos, compatíveis com os métodos das
equações normais híbrido e fator ação ortogonal QR, para cálculo dos resíduos normalizados utilizando a matriz R e atualização dos fatores QR utilizando rotações de Givens convencionais / Abstract: This work is concerned with computational aspects of the problem of static state estimation and bad data processing, in electrical power systems, using the nonlinear weighted least-squares technique. Modified Newton type
methods, for solution of the nonlinear least-squares problem, are briefly presented and analysed. For solution of the sequence of linear least-squares problems, produced by modified Newton methods, the methods normal equations, hybrid normal equations and orthogonal QR factorization are presented and analysed. AIgorithms using Givens rotations, for computation
of QR factors in the methods hybrid normal equations and orthogonal QR factorization are presented and discussed. Comparative results are presented concerning the expected precision of the analysed algorithms together with estimates of their required computational effort - FLOPS. For bad data processing, and analysed some algorithms for error detection using chi-square test, error identification using normalized residues and error elimination by updating the pertinent matrices of the normal equations and QR factorization are presented. AIgorithms, compatible with the methods hybrid normal equations and orthogonal QR factorization, for computation of normalized residues using the R matrix and for updating QR factors using conventional Givens rotations are proposed. / Mestrado / Telecomunicações e Telemática / Mestre em Engenharia Elétrica
|
16 |
Um modelo de pre-despacho com margem de estabilidade de tensãoMoreira, Frederico Silva 28 July 2018 (has links)
Orientador : Takaaki Ohishi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-28T01:57:19Z (GMT). No. of bitstreams: 1
Moreira_FredericoSilva_M.pdf: 516593 bytes, checksum: fd85a5d12855f42f0bfe47a3310a7df9 (MD5)
Previous issue date: 2001 / Mestrado
|
17 |
Estudo da estabilidade de sistemas eletricos atraves do controle do fluxo de potencia ativa realizado pela maquina de induçãoSalerno, Carlos Henrique 15 December 1992 (has links)
Orientadores: Mauro Sergio Miskulin, Luciano Martins Neto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-17T11:09:11Z (GMT). No. of bitstreams: 1
Salerno_CarlosHenrique_D.pdf: 11433134 bytes, checksum: ea1b8a045222637356e4228f5027a233 (MD5)
Previous issue date: 1992 / Resumo: O emprego de pequenas máquinas de indução em determinados pontos estratégicos de um sistema elétrico, pode representar uma melhor ia na estabilidade do referido sistema. Assim este trabalho trata da implementação de um modelo dinâmico da máquina de indução com seu regulador de velocidade em um programa de estabilidade. Através de simulações computacionais pode-se fazer uma análise da estabilidade transitória de um sistema elétrico observando-se os efeitos da máquina de indução no sistema fazendo a regularização do fluxo de potência ativa diferentemente do método tradicional que trata da regularização da potência reativa. São também realizados ensaios em laboratório com os mesmos objetivos. Uma análise de parâmetros é feita com intuito de observar seus efeitos na máquina de indução durante as simulações. Os resultados obtidos nas simulações bem como nos testes laboratoriais comprovam a idéia apresentada / Abstract: The improvement of the stability of a large power systems can be obtained through small induction generators, which are employed in strategic points of the system. In this work, to illustrate this fact, a power system stability program is used, in which is incl uded a dynamic model for induction generator with speed governor and also experimental tests are made. The following operation condition of the power system is analysed. Assuming that one of these induction generators is on a certain busbar of the power system, a system disturbance occurs in such a way to require a transient increase of active power. Due to of the intrinsic characteristics of any induction machine, and particularly in this case, the reduced size of the induction generator employed, this machine will take the lead regarding to the synchronous generators and it will supply part of the active power demanded. since this fact represents a relief for the synchronous generation, an improvement of the system stability is obtained. For this operational condition theoric and experimental results are shown. The analysis of this results confirm the effectiveness of the idea here presented. / Doutorado / Doutor em Engenharia Elétrica
|
18 |
Análise de eventos em sistemas elétricos de potência em tempo real utilizando sincrofasores e a transformada wavelet discretaArruda, Eduardo Henrique Zanella de January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2017. / Made available in DSpace on 2018-02-06T03:17:36Z (GMT). No. of bitstreams: 1
349769.pdf: 7351711 bytes, checksum: c4c9058ce4e9650224b4d6d367c6376e (MD5)
