• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do desempenho de flotação por ar dissolvido no tratamento de efluente de refinaria de óleo de soja / Valuation of performance of dissolved air flotation on treatment of wastewaters of soybean oil refining

Cecchet, Juliana 06 July 2007 (has links)
Made available in DSpace on 2017-05-12T14:47:16Z (GMT). No. of bitstreams: 1 Juliana Cecchet.pdf: 2090330 bytes, checksum: 58b3febaf50310456ede4d0b8648a7f0 (MD5) Previous issue date: 2007-07-06 / The aim of this work was to value the performance of three types of coagulants, two of them of polichlorate of alum class and one of them was organic, combined to three polyelectrolytes class (anionic, cationic and no ionic) applying the dissolved air flotation (DAF), to viability their use on treatment of effluents of soybean oil refinery. The study was conducted on laboratory scale where first was tested the coagulants on several dosages combined to several bands of pH and three ascension velocities (Va), finding a optimum band of this combination for one of each three batteries. For this, was fixed parameters how time and fast mixed gradient (1 min / 150 s-1), time and slow mixed gradient (10 min / 40 s-1 5 min / 20 s-1), pressure on saturation chamber (450 kPa) and recirculation ratio (30%). Finding the optimum concentration of coagulant (Cc ótima), optimum coagulation pH (pHcoag ótimo) and optimum ascension velocities (Vaótima), fix those parameters and then goes for a variation of polyelectrolyte, testing several dosages and finding a optimum concentrate of polyelectrolyte (Cf ótimo). Finally, with junction of all optimized parameters, was varied de recirculation rate (R) (10, 20 e 30%), choosing the best R and collecting samples for the determination of levels of turbidity, total suspended solids (TSS), volatile suspended solids (VSS), oil and greases (O&G) and chemical oxygen demand (COD) remaining on treated effluent presenting a percentage of remotion COD of 95,4%, 93,7% and 95,1% and O&G of 100%, 94,2% e 99,8% for the batteries 1, 2 e 3 respectively. Despite of being excellent efficiencies of remotion, the treated effluent was not present characteristics for the reuse on the cooling water towers, because its organics load on the raw effluent its too much higher and even with so good levels of remotion, still was necessary a pos treatment to think on reuse. / Este trabalho foi desenvolvido com o objetivo de avaliar o desempenho de três tipos de coagulantes, dois da classe dos PACs (cloreto de polialumínio) e um orgânico, combinados a três classes de polieletrólitos (aniônico, catiônico e não iônico), aplicando o uso de Flotação por Ar Dissolvido (FAD), para viabilizar seu uso em tratamento de efluentes de refinaria de óleo de soja. O experimento foi conduzido em escala de laboratório e primeiramente foram testados os coagulantes em diversas dosagens combinados a diversas faixas de pH e três velocidades ascensionais (Va), encontrando uma faixa ótima dessa combinação para cada uma das três baterias. Para tanto foram fixados parâmetros como tempo e gradiente de mistura rápida (1 min / 150 s-1) tempo e gradiente de mistura lenta (10 min / 40 s-1 5 min / 20 s-1), pressão na câmara de saturação (450 kPa) e razão de recirculação (30%). Encontrando-se a concentração de coagulante ótima (Cc ótima), pH de coagulação ótimo (pHcoag ótimo) e velocidade ascensional ótima (Vaótima). Fixados esses parâmetros foi verificada a variação do polieletrólito, testando-se em diversas dosagens e encontrando uma concentração de floculante ótima (Cf ótimo). Finalmente, com a junção de todos os parâmetros otimizados, efetua-se a variação da razão de recirculação (R) (10, 20 e 30%), escolhendo a melhor R e coletando-se amostras para a determinação dos níveis de turbidez, sólidos suspensos totais (SST), sólidos suspensos voláteis (SSV), óleos e graxas (O&G) e demanda química de oxigênio (DQO) remanescentes no efluente tratado apresentando um grau de remoção de DQO de 95,4%, 93,7% e 95,1% e de O&G de 100%, 94,2% e 99,8% para as baterias 1, 2 e 3 respectivamente. Apesar de serem eficiências excelentes de remoção, o efluente tratado não apresentou características de reuso em torres de resfriamento, pois sua carga orgânica no efluente bruto é muito alta e mesmo com níveis tão bons de remoção ainda seria necessário um pós-tratamento para se avaliar a possibilidade de reuso.
2

