• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização preliminar do subsolo da área urbana de Boa Vista-RR, a partir de sondagens de simples reconhecimento

Iana Carmem de Souza e Silva Avila 03 December 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O trabalho foi desenvolvido na área urbana de Boa Vista, as variáveis estudadas foram: altitude, nível da água e limite de sondagem objetivando a caracterização preliminar do subsolo de Boa Vista, através de sondagens de simples reconhecimento. Foram utilizados 75 pontos dos quais 47 do banco de dados da empresa A.P. Engenharia e RC engenharia nos anos de 1994 à 2007 e mais 28 dados levantados durante a pesquisa. Foi realizado a análise multivariada para o conhecimento de padrões não supervisionados as técnicas de Análise de Componentes Hierárquicos confirmados pela Análise de Componentes Principais. Com isto foram identificadas 3 Zonas para a Cidade de Boa Vista: Menos Vulneráveis; Zona 1 - englobando somente o bairro Cidade Satélite e Zona 3 - os bairros Aquilino da Mota Duarte, bairro Centro e seu transecto até o bairro Caçari, bairro Caçari e bairro Paraviana.; Mais vulneráveis: Zona 2 - todos os bairros localizados após o limite da BR 174, sentido leste, com exceção do Bairro Aquilino da Mota Duarte e os bairro entre a BR 174, Centro, Caçari e Paraviana. A média do Nível de água (NA) da cidade foi de 6,3m, os bairros com maior curva de nível se enquadraram nos bairros de menos vulnerabilidade; nos pontos Cecília Brasil, Cel Mota, Ig Mirandinha, Av Gen Sampaio registraram NA na superfície; o solo mais resistente foi o ponto Centro SEFAZ, no bairro Centro com limite de sondagem de 1,1m, o solo com menor resistência foi o ponto BR 174 localizado em área de cerrado após a ponte do Cauamé. Após a determinação das zonas menos e mais vulneráveis foi realizada uma análise de granulometria para representar cada zona, que classificou o material do ponto mais vulnerável como areia franca e franco arenoso e para o ponto representante da zona menos vulnerável apresentou a classificação do material como franco argilo arenoso e franco arenoso / Considering all the urban construction of Boa Vista, the following variables had been studied: altitude, water level and limit of probing, objectify the preliminary characterization of the subsoil of Boa Vista through probing of simple recognition. Had been used 75 point whose 47 were from the data base of the company A.P Engineering and RC engineering in the year of 1994 to the 2007 and more 28 data raise during the research. Was accomplished the analysis of multivary for the knowledge of standard not supervised according to the technique of Analysis of Hierarchic Component confirm by the Analysis of the Major result. With this 3 Zones for the City of Boa Vista had been identified: Less Vulnerable; Zone 1 - only englobando the Cidade Satelite districts and Zone 3 - the Aquilino da Mota Duarte districts, Centro districts and its transecto until the Caçari districts , Caçari districts and Paraviana districts; More vulnerable: Zone 2 - all the districts located after the limit of BR 174, felt east, with exception of the Aquiline districts of the Mota Duarte and the districts between BR 174, Center, Caçari and Paraviana. The average of the water Level (In) of the city was of 6,3m, the districts with bigger curve of level if they had fit in the districts of little vulnerability; in the points Cecília Brasil, Cel Mota, Ig Mirandinha, Av Gen Sampaio they had registered In the one in the surface; the ground most resistant was the point Center SEFAZ, in the Center districts with limit of sounding of 1,1m, the ground with lesser resistance was located point BR 174 in area of after closed the bridge of the Cauamé. After the determination of the zones and less vulnerable was carried through a granulometria analysis to represent each zone, that classified the material of the point more vulnerable as frank sand and frank arenaceous and for the representative point of the zone less vulnerable it presented the classification of the material as frank argilo arenaceous and frank arenaceous
2

Avaliação no campo de um TDR segmentado para determinação da umidade do solo. / Field evaluation of TDR multilevel probe for soil water content measurement.

