Response of a slotted plate flow meter to horizontal two phase flow

Muralidharan, Vasanth 17 February 2005 (has links)
The slotted plate flow meter has been widely tested as an obstruction flow meter during the past several years. It has been tested for both single-phase flows as well as for two-phase flows. Previous studies have revealed that the slotted plate flow meter is always better in performance and accuracy than the standard orifice plate flow meter. This study is primarily based on how a slotted plate responds to horizontal two-phase flow with air and water being used as the working fluids. The plates under consideration are those with beta ratios of 0.43 and 0.467. Experiments have been performed with six different configurations of the slotted plate test sections. The performances of the slotted plate flow meters will be compared to that of a standard orifice plate flow meter and then with a venturi. The effects of varying the upstream quality of the two-phase flow on the differential pressure and the coefficient of discharge of the slotted plates, the standard orifice plate and the venturi will be evaluated. Response characteristics at low differential pressures will be investigated. Tests for repeatability will be performed by studying the effects of the gas Reynolds number and the upstream quality on the differential pressure. The differential pressures across the slotted plates, the standard orifice plate and the venturi will be compared. Reproducibility will be evaluated by comparing the data obtained from all six different configurations. One of the main objectives of this study is to arrive at the best suitable procedure for accurately measuring the flow rate of two-phase flow using the slotted plate flow meter.
2

Response of a slotted plate flow meter to horizontal two phase flow

Muralidharan, Vasanth 17 February 2005 (has links)
The slotted plate flow meter has been widely tested as an obstruction flow meter during the past several years. It has been tested for both single-phase flows as well as for two-phase flows. Previous studies have revealed that the slotted plate flow meter is always better in performance and accuracy than the standard orifice plate flow meter. This study is primarily based on how a slotted plate responds to horizontal two-phase flow with air and water being used as the working fluids. The plates under consideration are those with beta ratios of 0.43 and 0.467. Experiments have been performed with six different configurations of the slotted plate test sections. The performances of the slotted plate flow meters will be compared to that of a standard orifice plate flow meter and then with a venturi. The effects of varying the upstream quality of the two-phase flow on the differential pressure and the coefficient of discharge of the slotted plates, the standard orifice plate and the venturi will be evaluated. Response characteristics at low differential pressures will be investigated. Tests for repeatability will be performed by studying the effects of the gas Reynolds number and the upstream quality on the differential pressure. The differential pressures across the slotted plates, the standard orifice plate and the venturi will be compared. Reproducibility will be evaluated by comparing the data obtained from all six different configurations. One of the main objectives of this study is to arrive at the best suitable procedure for accurately measuring the flow rate of two-phase flow using the slotted plate flow meter.