Previous issue date: 2017 / Este trabalho tem como objetivo o estudo e o desenvolvimento de metodologias para a análise automática de eventos, em tempo real, em Sistemas de Energia Elétrica (SEE), com a utilização de dados de medição sincronizada de fasores (SMSF) e da Transformada Wavelet Discreta (TWD). As metodologias aplicadas empregam conceitos dos sistemas de monitoramento de grandes áreas (WAMS). Tais sistemas visam melhorar e facilitar a operação em tempo real de grandes SEEs, os quais reduzem o tempo para a tomada de decisões a fim de evitar a propagação de eventos por meio do efeito cascata, diminuindo, assim, a ocorrência de blecautes. A análise automática de eventos engloba a detecção em tempo real, a classificação quanto ao tipo de evento, sua localização e a magnitude em MW, quando há cortes de carga ou geração. Todas as etapas do processo de análise de eventos fazem o uso da TWD, por meio de uma análise multiresolução (AMR). Essa técnica de análise de sinais se destaca pela capacidade de decompor o sinal em funções no domínio do tempo e da frequência, simultaneamente, os quais permitem identificar as frequências existentes no sinal em seu respectivo instante temporal. As características dos sinais são observadas em tempo real e, na ocorrência de um evento, as características do evento, por sua vez, são extraídas em diferentes resoluções e interpretadas pelo algoritmo desenvolvido. O algoritmo foi
implementado em linguagem C# e validado com dados do Sistema Nacional de Medição Sincronizada de Fasores em Baixa Tensão (110 ou 220 V) - SMSF MedFasee BT/UFSC. Este sistema dispõe de 25 pontos
de medição instalados em universidades, abrangendo 20 estados das cinco regiões geográficas do país. Os resultados obtidos demonstram que a TWD apresenta resultados efetivos em todas as etapas do processo de análise automática de eventos em SEE em tempo real. / Abstract : This work has as objective the study and the development of methodologies for the automatic analysis of events in real-time, in Electric Power Systems (EPS), with the use of synchronized phasor measurement data and the Discrete Wavelet Transform (DWT). The methodologies use the concept of wide area measurement systems (WAMS). Such systems aim to improve and facilitate the real-time operation of large EPS, reducing the time for actions to be taken, in order to prevent the propagation of an event through the cascading effect, thereby decreasing blackout occurrences. Automatic event analysis encompasses real-time detection, classification of type of event, its location and its magnitude, in MW, when there are load or generation shedding. All stages of the process of event analysis make use of TWD through a Multiresolution Analysis (AMR). This signal analysis technique is highlighted by the capacity to decompose the signal into functions in time and frequency domains simultaneously, which allows identifying the existing frequencies of the signal at their respective time instant. The signal characteristics are observed in real-time and, with the occurrence of an event, the event characteristics are extracted at different resolutions and interpreted by the developed algorithm. The algorithm was developed in C# language and validated with data from the National Synchronized Measurement System at Low Voltage (110 or 220 V) - SMSF MedFasee BT. This system has 25 measuring points installed at universities, covering 20 states of the five geographic regions of Brazil. The acquired results show that DWT presents effective results in all stages of the processes of automatic event analysis in real-time, in EPS.
|
19 |
Desenvolvimento de um laboratório virtual para capacitação tecnológica a distância em proteção de sistemas elétricos / Development of a virtual laboratory for distance training in protection of electrical systemsSilva, Carlos Henrique de Castro January 2011 (has links)
SILVA, C. H. C. Desenvolvimento de um laboratório virtual para capacitação tecnológica a distância em proteção de sistemas elétricos. 2011. 89 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2014-01-02T13:44:37Z
No. of bitstreams: 1
2011_dis_chcsilva.pdf: 3252671 bytes, checksum: 1e0a922bd4f757b2cc84b884b484021c (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2014-01-07T18:28:07Z (GMT) No. of bitstreams: 1
2011_dis_chcsilva.pdf: 3252671 bytes, checksum: 1e0a922bd4f757b2cc84b884b484021c (MD5) / Made available in DSpace on 2014-01-07T18:28:07Z (GMT). No. of bitstreams: 1
2011_dis_chcsilva.pdf: 3252671 bytes, checksum: 1e0a922bd4f757b2cc84b884b484021c (MD5)
Previous issue date: 2011 / As the demand for electrical energy increases and requirements from regulatory agencies for improved reliability, security and efficiency on the operation of electric power systems, the need for professionals ever more qualified on planning and operation power systems also increases. However, with the need for continued technical update and as a result of rationalization policies of costs and provision of personnel for training, the distance learning techniques have evolved and reached different areas of knowledge. This work presents a Simulator for Presence and Distance Learning about Operation and Protection of Electric Systems (STOP). The STOP Simulator is developed in Java, which enables it to be used in the following systems: Unix, Linux, Windows, MacOS. The STOP can be applied in class as well as distance training and is directed to the training of engineering students, technicians and professionals