Cichota, Rogerio 11 April 2003 (has links)
Das várias proposições para a determinação da umidade do solo, a técnica da reflectometria no domínio do tempo (TDR) vem despertando bastante interesse, pois apresenta características desejáveis, como a mensuração em tempo real e a possibilidade de leituras automatizadas. Por outro lado, além do custo elevado dos equipamentos, este método ainda apresenta necessidade de calibração. O desempenho no campo também carece ser mais bem estudado. Com o objetivo de avaliar a performance de um equipamento de TDR com sondas segmentadas em condições de campo, utilizando como método de referência a tensiometria, foram conduzidos experimentos em dois períodos de anos consecutivos, com a coleta de valores da umidade do solo e da respectiva leitura do TDR, em 48 baterias compostas de uma haste de TDR de cinco segmentos e um tensiômetro para cada segmento, dispostas em uma transeção em um Latossolo Vermelho-amarelo no campus da ESALQ/USP em Piracicaba/SP. Embora trabalhosa, a tensiometria mostrou-se suficiente como método de referência para a umidade no campo, pois sua metodologia é bem estabelecida e seu funcionamento não influencia nem é influenciado pelo TDR. As umidades observadas, obtidas a partir do potencial matricial e das curvas de retenção, mostraram padrão de variação semelhante entre os dois períodos, ao contrário das leituras do TDR, que exibiram médias e amplitudes pouco correspondentes entre os pontos num período e noutro. A correlação entre a umidade e a leitura do TDR foi em geral bastante reduzida e quanto mais restrito o conjunto analisado, como por haste ou segmentos, melhores resultados foram obtidos. As curvas de calibração mostraram grande variabilidade entre segmentos, tanto para o coeficiente de determinação como para o padrão da resposta, expresso pelo coeficiente angular das retas. Ajustes efetuados com os dados agrupados por haste ou por camada exibiram aumento da dispersão e forte diminuição do coeficiente de determinação. As retas de calibração também exibiram padrões diferenciados entre os períodos e ajustes com os dados dos dois conjuntos mostraram-se em geral ruins. Não foi possível identificar nenhum padrão para as variações da calibração ao longo da transeção, para algumas camadas houve indícios de dependência espacial, mas nenhuma relação definida com os atributos físicos determinados foi encontrada. Os resultados deste trabalho vêm complementar outros estudos reportados na literatura, mostrando que a aplicabilidade deste modelo de TDR segmentado é praticamente inviável, pois as variações da resposta do TDR são muito grandes entre as várias hastes ou mesmo entre segmentos de uma mesma haste, ou ainda entre os dois períodos. O trabalho também mostra a importância de estudos no campo para a validação de novos métodos ou equipamentos de determinação da umidade do solo. / Among many methods to assess soil water content, time domain reflectometry (TDR) is of recent interest due to its many desirable features as real-time method allowing automation. On the other hand, the equipment is expensive and needs calibration. More studies about its field performance are also required. With the objective of evaluating a TDR device with multilevel probes at field conditions, using tensiometry as reference method for soil water content, two experiments were conducted in consecutives years, by collecting values of soil water content and the respective TDR response in 48 batteries, that were made up of a TDR probe with 5 segments and a tensiometer for each segment, installed in a Red-yellow Oxisol (Hapludox) at the ESALQ/USP campus in Piracicaba/SP - Brasil. Although laborious, tensiometry showed to be a good reference to assess soil water content, because its methodology is well established and its functioning does not influence nor is influenced by the TDR. Soil water content obtained by matric potential and retention curves showed similar patterns in both periods, contrasting with TDR response that did not exhibit correspondence for average or range of measures between periods. The correlation between soil water content and TDR response was in general very small, and smaller data sets, per probes or per segment, showed better correlations. The calibration curves showed much variability among segments, both for the determination indexes and the response pattern. Data fitting per probe or level showed increased dispersion and strong reduction for determination indexes. Calibration also showed different patterns between periods and fitting with data from both periods were in general bad. It was not possible to identify tendencies for variations of calibration along the transect, nor correlation with offer soil attributes. These results complement other studies reported in the literature, showing that this type of probe is hard to be used, due the high variations among probes or even among segments of one probe, besides of variations in time. The importance of field studies for validation of new methods or devices for soil water content measurements are also presented.
3

Avaliação no campo de um TDR segmentado para determinação da umidade do solo. / Field evaluation of TDR multilevel probe for soil water content measurement.