Avaliação do desempenho de flotação por ar dissolvido no tratamento de efluente de refinaria de óleo de soja / Valuation of performance of dissolved air flotation on treatment of wastewaters of soybean oil refining

Cecchet, Juliana 06 July 2007 (has links)
Made available in DSpace on 2017-07-10T19:24:01Z (GMT). No. of bitstreams: 1 Juliana Cecchet.pdf: 2090330 bytes, checksum: 58b3febaf50310456ede4d0b8648a7f0 (MD5) Previous issue date: 2007-07-06 / The aim of this work was to value the performance of three types of coagulants, two of them of polichlorate of alum class and one of them was organic, combined to three polyelectrolytes class (anionic, cationic and no ionic) applying the dissolved air flotation (DAF), to viability their use on treatment of effluents of soybean oil refinery. The study was conducted on laboratory scale where first was tested the coagulants on several dosages combined to several bands of pH and three ascension velocities (Va), finding a optimum band of this combination for one of each three batteries. For this, was fixed parameters how time and fast mixed gradient (1 min / 150 s-1), time and slow mixed gradient (10 min / 40 s-1 5 min / 20 s-1), pressure on saturation chamber (450 kPa) and recirculation ratio (30%). Finding the optimum concentration of coagulant (Cc ótima), optimum coagulation pH (pHcoag ótimo) and optimum ascension velocities (Vaótima), fix those parameters and then goes for a variation of polyelectrolyte, testing several dosages and finding a optimum concentrate of polyelectrolyte (Cf ótimo). Finally, with junction of all optimized parameters, was varied de recirculation rate (R) (10, 20 e 30%), choosing the best R and collecting samples for the determination of levels of turbidity, total suspended solids (TSS), volatile suspended solids (VSS), oil and greases (O&G) and chemical oxygen demand (COD) remaining on treated effluent presenting a percentage of remotion COD of 95,4%, 93,7% and 95,1% and O&G of 100%, 94,2% e 99,8% for the batteries 1, 2 e 3 respectively. Despite of being excellent efficiencies of remotion, the treated effluent was not present characteristics for the reuse on the cooling water towers, because its organics load on the raw effluent its too much higher and even with so good levels of remotion, still was necessary a pos treatment to think on reuse. / Este trabalho foi desenvolvido com o objetivo de avaliar o desempenho de três tipos de coagulantes, dois da classe dos PACs (cloreto de polialumínio) e um orgânico, combinados a três classes de polieletrólitos (aniônico, catiônico e não iônico), aplicando o uso de Flotação por Ar Dissolvido (FAD), para viabilizar seu uso em tratamento de efluentes de refinaria de óleo de soja. O experimento foi conduzido em escala de laboratório e primeiramente foram testados os coagulantes em diversas dosagens combinados a diversas faixas de pH e três velocidades ascensionais (Va), encontrando uma faixa ótima dessa combinação para cada uma das três baterias. Para tanto foram fixados parâmetros como tempo e gradiente de mistura rápida (1 min / 150 s-1) tempo e gradiente de mistura lenta (10 min / 40 s-1 5 min / 20 s-1), pressão na câmara de saturação (450 kPa) e razão de recirculação (30%). Encontrando-se a concentração de coagulante ótima (Cc ótima), pH de coagulação ótimo (pHcoag ótimo) e velocidade ascensional ótima (Vaótima). Fixados esses parâmetros foi verificada a variação do polieletrólito, testando-se em diversas dosagens e encontrando uma concentração de floculante ótima (Cf ótimo). Finalmente, com a junção de todos os parâmetros otimizados, efetua-se a variação da razão de recirculação (R) (10, 20 e 30%), escolhendo a melhor R e coletando-se amostras para a determinação dos níveis de turbidez, sólidos suspensos totais (SST), sólidos suspensos voláteis (SSV), óleos e graxas (O&G) e demanda química de oxigênio (DQO) remanescentes no efluente tratado apresentando um grau de remoção de DQO de 95,4%, 93,7% e 95,1% e de O&G de 100%, 94,2% e 99,8% para as baterias 1, 2 e 3 respectivamente. Apesar de serem eficiências excelentes de remoção, o efluente tratado não apresentou características de reuso em torres de resfriamento, pois sua carga orgânica no efluente bruto é muito alta e mesmo com níveis tão bons de remoção ainda seria necessário um pós-tratamento para se avaliar a possibilidade de reuso.

Page generated in 0.0723 seconds