specialized on electric power systems. The STOP is integrated to a Learning Virtual Environment (AVA), the Moodle. The integration enhances the teaching-learning process making it more effective by using a tool able to simulate real life situations. Simulators in virtual environments are an alternative to reducing costs in companies and educational institutions. The STOP is a software tool featuring one-line diagrams with the main components of the protection system, short-circuits simulation and reconfiguration of the system by setting relays for coordination of the system protection and redefinition of parameters. / Com o aumento na demanda de energia elétrica e a exigência de maior confiabilidade, segurança e eficiência na operação de sistemas elétricos de potência por parte dos órgãos reguladores, aumentou a necessidade por profissionais cada vez mais qualificados em planejamento e operação dos sistemas de potência. No entanto, com a necessidade de atualização técnica continuada e em decorrência da política de racionalização de custos e de disponibilização de pessoal, as técnicas de ensino a distância têm evoluído e alcançado abrangência nas mais diferentes áreas do conhecimento. Este trabalho apresenta um Simulador para Treinamento Presencial e a Distância em Operação e Proteção de Sistemas Elétricos (STOP). O simulador STOP é desenvolvido em Java, podendo ser utilizado em ambientes: Unix, Linux, Windows, MacOS. O STOP pode ser aplicado em treinamento presencial e a distância e está voltado à capacitação de estudantes de engenharia, técnicos e profissionais da área de sistemas elétricos de potência. O STOP está integrado a um Ambiente Virtual de Aprendizagem (AVA), o Moodle. A integração enriquece o ensino-aprendizado tornando-o mais efetivo com o uso de uma ferramenta capaz de simular situações reais. Os simuladores em ambientes virtuais são alternativas para a redução de custos em empresas e instituições de ensino. O simulador STOP é um software composto de diagramas unifilares, com a representação dos principais componentes do sistema de proteção, tornando possível ao usuário simular faltas e reconfigurar o sistema elétrico, por meio de ajustes de relés para coordenação da proteção e redefinição de parâmetros.
|
20 |
Investigação de metodologias de validação de modelos de simulação da dinâmica de sistemas elétricos utilizando sincrofasoresSilva, Paulo André Sehn da January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Elétrica, Florianópolis, 2014. / Made available in DSpace on 2015-04-29T21:08:38Z (GMT). No. of bitstreams: 1
333105.pdf: 3459954 bytes, checksum: f674912cfaf25f34b994218a7c01279b (MD5)
Previous issue date: 2014 / Nesta dissertação apresentam-se os resultados da investigação de metodologias para a validação de modelos de simulação da dinâmica de sistemas elétricos de potência utilizando dados fasoriais sincronizados. Com a finalidade de quantificar as diferenças entre registros do sistema e a resposta de simulações, bem como localizar áreas com modelos imprecisos, são propostas quatro estratégias de análise. Na primeira, as discrepâncias são analisadas no domínio do tempo, propondo indicadores quantitativos para o diagnóstico e a localização de modelos imprecisos no sistema. De maneira semelhante, o segundo método quantifica as diferenças entre simulação e registro no domínio da frequência, aplicando a Transformada Discreta de Fourier em ambos os sinais. No terceiro método, são verificadas as discrepâncias em modos de oscilação, sendo considerados a frequência de oscilação, a taxa de amortecimento e os fatores de participação. O quarto método baseia-se na sensibilidade de trajetórias, em que o efeito da mudança de parâmetros é identificado nas medidas do sistema. Para validar as metodologias propostas, experimentos computacionais foram realizados empregando dados de um sistema de pequeno porte e do SIN ? Sistema Interligado Nacional. Os resultados demonstraram a efetividade das metodologias propostas, tanto na quantificação de discrepâncias, quanto na identificação de áreas do sistema com imprecisão nos modelos de simulação.<br> / Abstract : In this dissertation the results for several methodologies for system wide model validation using synchronized phasor data are presented. Four methods for diagnosing the existence of errors in simulation models are proposed. These strategies are meant to quantify discrepancies between the simulation results and the system records and identify the source of errors in simulation models. In the first approach, discrepancies are measured in the time domain to identify areas with models misrepresented. In the second method, the differences between simulation and measurements are determined in the frequency domain by applying the Discrete Fourier Transform in both signals. In the third method, discrepancies in the oscillation modes are attributed to errors in the system components models listed in the participation factors associated with that mode. The fourth method is based on the sensitivity trajectory, where the effect of changing parameters is identified in the measurements of system. Results obtained by simulation confirm the applicability of the proposed methods for the identification of areas containing models errors.
|