Rogerio Cichota 11 April 2003 (has links)
Das várias proposições para a determinação da umidade do solo, a técnica da reflectometria no domínio do tempo (TDR) vem despertando bastante interesse, pois apresenta características desejáveis, como a mensuração em tempo real e a possibilidade de leituras automatizadas. Por outro lado, além do custo elevado dos equipamentos, este método ainda apresenta necessidade de calibração. O desempenho no campo também carece ser mais bem estudado. Com o objetivo de avaliar a performance de um equipamento de TDR com sondas segmentadas em condições de campo, utilizando como método de referência a tensiometria, foram conduzidos experimentos em dois períodos de anos consecutivos, com a coleta de valores da umidade do solo e da respectiva leitura do TDR, em 48 baterias compostas de uma haste de TDR de cinco segmentos e um tensiômetro para cada segmento, dispostas em uma transeção em um Latossolo Vermelho-amarelo no campus da ESALQ/USP em Piracicaba/SP. Embora trabalhosa, a tensiometria mostrou-se suficiente como método de referência para a umidade no campo, pois sua metodologia é bem estabelecida e seu funcionamento não influencia nem é influenciado pelo TDR. As umidades observadas, obtidas a partir do potencial matricial e das curvas de retenção, mostraram padrão de variação semelhante entre os dois períodos, ao contrário das leituras do TDR, que exibiram médias e amplitudes pouco correspondentes entre os pontos num período e noutro. A correlação entre a umidade e a leitura do TDR foi em geral bastante reduzida e quanto mais restrito o conjunto analisado, como por haste ou segmentos, melhores resultados foram obtidos. As curvas de calibração mostraram grande variabilidade entre segmentos, tanto para o coeficiente de determinação como para o padrão da resposta, expresso pelo coeficiente angular das retas. Ajustes efetuados com os dados agrupados por haste ou por camada exibiram aumento da dispersão e forte diminuição do coeficiente de determinação. As retas de calibração também exibiram padrões diferenciados entre os períodos e ajustes com os dados dos dois conjuntos mostraram-se em geral ruins. Não foi possível identificar nenhum padrão para as variações da calibração ao longo da transeção, para algumas camadas houve indícios de dependência espacial, mas nenhuma relação definida com os atributos físicos determinados foi encontrada. Os resultados deste trabalho vêm complementar outros estudos reportados na literatura, mostrando que a aplicabilidade deste modelo de TDR segmentado é praticamente inviável, pois as variações da resposta do TDR são muito grandes entre as várias hastes ou mesmo entre segmentos de uma mesma haste, ou ainda entre os dois períodos. O trabalho também mostra a importância de estudos no campo para a validação de novos métodos ou equipamentos de determinação da umidade do solo. / Among many methods to assess soil water content, time domain reflectometry (TDR) is of recent interest due to its many desirable features as real-time method allowing automation. On the other hand, the equipment is expensive and needs calibration. More studies about its field performance are also required. With the objective of evaluating a TDR device with multilevel probes at field conditions, using tensiometry as reference method for soil water content, two experiments were conducted in consecutives years, by collecting values of soil water content and the respective TDR response in 48 batteries, that were made up of a TDR probe with 5 segments and a tensiometer for each segment, installed in a Red-yellow Oxisol (Hapludox) at the ESALQ/USP campus in Piracicaba/SP - Brasil. Although laborious, tensiometry showed to be a good reference to assess soil water content, because its methodology is well established and its functioning does not influence nor is influenced by the TDR. Soil water content obtained by matric potential and retention curves showed similar patterns in both periods, contrasting with TDR response that did not exhibit correspondence for average or range of measures between periods. The correlation between soil water content and TDR response was in general very small, and smaller data sets, per probes or per segment, showed better correlations. The calibration curves showed much variability among segments, both for the determination indexes and the response pattern. Data fitting per probe or level showed increased dispersion and strong reduction for determination indexes. Calibration also showed different patterns between periods and fitting with data from both periods were in general bad. It was not possible to identify tendencies for variations of calibration along the transect, nor correlation with offer soil attributes. These results complement other studies reported in the literature, showing that this type of probe is hard to be used, due the high variations among probes or even among segments of one probe, besides of variations in time. The importance of field studies for validation of new methods or devices for soil water content measurements are also presented.

Page generated in 0.0836 seconds